Image Quality and Radiation Exposure With a Low Tube Voltage Protocol for Coronary CT Angiography Results of the PROTECTION II Trial

被引:190
|
作者
Hausleiter, Jorg
Martinoff, Stefan [1 ]
Hadamitzky, Martin
Martuscelli, Eugenio [2 ]
Pschierer, Iris [3 ]
Feuchtner, Gudrun M. [4 ]
Catalan-Sanz, Paz [5 ,6 ,7 ]
Czermak, Benedikt [8 ]
Meyer, Tanja S.
Hein, Franziska
Bischoff, Bernhard
Kuse, Miriam
Schomig, Albert
Achenbach, Stephan [9 ]
机构
[1] Tech Univ Munich, Inst Radiol & Nukl Med, Deutsch Herzzentrum Munchen Klin, Munich, Germany
[2] Univ Roma Tor Vergata, Dept Cardiol, Rome, Italy
[3] Krankenhaus Landshut Achdorf, Med Klin 1, Landshut, Germany
[4] Med Univ Innsbruck, Univ Klin Radiol 2, Innsbruck, Austria
[5] Ctr Med Asturias, Oviedo, Spain
[6] Hosp Santa Creu & Sant Pau, Barcelona, Spain
[7] Clin Creu Blanca, Barcelona, Spain
[8] Med Univ Innsbruck, Univ Klin Radiol 1, Innsbruck, Austria
[9] Univ Klinikum Erlangen, Med Klin 2, Erlangen, Germany
关键词
angiography; computed tomography; imaging; multislice; radiation dose; COMPUTED-TOMOGRAPHY; CARDIOLOGY; RADIOLOGY; COMMITTEE; IMPACT;
D O I
10.1016/j.jcmg.2010.08.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The purpose of this study was to evaluate image quality and radiation dose using a 100 kVp tube voltage scan protocol compared with standard 120 kVp for coronary computed tomography angiography (CTA) BACKGROUND Concerns have been raised about radiation exposure during coronary CTA The use of a 100 kVp tube voltage scan protocol effectively lowers coronary CTA radiation dose compared with standard 120 kVp, but it is unknown whether image quality is maintained METHODS We enrolled 400 nonobese patients who underwent coronary CTA 202 patients were randomly assigned to a 100 kVp protocol and 198 patients to a 120 kVp protocol The primary end point was to demonstrate noninferiority in image quality with the 100 kVp protocol which was assessed by a 4-point grading score (1 = nondiagnostic, 4 = excellent image quality) For the noninferiority analysis a margin of -02 image quality score points for the difference between both scan protocols was pre-defined Secondary end points included radiation dose and need for additional diagnostic tests during follow up RESULTS The mean image quality scores in patients scanned with 100 kVp and 120 kVp were 3 30 +/- 067 and 3 28 +/- 068, respectively (p = 0742), image quality of the 100 kVp protocol was not inferior as demonstrated by the 97 5% confidence interval of the difference, which did not cross the pre-defined noninferiority margin of -02 The 100 kVp protocol was associated with a 31% relative reduction in radiation exposure (dose-length product 868 +/- 317 mGy x cm with 120 kVp vs 599 +/- 255 mGy x cm with 100 kVp, p < 0 0001) At 30-day follow-up, the need for additional diagnostic studies did not differ (13 4% vs 19 2% for 100 kVp vs 120 kVp, respectively, p = 0 114) CONCLUSIONS A coronary CTA protocol using 100 kVp tube voltage maintained image quality, but reduced radiation exposure by 31% as compared with the standard 120 kVp protocol Thus, 100 kVp scan protocols should be considered for nonobese patients to keep radiation exposure as low as reasonably achievable (Prospective Randomized Trial on Radiation Dose Estimates of Cardiac CT Angiography in Patients Scanned With a 100 kVp Protocol [PROTECTION II], NCT00611780) (J Am Coll Cardiol Img 2010,3 1113-23) (C) 2010 by the American College of Cardiology Foundation
引用
下载
收藏
页码:1113 / 1123
页数:11
相关论文
共 50 条
  • [21] Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake
    Pan, Yue-ying
    Zhou, Shu-chang
    Wang, Yu-jin
    Li, Qian
    Zhu, Ting-ting
    Liu, Chun-xia
    Guan, Han-xiong
    CURRENT MEDICAL SCIENCE, 2020, 40 (01) : 178 - 183
  • [22] Imaging Quality Evaluation of Low Tube Voltage Coronary CT Angiography Using Low Concentration Contrast Medium
    Zhang, Chengzhong
    Yu, Yuejun
    Zhang, Zaixian
    Wang, Qingguo
    Zheng, Linfeng
    Feng, Yan
    Zhou, Zhiguo
    Zhang, Guixiang
    Li, Kangan
    PLOS ONE, 2015, 10 (03):
  • [23] Reduction in radiation exposure using a focused low-voltage scan before coronary CT angiography
    Al'Aref, Subhi J.
    Einstein, Andrew J.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2021, 15 (03) : 246 - 248
  • [24] Image quality and radiation dose of low tube voltage 3rd generation dual-source coronary CT angiography in obese patients: a phantom study
    Meinel, Felix G.
    Canstein, Christian
    Schoepf, U. Joseph
    Sedlmaier, Martin
    Schmidt, Bernhard
    Harris, Brett S.
    Flohr, Thomas G.
    De Cecco, Carlo N.
    EUROPEAN RADIOLOGY, 2014, 24 (07) : 1643 - 1650
  • [25] Application of 80-kVp tube voltage, low-concentration contrast agent and iterative reconstruction in coronary CT angiography: evaluation of image quality and radiation dose
    Wu, Qiyong
    Wang, Yong
    Kai, Huihua
    Wang, Tao
    Tang, Xiaoqiang
    Wang, Xiaoqin
    Pan, Changjie
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2016, 70 (9B) : B50 - B55
  • [26] Image quality and radiation dose of low tube voltage 3rd generation dual-source coronary CT angiography in obese patients: a phantom study
    Felix G. Meinel
    Christian Canstein
    U. Joseph Schoepf
    Martin Sedlmaier
    Bernhard Schmidt
    Brett S. Harris
    Thomas G. Flohr
    Carlo N. De Cecco
    European Radiology, 2014, 24 : 1643 - 1650
  • [27] Image quality of coronary CT angiography at ultra low tube voltage reconstructed with a deep-learning image reconstruction algorithm in patients of different weight
    Zhu, Lijuan
    Ha, Ruoshui
    Machida, Haruhiko
    Shi, Xiaomeng
    Wang, Fang
    Chen, Kemin
    Chen, Dazhi
    Cao, Yongpei
    Shen, Yun
    Yang, Lili
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (06) : 3891 - 3901
  • [28] Impact on image quality and radiation exposure in coronary CT angiography: 100 kVp versus 120 kVp
    Ripsweden, Jonaz
    Brismar, Torkel B.
    Holm, Jon
    Melinder, Annika
    Mir-Akbari, Habib
    Nilsson, Tage
    Nyman, Ulf
    Rasmussen, Elsbeth
    Ruck, Andreas
    Cederlund, Kerstin
    ACTA RADIOLOGICA, 2010, 51 (08) : 903 - 909
  • [29] Evaluate of the effect of low tube voltage on the radiation dosage using 640-slice coronary CT angiography
    Liu, Shihe
    Fu, Qing
    Yu, Hualong
    Zhang, Chuanyu
    Yang, Qing
    Hu, Yabin
    Xu, Wenjian
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (03) : 463 - 471
  • [30] CT Angiography of the Head-and-Neck Vessels Acquired with Low Tube Voltage, Low Iodine, and Iterative Image Reconstruction: Clinical Evaluation of Radiation Dose and Image Quality
    Zhang, Wei-lan
    Li, Min
    Zhang, Bo
    Geng, Hai-yang
    Liang, Yin-qiang
    Xu, Ke
    Li, Song-bai
    PLOS ONE, 2013, 8 (12):