Composite beams with partial fire protection

被引:19
|
作者
Wang, YC [1 ]
机构
[1] Bldg Res Estab, Struct Design Div, Watford WD2 7JR, England
关键词
D O I
10.1016/S0379-7112(97)00000-3
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results of a theoretical investigation into the effectiveness of a novel way to significantly reduce the fire protection cost to a composite beam. In this method, only the steel lower flange and a fraction of the steel web ave protected. The effectiveness of a partially protected composite beam is assessed by comparing its plastic moment capacity with that of a fully protected beam subject to both the standard fire exposure and design fires. The parametric time-temperature curves in Eurocode 1 are used to determine the time-temperature relationships of design fires. A finite element analysis computer program for hear transfer is used to evaluate the temperature field in the composite cross-section. The plastic moment capacity is calculated by dividing the composite cross-section into many small blocks and summing their contributions. Partial protection is suitable for situations where the protection is applied along the steel profile. Results fr om this study indicate that the total fire protection cost may be reduced considerably due to more than 50% reduction in the protected surface area, despite similar material costs. (C) 1998 Building Research Establishment. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:315 / 332
页数:18
相关论文
共 50 条
  • [31] Analytical prediction of composite beams response in fire situations
    Benedetti, Andrea
    Mangoni, Enrico
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2007, 63 (02) : 221 - 228
  • [32] Fire Resistance of Composite Beams with Restrained Superposed Slabs
    Lyu, Junli
    Chen, Qichao
    Xue, Huizhong
    Cai, Yongyuan
    Lyu, Jingjing
    Zhou, Shengnan
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2020, 2020
  • [33] Fire analysis of timber composite beams with interlayer slip
    Schnabl, S.
    Planinc, I.
    Turk, G.
    Srpcic, S.
    FIRE SAFETY JOURNAL, 2009, 44 (05) : 770 - 778
  • [34] The fire resistance of lightweight composite tanks depending on fire protection systems
    Poetzsch, Sina
    Krueger, Simone
    Sklorz, Christian
    Borch, Joerg
    Hilse, Thilo
    Otremba, Frank
    FIRE SAFETY JOURNAL, 2018, 100 : 118 - 127
  • [35] The partial fire protection of steel members: a comparative study
    Sejna, Jakub
    Dobrovolny, Patrik
    Wald, Frantisek
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2023, 14 (04) : 575 - 597
  • [36] FIRE ASSESSMENT OF STEEL BEAM MEMBERS WITH PARTIAL PASSIVE FIRE PROTECTION COVERAGE
    Smith, Hunter
    Ayhan, Yavuz
    Sari, Ali
    INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 8, 2012, : 437 - 446
  • [37] Intumescent fire protection coating thickness for shallow floor beams
    Sha, W
    Chan, TM
    ADVANCES IN BUILDING TECHNOLOGY, VOLS I AND II, PROCEEDINGS, 2002, : 1321 - +
  • [38] Fe analysis of continuous composite beams with partial interaction
    Fan Jiansheng
    Nie Jianguo
    8th International Conference on Steel-Concrete Composite and Hybrid Structures, Proceedings, 2006, : 475 - 481
  • [39] PARTIAL-INTERACTION DESIGN OF COMPOSITE BEAMS.
    Johnson, R.P.
    May, I.M.
    1600, (53):
  • [40] Dynamic analysis of partial-interaction composite beams
    Shen, Xudong
    Chen, Weiqiu
    Wu, Yufei
    Xu, Rongqiao
    COMPOSITES SCIENCE AND TECHNOLOGY, 2011, 71 (10) : 1286 - 1294