QTc interval on 24-hour holter monitor: To trust or not to trust?

被引:4
|
作者
Agha, Mhd Khalil Tamr [1 ]
Fakhri, Ghina [2 ]
Ahmed, Mohamed [3 ]
El Sedawy, Omar [2 ]
Saleh, Bernard Abi [4 ]
Bitar, Fadi [2 ]
Arabi, Mariam [2 ]
机构
[1] Childrens Mercy Kansas City, Div Pulm & Sleep Med, Dept Pediat, Kansas City, MO USA
[2] Amer Univ Beirut, Dept Pediat & Adolescent Med, Div Cardiol, Med Ctr, Beirut, Lebanon
[3] Amer Univ Beirut, Dept Family Med, Med Ctr, Beirut, Lebanon
[4] Amer Univ Beirut, Dept Internal Med, Div Cardiol, Med Ctr, Beirut, Lebanon
关键词
conduction disturbances; event recorder; holter; pediatric electrophysiology; QT dispersion; HEART-RATE; DIAGNOSTIC PERFORMANCE; CORRECTION FORMULAS; LONG; ELECTROCARDIOGRAPHY; DURATION;
D O I
10.1111/anec.12899
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction QT interval represents the ventricular depolarization and repolarization. Its accurate measurement is critical since prolonged QT can lead to sudden cardiac death. QT is affected by heart rate and is corrected to QTc via several formulae. QTc is commonly calculated on the ECG and not the 24-h Holter. Methods 100 patients presenting to our institution were evaluated by an ECG followed by a 24-h Holter. QTc measurement on both platforms using Bazett and Fridericia formulae was recorded and compared. Results Mean age was 14.09 years, with the majority being males. Mean heart rate was 125.87. In the ECG, the mean QTc interval via the Bazett formula was 0.40 s compared with 0.38 s using the Fridericia formula. The mean corrected QT via the Bazett formula was 0.45, 0.39, and 0.42 s for the shortest RR, the longest RR, and the average RR, respectively. In contrast to the Fridericia formula, the corrected QT interval was 0.40, 0.39, and 0.40 s for the shortest RR, the longest RR, and the average RR, respectively. Using the Bazett formula, the highest specificity was reached during the longest RR interval (92.2%), while the highest sensitivity was recorded during the shortest RR interval (40%). As for the Fridericiaformula, sensitivity always reached 0%, while the highest specificity was reached during the average RR interval. Conclusion QTc measured during Holter ECG reached a high specificity regardless of RR interval using the Fridericia and during the longest and the average RR interval for the Bazett formula. The consistently low sensitivity reveals that Holter ECG should not be used to rule out prolonged QT.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] QTc interval prolongation in HIV-infected patients: a case–control study by 24-hour Holter ECG recording
    Alessandra Fiorentini
    Nicola Petrosillo
    Angelo Di Stefano
    Stefania Cicalini
    Laura Borgognoni
    Evangelo Boumis
    Luigi Tubani
    Pierangelo Chinello
    [J]. BMC Cardiovascular Disorders, 12
  • [2] QTc period measured by a 24-hour Holter recording system in diabetic autosomic neuropathy
    Watzinger, N
    Schumacher, M
    Mostl, B
    Semlitsch, B
    Eber, B
    Fruhwald, F
    Zweiker, R
    Pokan, R
    Klein, W
    Pieber, T
    [J]. DIABETOLOGIA, 1996, 39 : 955 - 955
  • [3] QTc interval prolongation in HIV-infected patients: a case-control study by 24-hour Holter ECG recording
    Fiorentini, Alessandra
    Petrosillo, Nicola
    Di Stefano, Angelo
    Cicalini, Stefania
    Borgognoni, Laura
    Boumis, Evangelo
    Tubani, Luigi
    Chinello, Pierangelo
    [J]. BMC CARDIOVASCULAR DISORDERS, 2012, 12
  • [4] QTc interval is prolonged in nondipper hypertensive patients over the 24-hour period
    Passino, C
    Conforti, F
    Buralli, S
    Magagna, A
    Palombo, C
    Emdin, M
    [J]. CIRCULATION, 2000, 102 (18) : 431 - 431
  • [5] Cardiological evaluation of bicyclists by 24-hour holter
    Cruz-Campos, J. C.
    Cruz-Marquez, J. C.
    Cruz-Campos, A.
    Campos-Blasco, Ma T.
    Cueto-Martin, B.
    Garcia-Jimenez, Cl
    [J]. XXXI FIMS SPORTS MEDICINE WORLD CONGRESS, 2010, : 55 - 59
  • [6] Repolarization variability in 24-hour Holter ECG
    Burattini, L
    Bellagamba, G
    Balestrini, F
    Fratalocchi, N
    Pennacchietti, L
    De Bie, J
    [J]. COMPUTERS IN CARDIOLOGY 2000, VOL 27, 2000, 27 : 367 - 370
  • [7] CHARACTERISTICS OF VENTRICULAR ECTOPIC BEATS IN PATIENTS WITH VENTRICULAR TACHYCARDIA - 24-HOUR HOLTER MONITOR STUDY
    LICHSTEIN, E
    JONAS, S
    SUDBERG, L
    CHADDA, KD
    GUPTA, PK
    [J]. CHEST, 1978, 74 (03) : 342 - 342
  • [8] NEW ALGORITHM FOR QT INTERVAL-ANALYSIS IN 24-HOUR HOLTER ECG - PERFORMANCE AND APPLICATIONS
    LAGUNA, P
    THAKOR, NV
    CAMINAL, P
    JANE, R
    YOON, HR
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (01) : 67 - 73
  • [9] Evaluation of a 12-lead digital Holter system for 24-hour QT interval assessment
    Molnar, Janos
    Ranade, Vassant
    Cvetanovic, Ivana
    Molnar, Zita
    Somberg, John C.
    [J]. CARDIOLOGY, 2006, 106 (04) : 224 - 232
  • [10] CHARACTERISTICS OF VENTRICULAR ECTOPIC BEATS IN PATIENTS WITH VENTRICULAR-TACHYCARDIA - A 24-HOUR HOLTER MONITOR STUDY
    LICHSTEIN, E
    JONAS, S
    SMITH, H
    CHADDA, KD
    GUPTA, PK
    SUDBERG, L
    [J]. CHEST, 1980, 77 (06) : 731 - 735