Optimal diffusion weighting for in vivo cardiac diffusion tensor imaging

被引:47
|
作者
Scott, Andrew D. [1 ,2 ]
Ferreira, Pedro F. A. D. C. [1 ,2 ]
Nielles-Vallespin, Sonia [1 ,3 ]
Gatehouse, Peter [1 ,2 ]
McGill, Laura-Ann [1 ,2 ]
Kilner, Philip [1 ,2 ]
Pennell, Dudley J. [1 ,2 ]
Firmin, David N. [1 ,2 ]
机构
[1] Royal Brompton Hosp, NIHR Cardiovasc Biomed Res Unit, London SW3 6NP, England
[2] Univ London Imperial Coll Sci Technol & Med, Natl Heart & Lung Inst, London, England
[3] NHLBI, NIH, Bethesda, MD 20892 USA
关键词
DTI; diffusion weighting; b-value; cardiac diffusion; microvascular perfusion; MAGNETIC-RESONANCE; HYPERTROPHIC CARDIOMYOPATHY; MYOCARDIAL MICROSTRUCTURE; WATER DIFFUSION; B-VALUE; MRI; STRAIN; MOTION; NOISE; HEART;
D O I
10.1002/mrm.25418
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo investigate the influence of the diffusion weighting on in vivo cardiac diffusion tensor imaging (cDTI) and obtain optimal parameters. MethodsTen subjects were scanned using stimulated echo acquisition mode echo planar imaging with six b-values, from 50 to 950 smm(-2), plus b=15 smm(-2) reference. The relationship between b-value and both signal loss and signal-to-noise ratio measures was investigated. Mean diffusivity, fractional anisotropy, and helical angle maps were calculated using all possible b-value pairs to investigate the effects of diffusion weighting on the main and reference data. ResultsSignal decay at low b-values was dominated by processes with high apparent diffusion coefficients, most likely microvascular perfusion. This effect could be avoided by diffusion weighting of the reference images. Parameter maps were improved with increased b-value until the diffusion-weighted signal approached the noise floor. For the protocol used in this study, b=750 smm(-2) combined with 150 smm(-2) diffusion weighting of the reference images proved optimal. ConclusionMean diffusivity, fractional anisotropy, and helical angle from cDTI are influenced by the b-value of the main and reference data. Using optimal values improves parameter maps and avoids microvascular perfusion effects. This optimized protocol should provide greater sensitivity to pathological changes in parameter maps. Magn Reson Med 74:420-430, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:420 / 430
页数:11
相关论文
共 50 条
  • [1] In vivo cardiac diffusion tensor imaging in free-breathing conditions
    Hongjiang Wei
    Magalie Viallon
    Benedicte M Delattre
    Vinay M Pai
    Han Wen
    Hui Xue
    Christoph Guetter
    Marie-Pierre Jolly
    Pierre Croisille
    Yuemin Zhu
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [2] Characterizing cardiac involvement in amyloidosis using in-vivo cardiac diffusion tensor imaging
    Gotschy, A.
    Von Deuster, C.
    Van Gorkum, R. J. H.
    Gastl, M.
    Vintschger, E.
    Flammer, A. J.
    Manka, R.
    Stoeck, C. T.
    Kozerke, S.
    EUROPEAN HEART JOURNAL, 2018, 39 : 877 - 877
  • [3] Diffusion tensor MR imaging of the brain: Effect of diffusion weighting on trace and anisotropy measurements
    Melhem, ER
    Itoh, R
    Jones, L
    Barker, PB
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2000, 21 (10) : 1813 - 1820
  • [4] In vivo diffusion tensor imaging of the human prostate
    Sinha, S
    Sinha, U
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (03) : 530 - 537
  • [5] Optimal Diffusion Tensor Imaging with Repeated Measurements
    Alipoor, Mohammad
    Gu, Irene Yu Hua
    Mehnert, Andrew J. H.
    Lilja, Ylva
    Nilsson, Daniel
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION (MICCAI 2013), PT I, 2013, 8149 : 687 - 694
  • [6] Diffusion-weighted imaging and diffusion tensor imaging of the heart in vivo: major developments
    Mazur, Weronika
    Krzyzak, Artur T.
    Hennel, Franciszek
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2022, 18 (04): : 350 - 359
  • [7] DIFFUSION WEIGHTING BY THE TRACE OF THE DIFFUSION TENSOR WITHIN A SINGLE SCAN
    MORI, S
    VANZIJL, PCM
    MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (01) : 41 - 52
  • [8] Optimal preservation of porcine cardiac tissue prior to diffusion tensor magnetic resonance imaging
    Agger, Peter
    Lass, Thomas
    Smerup, Morten
    Frandsen, Jesper
    Pedersen, Michael
    JOURNAL OF ANATOMY, 2015, 227 (05) : 695 - 701
  • [9] In vivo diffusion tensor imaging of human calf muscle
    Sinha, U
    Yao, L
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (01) : 87 - 95
  • [10] In vivo diffusion tensor imaging of the human calf muscle
    Sinha, Shantanu
    Sinha, Usha
    Edgerton, V. Reggie
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (01) : 182 - 190