Optimal diffusion weighting for in vivo cardiac diffusion tensor imaging

被引:47
|
作者
Scott, Andrew D. [1 ,2 ]
Ferreira, Pedro F. A. D. C. [1 ,2 ]
Nielles-Vallespin, Sonia [1 ,3 ]
Gatehouse, Peter [1 ,2 ]
McGill, Laura-Ann [1 ,2 ]
Kilner, Philip [1 ,2 ]
Pennell, Dudley J. [1 ,2 ]
Firmin, David N. [1 ,2 ]
机构
[1] Royal Brompton Hosp, NIHR Cardiovasc Biomed Res Unit, London SW3 6NP, England
[2] Univ London Imperial Coll Sci Technol & Med, Natl Heart & Lung Inst, London, England
[3] NHLBI, NIH, Bethesda, MD 20892 USA
关键词
DTI; diffusion weighting; b-value; cardiac diffusion; microvascular perfusion; MAGNETIC-RESONANCE; HYPERTROPHIC CARDIOMYOPATHY; MYOCARDIAL MICROSTRUCTURE; WATER DIFFUSION; B-VALUE; MRI; STRAIN; MOTION; NOISE; HEART;
D O I
10.1002/mrm.25418
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo investigate the influence of the diffusion weighting on in vivo cardiac diffusion tensor imaging (cDTI) and obtain optimal parameters. MethodsTen subjects were scanned using stimulated echo acquisition mode echo planar imaging with six b-values, from 50 to 950 smm(-2), plus b=15 smm(-2) reference. The relationship between b-value and both signal loss and signal-to-noise ratio measures was investigated. Mean diffusivity, fractional anisotropy, and helical angle maps were calculated using all possible b-value pairs to investigate the effects of diffusion weighting on the main and reference data. ResultsSignal decay at low b-values was dominated by processes with high apparent diffusion coefficients, most likely microvascular perfusion. This effect could be avoided by diffusion weighting of the reference images. Parameter maps were improved with increased b-value until the diffusion-weighted signal approached the noise floor. For the protocol used in this study, b=750 smm(-2) combined with 150 smm(-2) diffusion weighting of the reference images proved optimal. ConclusionMean diffusivity, fractional anisotropy, and helical angle from cDTI are influenced by the b-value of the main and reference data. Using optimal values improves parameter maps and avoids microvascular perfusion effects. This optimized protocol should provide greater sensitivity to pathological changes in parameter maps. Magn Reson Med 74:420-430, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:420 / 430
页数:11
相关论文
共 50 条
  • [32] Effects of cardiac pulsation in diffusion tensor imaging of the rat brain
    Kim, Sungheon
    Pickup, Stephen
    Poptani, Harish
    JOURNAL OF NEUROSCIENCE METHODS, 2010, 194 (01) : 116 - 121
  • [33] Comparison of three denoising methods for cardiac diffusion tensor imaging
    Xu, Xi
    Liu, Shengping
    Guo, Muzi
    Zhu, Yanjie
    Chen, Rui
    Yang, Yuxin
    2020 5TH INTERNATIONAL CONFERENCE ON MECHANICAL, CONTROL AND COMPUTER ENGINEERING (ICMCCE 2020), 2020, : 2350 - 2353
  • [34] Cardiac fiber orientation in goat measured with diffusion tensor imaging
    Geerts-Ossevoort, Liesbeth
    Bovendeerd, Peter
    Nicolay, Klaas
    Arts, Theo
    2000, Am Inst Phys, Woodbury, NY, United States (28)
  • [35] Editorial for "Optimal Diffusion Gradient Encoding Scheme for Diffusion Tensor Imaging Based on Golden Ratio"
    Cruciata, Giuseppe
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (05) : 1582 - 1583
  • [36] In vivo diffusion tensor imaging of rat spinal cord with echo planar imaging
    Fenyes, DA
    Narayana, PA
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (02) : 300 - 306
  • [37] Comparison of interpolation methods of predominant cardiomyocyte orientation from in vivo and ex vivo cardiac diffusion tensor imaging data
    Stimm, Johanna
    Guenthner, Christian
    Kozerke, Sebastian
    Stoeck, Christian T.
    NMR IN BIOMEDICINE, 2022, 35 (05)
  • [38] Early Identification of Myocardial Microstructural Alterations in Hypertrophic Cardiomyopathy with in Vivo Cardiac Diffusion-Tensor Imaging
    Dong, Zhixiang
    Tang, Yun
    Sun, Peng
    Yin, Gang
    Zhao, Kankan
    Ma, Xuan
    Yang, Shujuan
    Wang, Jiaxin
    Xiang, Xiaorui
    Yang, Kai
    Lu, Minjie
    Chen, Xiuyu
    Zhu, Yanjie
    Zhao, Shihua
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2025, 7 (01):
  • [39] Motion-compensated b-tensor encoding for in vivo cardiac diffusion-weighted imaging
    Lasic, Samo
    Szczepankiewicz, Filip
    Dall'Armellina, Erica
    Das, Arka
    Kelly, Christopher
    Plein, Sven
    Schneider, Jurgen E.
    Nilsson, Markus
    Teh, Irvin
    NMR IN BIOMEDICINE, 2020, 33 (02)
  • [40] Cardiac Diffusion Tensor Biomarkers of Chronic Infarction Based on In Vivo Data
    Rahman, Tanjib
    Moulin, Kevin
    Perotti, Luigi E.
    APPLIED SCIENCES-BASEL, 2022, 12 (07):