Assessment of the radiation dose associated with X-ray examinations using the DoseCal and CALDose_X software packages

被引:0
|
作者
Saeed, M. K. [1 ]
Almalki, Y. [2 ]
机构
[1] Najran Univ, Appl Med Sci Coll, Dept Radiol Sci, Najran, Saudi Arabia
[2] Najran Univ, Div Radiol, Coll Med, Najran, Saudi Arabia
来源
关键词
Pelvis; skull; DoseCal; CALDose_X; DIAGNOSTIC REFERENCE LEVELS; ROUTINE DIGITAL RADIOGRAPHY; ENTRANCE SURFACE; CANCER-RISK; PATIENT; DOSIMETRY; ADULT; ESTABLISHMENT; RADIOLOGY; ORGAN;
D O I
10.52547/ijrr.20.1.29
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The aim of this study was to estimate the entrance skin dose (ESD) in adult patients undergoing skull and pelvis X-ray examinations in Najran, Saudi Arabia England) and CALDose_X (Department of Nuclear Energy, Federal University of comparisons between these two software packages and against international reference dose levels and estimating the radiogenic risk during X-ray examinations. Materials and Methods: A dataset of 410 patients seen at Najran University Hospital was examined to assess the radiation dose using the DoseCal and CALDose_X software packages. Results: The values of the entrance dose, organ doses and effective dose obtained by the DoseCal and CALDose_X software were reported in this study. The ESD values estimated from the X-ray units ranged from 0.32 to 2.65 mGy for skull anteroposterior/posteroanterior (AP/PA), 0.62 to 2.13 mGy for skull lateral (LAT), and 1.23 to 3.15 mGy for pelvis AP projection. According to the DoseCal and CALDose_X, the dose absorbed by the pelvis and skull varied by a factor ranging between 1.2 and 2.4. Conclusion: All entrance doses calculated for the skull and pelvis were found to be within the corresponding dose reference levels recommended by the international agency, board and commission highlighted in this study.
引用
收藏
页码:191 / 197
页数:7
相关论文
共 50 条
  • [21] Embryo/Fetus Radiation Dose and Risk from Dual X-ray Absorptiometry Examinations
    J. Damilakis
    K. Perisinakis
    H. Vrahoriti
    G. Kontakis
    H. Varveris
    N. Gourtsoyiannis
    [J]. Osteoporosis International, 2002, 13 : 716 - 722
  • [22] THYROID RADIATION-DOSE DURING PANORAMIC AND CEPHALOMETRIC DENTAL X-RAY EXAMINATIONS
    BLOCK, AJ
    GOEPP, RA
    MASON, EW
    [J]. ANGLE ORTHODONTIST, 1977, 47 (01) : 17 - 24
  • [23] ESTIMATING RADIATION DOSE TO MAJOR ORGANS IN DENTAL X-RAY EXAMINATIONS: A PHANTOM STUDY
    Li, Yong
    Huang, Bingsheng
    Cao, Jun
    Fang, Tianqi
    Liu, Guoqing
    Li, Xuguang
    Wu, Jiabao
    [J]. RADIATION PROTECTION DOSIMETRY, 2020, 192 (03) : 328 - 334
  • [24] Embryo/fetus radiation dose and risk from dual X-ray absorptiometry examinations
    Damilakis, J
    Perisinakis, K
    Vrahoriti, H
    Kontakis, G
    Varveris, H
    Gourtsoyiannis, N
    [J]. OSTEOPOROSIS INTERNATIONAL, 2002, 13 (09) : 716 - 722
  • [25] Novel pregnant model phantoms for measurement of foetal radiation dose in x-ray examinations
    Matsunaga, Yuta
    Haba, Tomonobu
    Kobayashi, Masanao
    Suzuki, Shoichi
    Asada, Yasuki
    Chida, Koichi
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2021, 41 (03) : N12 - N21
  • [26] Radiation exposure of auxiliary persons during high dose X-ray examinations of horses
    Busse, Constance
    Luepke, Matthias
    Stadler, Peter
    Geburek, Florian
    Seifert, Hermann
    [J]. PFERDEHEILKUNDE, 2008, 24 (03): : 428 - 432
  • [27] Assessment of Patient Radiation Dose during Conventional Diagnostic X-ray Examinations in Three Public Hospitals in Northern Jordan using TLDs
    Ababneh, Zaid Q.
    Ababneh, Anas M.
    Hani, Majd S. Bani
    Ababneh, Riad S.
    Aljarrah, Khaled M.
    [J]. HEALTH PHYSICS, 2020, 118 (06): : 593 - 599
  • [28] REDUCTION OF DOSE IN PELVIC EXAMINATIONS OF INFANTS USING MODERN X-RAY TECHNIQUES
    KALENDER, W
    REITHER, M
    SCHUSTER, W
    [J]. PEDIATRIC RADIOLOGY, 1979, 8 (04) : 233 - 235
  • [29] Fukushima radiation dose was equivalent to X-ray
    不详
    [J]. NEW SCIENTIST, 2017, 234 (3125) : 19 - 19
  • [30] UK population dose from medical X-ray examinations
    Hart, D
    Wall, BF
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2004, 50 (03) : 285 - 291