On the press fit of a crankpin into a circular web in pressed-up crankshafts

被引:7
|
作者
Strozzi, A [1 ]
Vaccari, P [1 ]
机构
[1] Univ Modena, Dipartimento Ingn Meccan, I-41100 Modena, Italy
来源
关键词
press fit; crankweb; crankpin; contact stresses; finite elements;
D O I
10.1243/030932403765310527
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The contact stresses induced by press-fitting a crankpin into a crankweb bore in pressed-up crankshafts are analysed for crankwebs possessing a circular geometry. The three-dimensional nature of this problem is reduced to a plane model, where the crankweb is described in terms of an eccentrically bored disc of uniform thickness, while the crankpin is idealized as an annular ring. Two different approaches are employed. Firstly, an elastic plane finite element analysis is carried out for this contact problem. Secondly, based upon the results of the numerical study, three variously approximated plane analytical models are developed. The contact pressure and the circumferential stress by the web bore are investigated, as well as the transmissible torque, where normalized diagrams are provided exploring a variety of disc-type crankweb geometries. Finally, selected three-dimensional finite element results are discussed, which highlight the limits of a plane model.
引用
收藏
页码:189 / 199
页数:11
相关论文
共 50 条
  • [1] Transducer Torque Control System of the Web Wind-up Tension in Gravure Press
    Wu, Qiumin
    Zhang, Hanxiao
    Wu, Jimei
    [J]. ADVANCED GRAPHIC COMMUNICATIONS AND MEDIA TECHNOLOGIES, 2017, 417 : 775 - 781
  • [2] Early follow-up of a custom non-fluted diaphyseal press-fit tumour prosthesis
    O'Donnell, Patrick W.
    Griffin, Anthony M.
    Eward, William C.
    Sternheim, Amir
    Wunder, Jay S.
    Ferguson, Peter C.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2014, 38 (01) : 123 - 127
  • [3] Press fit condylar total knee arthroplasty: Radiographic evaluation at a 5-year follow-up
    Sandrucci G.
    Cenna E.
    Favuto M.
    Bistolfi A.
    Crova M.
    [J]. Journal of Orthopaedics and Traumatology, 2002, 3 (3) : 157 - 162
  • [4] A prospective 24 months follow-up of a three component press-fit prosthesis for hallux rigidus
    Wassink, S.
    Burger, B. J.
    Saragas, N. P.
    Marquez, J. Asuncion
    Trtik, L.
    Harlaar, J.
    [J]. FOOT AND ANKLE SURGERY, 2017, 23 (03) : 157 - 162
  • [5] Early follow-up of a custom non-fluted diaphyseal press-fit tumour prosthesis
    Patrick W. O’Donnell
    Anthony M. Griffin
    William C. Eward
    Amir Sternheim
    Jay S. Wunder
    Peter C. Ferguson
    [J]. International Orthopaedics, 2014, 38 : 123 - 127
  • [6] Press-Fit Condylar design total knee arthroplasty - Fourteen to seventeen-year follow-up
    Rodricks, David J.
    Patil, Shantanu
    Pulido, Pamela
    Colwell, Clifford W., Jr.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (01): : 89 - 95
  • [7] CEMENTLESS PRESS-FIT CUP - PRINCIPLES, EXPERIMENTAL-DATA, AND 3-YEAR FOLLOW-UP-STUDY
    MORSCHER, E
    BEREITER, H
    LAMPERT, C
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1989, (249) : 12 - 20
  • [8] Press-Fit Condylar total knee arthroplasty - 5- to 9-year follow-up evaluation
    Martin, SD
    McManus, JL
    Scott, RD
    Thornhill, TS
    [J]. JOURNAL OF ARTHROPLASTY, 1997, 12 (06): : 603 - 614
  • [9] Early failure of smooth hydroxyapatite-coated press-fit acetabular cup - 7 years of follow-up
    Cheung, KW
    Yung, SH
    Wong, KC
    Chiu, KH
    [J]. JOURNAL OF ARTHROPLASTY, 2005, 20 (05): : 627 - 631
  • [10] Anatomic Monopolar Press-fit Radial Head Arthroplasty; High Rate of Loosening at Mid-Term Follow Up
    Samra, Inderpaul
    Kwaees, Tariq A.
    Mati, Wael
    Blundell, Clare
    Lane, Suzanne
    Harrison, John W. K.
    Charalambous, Charalambos P.
    [J]. SHOULDER & ELBOW, 2023, 15 (02) : 207 - 217