Anatomic Monopolar Press-fit Radial Head Arthroplasty; High Rate of Loosening at Mid-Term Follow Up

被引:2
|
作者
Samra, Inderpaul [1 ]
Kwaees, Tariq A. [1 ]
Mati, Wael [2 ]
Blundell, Clare [1 ]
Lane, Suzanne [1 ]
Harrison, John W. K. [3 ]
Charalambous, Charalambos P. [1 ,4 ,5 ]
机构
[1] Blackpool Victoria Hosp, Dept Orthopaed, Whinney Heys Rd, Blackpool FY38NR, Lancs, England
[2] Blackpool Victoria Hosp, Dept Radiol, Whinney Heys Rd, Blackpool FY38NR, Lancs, England
[3] Gateshead Hlth NHS Fdn Trust, Queen Elizabeth Ave, Gateshead NE9, Durham, England
[4] Univ Cent Lancashire, Sch Med, Fylde Rd, Preston PR12HE, Lancs, England
[5] Blackpool Teaching Hosp NHS Fdn Trust, Whinney Heys Rd, Blackpool FY38NR, Lancs, England
关键词
radial head arthroplasty; radial head fractures; elbow instability; PROSTHETIC DESIGN; BONE-RESORPTION; TERRIBLE TRIAD; HIP STEMS; INJURIES; OUTCOMES; REPLACEMENT; EXCISION; IMPLANT; SMOOTH;
D O I
10.1177/17585732221080768
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionRadial head arthroplasty (RHA) is used for the management of unstable or unreconstructable injuries of the radial head. Our aim was to investigate clinical and radiographic outcomes in patients treated with the Acumed anatomic radial head press-fit system for trauma.MethodsClinical and radiographic assessment of RHAs undertaken for trauma with minimum 2-year follow-up.Results16 consecutive patients, mean age 53 (21-82) and 66 month +/- 27 (26-122) clinical follow-up were included. There were marked radiographic changes with 11/16 showing periprosthetic lucent lines and 13/16 showing subcollar osteolysis. Radiographic changes occurred early post-surgery. Stem loosening was associated with larger cantilever quotients (0.47 vs 0.38, p = 0.004). Overall survivability was 81.2%, with 3 RHAs removed. Clinical outcomes for the retained RHAs were acceptable with mean flexion 134 degrees, extension deficit of 10 degrees, pronation of 82 degrees, and supination of 73 degrees. Mean VAS scores were 8.5 +/- 14.4, QuickDASH 13.8 +/- 18.9, Mayo Elbow Performance Scores were 91.5 +/- 12.5 with no poor scores.ConclusionMid-term clinical functional outcomes following the Acumed anatomic RHA are acceptable in most cases. However, in view of the extensive periprosthetic lucencies and surgical removal due to loosening, patients should be cautioned when consented for implantation of the prosthesis, especially if a large collar is anticipated.
引用
收藏
页码:207 / 217
页数:11
相关论文
共 50 条
  • [1] Short- to mid-term results of metallic press-fit radial head arthroplasty in unstable injuries of the elbow
    Flinkkila, T.
    Kaisto, T.
    Sirnio, K.
    Hyvonen, P.
    Leppilahti, J.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (06): : 805 - 810
  • [2] Outcomes and radiographic findings of anatomic press-fit radial head arthroplasty
    Levy, Jonathan C.
    Formaini, Nathan T.
    Kurowicki, Jennifer
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (05) : 802 - 809
  • [3] Stress Shielding around Press-Fit Radial Head Arthroplasty: Proposal for a New Classification System Based on the Analysis of 97 Patients with a Mid-Term Follow-Up and a Review of the Literature
    Giannicola, Giuseppe
    Amura, Andrea
    Prigent, Sebastien
    Zoccali, Carmine
    Sessa, Pasquale
    HEALTHCARE, 2024, 12 (03)
  • [4] Radiographic and clinical comparisons between loose-fit and press-fit stems in monopolar radial head arthroplasty for comminuted radial head fractures
    Shimura, Haruhiko
    Wakabayashi, Yoshiaki
    Yamada, Tetsuya
    Shirakawa, Ken
    Sato, Tetsuya
    Fujita, Koji
    Niizeki, Yumi
    Suzuki, Shiro
    Kaburagi, Hidetoshi
    Suzuki, Hidetsugu
    Nimura, Akimoto
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2025, 30 (01) : 147 - 151
  • [5] Press-fit bipolar radial head arthroplasty, midterm results
    Kodde, Izaak F.
    Heijink, Andras
    Kaas, Laurens
    Mulder, Paul G. H.
    van Dijk, C. Niek
    Eygendaal, Denise
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (08) : 1235 - 1242
  • [6] Outcomes of press-fit radial head arthroplasty following complex radial head fractures
    Lobo-Escolar, Luis
    Abellan-Miralles, Cesar
    Escola-Benet, Anna
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (02)
  • [7] Outcomes of press-fit radial head arthroplasty in unconstructable radial head fractures with associated elbow injuries: An average 5-year follow up
    Eyre-Brook, A., I
    Kankanalu, P.
    Majkowski, L.
    Zreik, N.
    Jones, V
    Thyagarajan, D. S.
    Ali, A. A.
    Booker, S. J.
    SHOULDER & ELBOW, 2024,
  • [8] Anatomic versus reverse shoulder arthroplasty: a mid-term follow-up comparison
    Schoch, Bradley S.
    King, Joseph J.
    Zuckerman, Joseph
    Wright, Thomas W.
    Roche, Chris
    Flurin, Pierre-Henri
    SHOULDER & ELBOW, 2021, 13 (05) : 518 - 526
  • [9] Early aseptic loosening of a press-fit radial head prosthesis - A case series of 6 patients
    Corbaz, J.
    Barimani, B.
    Vauclair, F.
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2023, 51 (04)
  • [10] Survivorship of anatomic press-fit short-stem radial head replacement with a pyrocarbon bearing
    Viswanath, Aparna I.
    Watts, Adam C.
    SHOULDER & ELBOW, 2022, 14 (04) : 426 - 433