Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT

被引:278
|
作者
Kachelriess, M
Watzke, O
Kalender, WA
机构
[1] Institute of Medical Physics, University of Erlangen-Nürnberg, Erlangen
关键词
computed tomography (CT); multi-slice spiral CT (MSCT); cone-beam CT (CBCT); artifact reduction; noise reduction; dose reduction; adaptive filters;
D O I
10.1118/1.1358303
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In modern computed tomography (CT) there is a strong desire to reduce patient dose and/or to improve image quality by increasing spatial resolution and decreasing image noise. These are conflicting demands since increasing resolution at a constant noise level or decreasing noise at a constant resolution level implies a higher demand on x-ray power and an increase of patient dose. X-ray tube power is limited due to technical reasons. We therefore developed a generalized multi-dimensional adaptive filtering approach that applies nonlinear filters in up to three dimensions in the raw data domain. This new method differs from approaches in the literature since our nonlinear filters are applied not only in the detector row direction but also in the view and in the z-direction. This true three-dimensional filtering improves the quantum statistics of a measured projection Value proportional to the third power of the filter size. Resolution tradeoffs are shared among these three dimensions and thus are considerably smaller as compared to one-dimensional smoothing approaches. Patient data of spiral and sequential single- and multi-slice CT scans as well as simulated spiral cone-beam data were processed to evaluate these new approaches. Image quality was assessed by evaluation of difference images, by measuring the image noise and the noise reduction, and by calculating the image resolution using point spread functions. The use of generalized adaptive filters helps to reduce image noise or, alternatively, patient dose. Image noise structures, typically along the direction of the highest attenuation, are effectively reduced. Noise reduction values of typically 30%-60% can be achieved in noncylindrical body regions like the shoulder. The loss in image resolution remains below 5% for all cases. In addition, the new method has a great potential to reduce metal artifacts, e.g., in the hip region. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:475 / 490
页数:16
相关论文
共 50 条
  • [1] Advanced single-slice rebinning in cone-beam spiral CT
    Kachelriess, M
    Schaller, S
    Kalender, WA
    MEDICAL PHYSICS, 2000, 27 (04) : 754 - 772
  • [2] Advanced single-slice rebinning for tilted spiral cone-beam CT
    Kachelriess, M
    Fuchs, T
    Schaller, S
    Kalender, WA
    MEDICAL PHYSICS, 2001, 28 (06) : 1033 - 1041
  • [3] Dynamic Bowtie Filter for Cone-Beam/Multi-Slice CT
    Liu, Fenglin
    Yang, Qingsong
    Cong, Wenxiang
    Wang, Ge
    PLOS ONE, 2014, 9 (07):
  • [4] Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey
    G. Brix
    H. D. Nagel
    G. Stamm
    R. Veit
    U. Lechel
    J. Griebel
    M. Galanski
    European Radiology, 2003, 13 : 1979 - 1991
  • [5] Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey
    Brix, G
    Nagel, HD
    Stamm, G
    Veit, R
    Lechel, U
    Griebel, J
    Galanski, M
    EUROPEAN RADIOLOGY, 2003, 13 (08) : 1979 - 1991
  • [6] A comparison of jaw dimensional and quality assessments of bone characteristics with cone-beam CT, spiral tomography, and multi-slice spiral CT
    Loubele, Miet
    Guerrero, Maria Eugenia
    Jacobs, Reinhilde
    Suetens, Paul
    van Steenberghe, Daniel
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (03) : 446 - 454
  • [7] Three-dimensional cephalometry: Spiral multi-slice vs cone-beam computed tomography
    Swennen, Gwen R. J.
    Schutyser, Filip
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2006, 130 (03) : 410 - 416
  • [8] Single-slice rebinning method for helical cone-beam CT
    Noo, F
    Defrise, M
    Clackdoyle, R
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (02): : 561 - 570
  • [9] Single-slice rebinning reconstruction in spiral cone-beam computed tomography
    Bruder, H
    Kachelriess, M
    Schaller, S
    Stierstorfer, K
    Flohr, T
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (09) : 873 - 887
  • [10] Slice sensitivity profiles and pixel noise of multi-slice CT in comparison with single-slice CT.
    Schorn, C
    Obenauer, S
    Funke, M
    Hermann, KP
    Kopka, L
    Grabbe, E
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 171 (03): : 219 - 225