Measurements of dose averaged LET distributions in lateral direction in water using CR-39 for collimated carbon ion beam

被引:0
|
作者
Kohno, R
Yasuda, N
Himukai, T
Kase, Y
机构
[1] Natl Inst Radiol Sci, Chiba 260, Japan
[2] Univ Tsukuba, Tsukuba, Ibaraki 305, Japan
[3] Tokyo Inst Technol, Meguro Ku, Tokyo 1528550, Japan
关键词
D O I
10.1118/1.1998452
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In order to develop more precise dose averaged LET calculation algorithm on the basis of the pencil beam algorithm (PBA) for carbon ion radiotherapy, we have to calculate depth and lateral dose averaged LET distribution for the pencil beam. Particularly, since the lateral dose averaged LET distribution is formed by scattered particles and fragment particles, we expected the distribution is somewhat complex. In this study, we focused on the lateral dose averaged LET distribution. Lateral dose averaged LET distributions were measured using CR‐39 LET detector and analyzed. Method and Materials: Carbon ion irradiation was carried out using the horizontal beam line at Heavy Ion Medical Accelerator in Chiba. A therapeutic carbon beam with energies of 290 MeV per nucleon (MeV/n) was used. Using a CR‐39 solid state track detector, lateral dose averaged LET distributions in water were measured at various depths for collimated mono‐energetic beam. Results: We analyzed etch pits on the CR‐39, and lateral dose averaged LET distributions in the region of penumbra were obtained. As a result, their LETs in even penumbra region were about constant at each depth. Conclusion: Lateral dose averaged LET distributions in water were measured at various depths for collimated mono‐energetic beam using a CR‐39 solid state track detector. It was obvious that their LETs in even penumbra region about constant at each depth. We found that lateral dose averaged LET can be calculated roughly using depth dose averaged LET for broad beam. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2109 / 2109
页数:1
相关论文
共 26 条
  • [1] Measurements of dose distributions in water using CR-39 for therapeutic carbon-ion beams
    Kohno, R
    Yasuda, N
    Himukai, T
    Ochiai, K
    Komori, M
    Matsufuji, N
    Kase, Y
    Kanematsu, N
    Kanai, T
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1798 - 1798
  • [2] Measurement of LET distributions by CR-39 for a carbon ion beam in the microporous structure
    Zhao, J.
    Yang, S.
    Chen, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1702 - S1704
  • [4] Measurements of dose-averaged linear energy transfer distributions in water using CR-39 plastic nuclear track detector for therapeutic carbon ion beams
    Kohno, R
    Yasuda, N
    Takeshi, H
    Kase, Y
    Ochiai, K
    Komori, M
    Matsufuji, N
    Kanai, T
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (12): : 8722 - 8726
  • [5] Measurements of linear energy transfer (LET) distributions by CR-39 for a therapeutic carbon ion beam with a new 2D ripple filter
    Yang, Shiyan
    Chen, Bo
    Zhuo, Weihai
    Shen, Hao
    Zhao, Jingfang
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2022, 197
  • [6] Secondary Neutron Dose Measurements Using CR-39 Detectors in Photon and Proton Radiotherapy
    Halg, R. A.
    Besserer, J.
    Mayer, S.
    Schneider, U.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [7] Measurement of therapeutic 12C beam in a water phantom using CR-39
    Yang, Shiyan
    Zhao, Jingfang
    Zhuo, Weihai
    Shen, Hao
    Chen, Bo
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2021, 41 (02) : 279 - 290
  • [8] Comparison of linear energy transfer measurement for therapeutic carbon beam using CR-39 and TLD
    Yuan, Zhou
    Zhuo, Weihai
    Yang, Shiyan
    Li, Zhiling
    Zhao, Jingfang
    Chen, Bo
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2024, 44 (02)
  • [9] Measurements of alpha radioactivity in arsenic contaminated tubewell drinking water using CR-39 detector
    Ghosh, D
    Deb, A
    Patra, KK
    [J]. RADIATION MEASUREMENTS, 2004, 38 (01) : 19 - 22
  • [10] Neutron dose estimation via LET spectrometry using CR-39 detector for the reaction Be-9 (p, n)
    Sahoo, G. S.
    Tripathy, S. P.
    Paul, S.
    Sharma, S. D.
    Sharma, S. C.
    Joshi, D. S.
    Bandyopadhyay, T.
    [J]. JOURNAL OF MEDICAL PHYSICS, 2014, 39 (04) : 225 - 230