Initial clinical experience with a powered circular stapler for colorectal anastomosis

被引:22
|
作者
Atallah, S. [1 ,2 ]
Kural, S. [3 ]
Banda, N. [1 ]
Banda, A. [1 ]
Bawaney, F. [1 ]
Cabral, F. [4 ]
Neychev, V [1 ,2 ]
Patel, C. [1 ,2 ]
Larach, S. [1 ,2 ]
机构
[1] Univ Cent Florida, Coll Med, Orlando, FL 32816 USA
[2] HCA North Florida Div, Winter Pk, FL 32792 USA
[3] Uludag Univ, Bursa, Turkey
[4] Inst Portugues Oncol Francisco Gentil, Lisbon, Portugal
关键词
Powered EEA; Echelon circular stapler; Colorectal anastomosis; Powered surgical stapler; 3D stapler; Intelligent surgical stapling; ERGONOMICS; SURGEONS; SIZE;
D O I
10.1007/s10151-020-02162-4
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background The Echelon circular (TM) powered stapler (ECP stapler) obviates the need for manual firing of conventional circular staplers during the construction of a colorectal anastomosis, but has not been evaluated clinically. The aim of this study was to perform a clinical evaluation of this stapler. Methods A retrospective review of the initial clinical experience of a single surgeon using the ECP stapler for left-sided colorectal anastomosis construction during elective colorectal resections for benign and malignant disease was conducted by analyzing results from a prospectively maintained study database. Additionally, four attending colorectal and/or general surgeons who had performed >= 5 colorectal operations with the ECP stapler were invited to complete an anonymous online survey to subjectively assess the user experience with the device. Statistical analysis was conducted using Microsoft Excel Version 15.33. Results Seventeen patients underwent left-sided anastomotic reconstruction using the ECP stapler. All donuts (proximal and distal) were intact. Anastomotic integrity was evaluated using the air-leak test utilizing flexible video sigmoidoscopy. No leaks were observed, although one patient (5.9%) developed a postoperative pelvic abscess. The anonymous survey was completed by all four surgeons. Subjective evaluation of the ECP stapler suggests that the overall stapling quality, overall device ease-of-use, and the overall perception of anastomotic quality as above average when compared to manual 'end-to-end anastomosis' (EEA) stapling devices. Conclusions In an initial clinical evaluation of the ECP stapler, the safety and ease-of-use of the device appears to be satisfactory. Powered stapling and the design of '3D stapling' may provide advantages over manual systems, and may improve the construction quality of left-sided colorectal anastomosis.
引用
收藏
页码:479 / 486
页数:8
相关论文
共 50 条
  • [41] Circular Stapler Method for Avoiding Stricture of Cervical Esophagogastric Anastomosis
    Osamu Shiraishi
    Takushi Yasuda
    Hiroaki Kato
    Kota Momose
    Yoko Hiraki
    Atsushi Yasuda
    Masayuki Shinkai
    Motohiro Imano
    Journal of Gastrointestinal Surgery, 2022, 26 : 725 - 732
  • [42] A DANGER OF END-TO SIDE MECHANICAL ANASTOMOSIS WITH A CIRCULAR STAPLER
    ADLOFF, M
    OLLIER, JC
    ARNAUD, JP
    PRESSE MEDICALE, 1983, 12 (21): : 1359 - 1361
  • [43] Improved anastomotic technique for esophagojejunal anastomosis using circular stapler
    Niihara, Masahiro
    Hiki, Naoki
    Hosoda, Kei
    Sakuraya, Mikiko
    Washio, Marie
    Chuman, Motohiro
    Yamashita, Keishi
    LANGENBECKS ARCHIVES OF SURGERY, 2022, 407 (01) : 353 - 356
  • [44] Anastomotic leak rate following the implementation of a powered circular stapler in elective colorectal surgeries: a retrospective cohort study
    Lie, Jessica J.
    Samarasinghe, Nadeesha
    Karimuddin, Ahmer A.
    Brown, Carl J.
    Phang, P. Terry
    Raval, Manoj J.
    Ghuman, Amandeep
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2024, 38 (10): : 5541 - 5546
  • [45] Anastomotic stricture with the EEA-Stapler after colorectal anastomosis
    Gomez, JM
    de la Cuesta, ER
    Guerra, GG
    Gallego, IV
    Garcia-Anguiano, F
    Romero, JMH
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 1997, 89 (11) : 839 - 842
  • [46] EXPERIENCE WITH THE USE OF THE CIRCULAR STAPLER IN RECTAL SURGERY
    KYZER, S
    GORDON, PH
    DISEASES OF THE COLON & RECTUM, 1992, 35 (07) : 696 - 706
  • [47] USE OF THE CIRCULAR STAPLER IN 1000 CONSECUTIVE COLORECTAL ANASTOMOSES - EXPERIENCE OF ONE SURGICAL-TEAM
    DETRY, RJ
    KARTHEUSER, A
    DELRIVIERE, L
    SABA, J
    KESTENS, PJ
    SURGERY, 1995, 117 (02) : 140 - 145
  • [48] TREATMENT OF A STENOTIC COLORECTAL ANASTOMOSIS BY TRANSANAL USE OF AN ENDOSCOPIC STAPLER
    LAUSTEN, SB
    SAKSO, P
    BRITISH JOURNAL OF SURGERY, 1994, 81 (01) : 144 - 144
  • [49] Clinical results of circular stapler hemorrhoidectomy
    Kang, J.
    Ahn, Y.
    Kim, K.
    Song, J.
    Choi, Y.
    ISUCRS: PROCEEDINGS OF THE XXI BIENNIAL CONGRESS OF THE INTERNATIONAL SOCIETY OF UNIVERSITY COLON AND RECTAL SURGEONS, 2006, : 99 - 102
  • [50] Rectal stenosis after circular mechanical anastomosis; the influence of stapler size
    Llorach-Perucho, Nuria
    Cayetano-Paniagua, Ladislao
    Esteve-Monja, Pau
    Garcia-Nalda, Albert
    Bargallo, Josep
    Serra-Aracil, Xavier
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2024, 38 (12): : 7261 - 7268