Speed Modulation of the Continuous-Flow Total Artificial Heart to Simulate a Physiologic Arterial Pressure Waveform

被引:35
|
作者
Shiose, Akira [1 ]
Nowak, Kathleen [1 ]
Horvath, David J. [1 ]
Massiello, Alex L. [1 ]
Golding, Leonard A. R. [1 ]
Fukamachi, Kiyotaka [1 ]
机构
[1] Cleveland Clin, Dept Biomed Engn, Lerner Res Inst, Cleveland, OH 44195 USA
基金
美国国家卫生研究院;
关键词
SYSTEM; REPLACEMENT; PULSATILE; BYPASS;
D O I
10.1097/MAT.0b013e3181e650f8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study demonstrated the concept of using speed modulation in a continuous-flow total artificial heart (CFTAH) to shape arterial pressure waveforms and to adjust pressure pulsatility. A programmable function generator was used to determine the optimum pulsatile speed profile. Three speed profiles [sinusoidal, rectangular, and optimized (a profile optimized for generation of a physiologic arterial pressure waveform)] were evaluated using the CFTAH mock circulatory loop. Hemodynamic parameters were recorded at average pump speeds of 2,700 rpm and a modulation cycle of 60 beats per minute. The effects of varying physiologically relevant vascular resistance and lumped compliance on the hemodynamics were assessed. The feasibility of using speed modulation to manipulate systemic arterial pressure waveforms, including a physiologic pressure waveform, was demonstrated in vitro. The additional pump power consumption needed to generate a physiologic pulsatile pressure was 16.2% of the power consumption in nonpulsatile continuous-flow mode. The induced pressure waveforms and pulse pressure were shown to be very responsive to changes in both systemic vascular resistance and arterial compliance. This system also allowed pulsatile pulmonary arterial waveform. Speed modulation in the CFTAH could enable physicians to obtain desired pressure waveforms by simple manual adjustment of speed control input waveforms. ASAIO Journal 2010; 56:403-409.
引用
收藏
页码:403 / 409
页数:7
相关论文
共 50 条
  • [31] Prediction of Optimal Continuous-Flow Total Artificial Heart and Vascular Parameters to Maintain Hemodynamic Homeostasis
    McDowall, Michael T.
    Adair, Paige A.
    Knezek, Sarah F.
    Tuzun, Egemen
    Quick, Christopher M.
    FASEB JOURNAL, 2013, 27
  • [32] Anatomical study of the Cleveland Clinic continuous-flow total artificial heart in adult and pediatric configurations
    Fukamachi, Kiyotaka
    Karimov, Jamshid H.
    Byram, Nicole A.
    Sunagawa, Gengo
    Dessoffy, Raymond
    Miyamoto, Takuma
    Horvath, David J.
    JOURNAL OF ARTIFICIAL ORGANS, 2018, 21 (03) : 383 - 386
  • [33] Initial in vivo Results of Cleveland Clinic Pediatric Continuous-Flow Total Artificial Heart Implant
    Karimov, Jamshid H.
    Horvath, David
    Byram, Nicole
    Sunagawa, Gengo
    Kuban, Barry
    Gao, Shengqiang
    Dessoffy, Raymond
    Fukamachi, Kiyotaka
    CIRCULATION, 2017, 136
  • [34] Anatomical study of the Cleveland Clinic continuous-flow total artificial heart in adult and pediatric configurations
    Kiyotaka Fukamachi
    Jamshid H. Karimov
    Nicole A. Byram
    Gengo Sunagawa
    Raymond Dessoffy
    Takuma Miyamoto
    David J. Horvath
    Journal of Artificial Organs, 2018, 21 : 383 - 386
  • [35] Tsukuba remote monitoring system for continuous-flow artificial heart
    Kosaka, R
    Sankai, Y
    Takiya, R
    Jikuya, T
    Yamane, T
    Tsutsui, T
    ARTIFICIAL ORGANS, 2003, 27 (10) : 897 - 906
  • [36] In vivo acute performance of the Cleveland Clinic self-regulating, continuous-flow total artificial heart
    Fumoto, Hideyuki
    Horvath, David J.
    Rao, Santosh
    Massiello, Alex L.
    Horai, Tetsuya
    Takaseya, Tohru
    Arakawa, Yoko
    Mielke, Nicole
    Chen, Ji-Feng
    Dessoffy, Raymond
    Fukamachi, Kiyotaka
    Golding, Leonard A. R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (01): : 21 - 26
  • [37] Mechanism of Self-Regulation and In Vivo Performance of the Cleveland Clinic Continuous-Flow Total Artificial Heart
    Horvath, David
    Byram, Nicole
    Karimov, Jamshid H.
    Kuban, Barry
    Sunagawa, Gengo
    Golding, Leonard A. R.
    Moazami, Nader
    Fukamachi, Kiyotaka
    ARTIFICIAL ORGANS, 2017, 41 (05) : 411 - 417
  • [38] An innovative, sensorless, pulsatile, continuous-flow total artificial heart: Device design and initial in vitro study
    Fukamachi, Kiyotaka
    Horvath, David J.
    Massietto, Alex L.
    Fumoto, Hideyuki
    Horai, Tetsuya
    Rao, Santosh
    Golding, Leonard A. R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (01): : 13 - 20
  • [39] Simulated Performance of the Cleveland Clinic Continuous-Flow Total Artificial Heart Using the Virtual Mock Loop
    Miyamoto, Takuma
    Horvath, David J.
    Horvath, Dennis W.
    Karimov, Jamshid H.
    Byram, Nicole
    Kuban, Barry D.
    Fukamachi, Kiyotaka
    ASAIO JOURNAL, 2019, 65 (06) : 565 - 572
  • [40] Sensorless Suction Recognition in the Self-Regulating Cleveland Clinic Continuous-Flow Total Artificial Heart
    Horvath, David
    Karimov, Jamshid H.
    Byram, Nicole
    Kuban, Barry
    Golding, Leonard A. R.
    Moazami, Nader
    Fukamachi, Kiyotaka
    ASAIO JOURNAL, 2015, 61 (06) : 726 - 728