Comparison of life cycle performance of distributed energy system and conventional energy system for district heating and cooling in China

被引:3
|
作者
Liu Chang-rong [1 ]
Tang Yi-fang [2 ]
Wang Han-qing [1 ,3 ]
Liu Zhi-qiang [1 ]
Yang Sheng [1 ]
Li Chao-jun [4 ]
Jin Wen-ting [4 ]
机构
[1] Cent South Univ, Sch Energy Sci & Engn, Changsha 410083, Peoples R China
[2] Hunan Univ Sci & Technol, Sch Civil Engn, Xiangtan 411201, Peoples R China
[3] Cent South Univ Forestry & Technol, Sch Civil Engn, Changsha 410004, Peoples R China
[4] Hunan Univ Technol, Sch Civil Engn, Zhuzhou 412007, Peoples R China
基金
中国国家自然科学基金;
关键词
life-cycle assessment; distributed energy system; conventional energy system; building cooling and heating; environmental impact; MULTIOBJECTIVE OPTIMIZATION; SOLAR COLLECTORS; PUMP; DESIGN;
D O I
10.1007/s11771-022-5073-y
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
The distributed energy system has achieved significant attention in respect of its application for single-building cooling and heating. Researching on the life cycle environmental impact of distributed energy systems (DES) is of great significance to encourage and guide the development of DES in China. However, the environmental performance of distributed energy systems in a building cooling and heating has not yet been carefully analyzed. In this study, based on the standards of ISO14040-2006 and ISO14044-2006, a life-cycle assessment (LCA) of a DES was conducted to quantify its environmental impact and a conventional energy system (CES) was used as the benchmark. GaBi 8 software was used for the LCA. And the Centre of Environmental Science (CML) method and Eco-indicator 99 (EI 99) method were used for environmental impact assessment of midpoint and endpoint levels respectively. The results indicated that the DES showed a better life-cycle performance in the usage phase compared to the CES. The life-cycle performance of the DES was better than that of the CES both at the midpoint and endpoint levels in view of the whole lifespan. It is because the CES to DES indicator ratios for acidification potential, eutrophication potential, and global warming potential are 1.5, 1.5, and 1.6, respectively at the midpoint level. And about the two types of impact indicators of ecosystem quality and human health at the endpoint level, the CES and DES ratios of the other indicators are greater than 1 excepting the carcinogenicity and ozone depletion indicators. The human health threat for the DES was mainly caused by energy consumption during the usage phase. A sensitivity analysis showed that the climate change and inhalable inorganic matter varied by 1.3% and 6.1% as the electricity increased by 10%. When the natural gas increased by 10%, the climate change and inhalable inorganic matter increased by 6.3% and 3.4%, respectively. The human health threat and environmental damage caused by the DES could be significantly reduced by the optimization of natural gas and electricity consumption.
引用
下载
收藏
页码:2357 / 2376
页数:20
相关论文
共 50 条
  • [21] Comparative environmental life cycle assessment of conventional energy storage system and innovative thermal energy storage system
    David B.R.
    Spencer S.
    Miller J.
    Almahmoud S.
    Jouhara H.
    International Journal of Thermofluids, 2021, 12
  • [22] Sustainable enhancement of district heating and cooling configurations by combining thermal energy storage and life cycle assessment
    Guillen-Lambea, Silvia
    Carvalho, Monica
    Delgado, Monica
    Lazaro, Ana
    CLEAN TECHNOLOGIES AND ENVIRONMENTAL POLICY, 2021, 23 (03) : 857 - 867
  • [23] Sustainable enhancement of district heating and cooling configurations by combining thermal energy storage and life cycle assessment
    Silvia Guillén-Lambea
    Monica Carvalho
    Monica Delgado
    Ana Lazaro
    Clean Technologies and Environmental Policy, 2021, 23 : 857 - 867
  • [24] Method for reducing energy consumption of pumps in multi source district heating and cooling system
    Nakano M.
    Fukumoto T.
    Komoda N.
    IEEJ Transactions on Electronics, Information and Systems, 2019, 139 (10) : 1175 - 1182
  • [25] Heating, cooling, and electrical load forecasting for a large-scale district energy system
    Powell, Kody M.
    Sriprasad, Akshay
    Cole, Wesley J.
    Edgar, Thomas F.
    ENERGY, 2014, 74 : 877 - 885
  • [26] Design optimization of a district heating and cooling system with a borehole seasonal thermal energy storage
    Fiorentini, Massimo
    Heer, Philipp
    Baldini, Luca
    ENERGY, 2023, 262
  • [27] Energy efficiency performance of multi-energy district heating and hot water supply system
    金楠
    赵靖
    朱能
    Journal of Central South University, 2012, 19 (05) : 1377 - 1382
  • [28] Energy efficiency performance of multi-energy district heating and hot water supply system
    Jin Nan
    Zhao Jing
    Zhu Neng
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2012, 19 (05) : 1377 - 1382
  • [29] Energy efficiency performance of multi-energy district heating and hot water supply system
    Nan Jin
    Jing Zhao
    Neng Zhu
    Journal of Central South University, 2012, 19 : 1377 - 1382
  • [30] Life cycle assessment of the district heating distribution system in China-network construction
    Li Zhen
    Wang Weiwei
    Sun Hongmin
    ADVANCES IN CIVIL ENGINEERING II, PTS 1-4, 2013, 256-259 : 2662 - 2666