Intratidal compliance of the lung and the total respiratory system

被引:0
|
作者
Dzierzawski, Patryk [1 ]
Oswalt, Jakob [1 ]
Wirth, Steffen [1 ]
Schumann, Stefan [1 ]
机构
[1] Univ Freiburg, Med Ctr, Fac Med, Dept Anaesthesiol & Crit Care, Freiburg, Germany
关键词
mechanical ventilation; lung-protective ventilation; dynamical compliance profile; gliding-SLICE-method; END-EXPIRATORY-PRESSURE; TIDAL-VOLUME; VENTILATION; MECHANICS; INJURY;
D O I
10.1088/1361-6579/ac8e4d
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective. The worldwide rising quantity of surgeries and the corresponding need of mechanical ventilation means a rising number of patients are at risk of suffering from post-operative pulmonary complications. To prevent this risk, individual mechanics of the lung should be considered when setting the parameters of mechanical ventilation. Intratidal compliance analysis based on transpulmonal pressure would provide an estimate for individual lung mechanics. The downside of such measure, however, is its invasiveness. Accurate measurement requires recording of the esophageal pressure as surrogate for the actual pleural pressure. Measuring pressure at the airway opening is considerably easier, but the resulting mechanics of the respiratory system may not represent the actual lung mechanics in a straightforward fashion. Approach. In order to evaluate if the mechanics of the lungs are represented by analysis of the mechanics of the respiratory system we determined intratidal dynamic compliance-volume profiles of both in 23 lung-healthy mechanically ventilated patients undergoing elective surgery. We also compared the accuracy of the compliance profiles resulting from analysis of the total breath with those resulting from the analysis of inspiration data only. Main results. When the whole breath was analyzed 54.3%, and with only inspiration data 69.6%, of compliance profiles of the respiratory system matched those of the lung. With both approaches profiles of the lung and the respiratory system matched or deviated by only one neighboring step (75% whole breath, 91.3% inspiration only), and never contradicted each other. Significance. Compliance profiles calculated from volume and pressure data of the respiratory system are an adequate surrogate for the compliance profiles of the lungs of lung-healthy patients. Therefore, invasive assessment of esophageal pressure for achievement of intrapleural pressure is unnecessary. The compliance profiles based on only inspiratory data appear more sensitive for indicating intratidal derecruitment than those based on data of the whole breath.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] MEASUREMENT OF TOTAL RESPIRATORY-SYSTEM COMPLIANCE IN THE HEALTHY NEWBORN AND THE EFFECT OF RESPIRATORY-DISTRESS
    MIGDAL, M
    DREIZZEN, E
    PRAUD, JP
    DEHAN, M
    VIAL, M
    GAULTIER, C
    ARCHIVES FRANCAISES DE PEDIATRIE, 1987, 44 (03): : 227 - 227
  • [22] REFERENCING LUNG-VOLUME FOR MEASUREMENTS OF RESPIRATORY SYSTEM COMPLIANCE IN INFANTS
    MORTOLA, JP
    HEMMINGS, G
    MATSUOKA, T
    SAIKI, C
    FOX, G
    PEDIATRIC PULMONOLOGY, 1993, 16 (04) : 248 - 253
  • [23] Respiratory System Compliance Accurately Assesses the "Baby Lung" in Pediatric Acute Respiratory Distress Syndrome
    Cruces, Pablo
    Reveco, Sonia
    Caviedes, Paola
    Diaz, Franco
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209 (07) : 890 - 893
  • [24] THE TOTAL COMPLIANCE OF THE RESPIRATORY SYSTEM DURING THE 1ST YEAR OF LIFE
    THOMSON, AH
    BEARDSMORE, CS
    SILVERMAN, M
    BULLETIN EUROPEEN DE PHYSIOPATHOLOGIE RESPIRATOIRE-CLINICAL RESPIRATORY PHYSIOLOGY, 1985, 21 (05): : 411 - 416
  • [25] A NEW METHOD FOR CALCULATING TOTAL RESPIRATORY SYSTEM COMPLIANCE - THEORY AND MODEL EXPERIMENTS
    DAROWSKI, M
    RUDOWSKI, R
    RAWICZ, M
    HEDENSTIERNA, G
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1985, 29 (04) : 395 - 399
  • [26] MEASURING PASSIVE COMPLIANCE OF THE TOTAL RESPIRATORY SYSTEM IN NEWBORNS FOLLOWING CESAREAN DELIVERY
    DREIZZEN, E
    MIGDAL, M
    BENLABED, M
    VIAL, M
    ESCOURROU, P
    GAULTIER, C
    ARCHIVES FRANCAISES DE PEDIATRIE, 1988, 45 (01): : 72 - 72
  • [27] SIMPLE METHOD OF MEASURING TOTAL RESPIRATORY SYSTEM COMPLIANCE IN NEWBORN-INFANTS
    OLINSKY, A
    BRYAN, AC
    BRYAN, MH
    SOUTH AFRICAN MEDICAL JOURNAL, 1976, 50 (05): : 128 - 130
  • [28] TOTAL RESPIRATORY SYSTEM COMPLIANCE, CRS, IN NORMAL INFANTS - COMPARISON OF 2 APPARATII
    BARYISHAY, E
    MCCOY, KS
    FILBRUN, DA
    PEDIATRIC RESEARCH, 1991, 29 (04) : A367 - A367
  • [29] PASSIVE COMPLIANCE OF THE TOTAL RESPIRATORY SYSTEM IN NEWBORNS AFTER CESAREAN-SECTION
    DREIZZEN, E
    MIGDAL, M
    BENLABED, M
    HAMZA, J
    ESCOURROU, P
    ECOFFEY, E
    VIAL, M
    GAULTIER, CL
    ARCHIVES FRANCAISES DE PEDIATRIE, 1990, 47 (09): : 633 - 636
  • [30] COMPLIANCE OF THE TOTAL RESPIRATORY SYSTEM IN HEALTHY PRETERM AND FULL-TERM NEWBORNS
    MIGDAL, M
    DREIZZEN, E
    PRAUD, JP
    VIAL, M
    DEHAN, M
    CHAMBILLE, B
    GAULTIER, C
    PEDIATRIC PULMONOLOGY, 1987, 3 (04) : 214 - 218