Application of exergy method to a two-stage irreversible combined refrigeration system

被引:2
|
作者
Su, Y-F
Chen, C-K [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Mech Engn, Tainan 70101, Taiwan
[2] Far E Univ, Dept Automat & Control Engn, Tainan, Taiwan
关键词
exergy; optimization; irreversible; combined; refrigeration;
D O I
10.1243/0954406JMES459
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The exergy method, based on the maximum exergetic efficiency criterion, is applied to a two-stage irreversible combined refrigeration system. The exergetic efficiency defined as the ratio of rate of exergy output to rate of exergy input is taken as the objective index to be maximized. The related cycle temperature parameters are first solved. The maximum exergetic efficiency is then obtained analytically. Comparisons between the exergetic efficiency and the coefficient of performance of the combined refrigeration system are performed. The influences of various parameters on the system performances are discussed. It shows that the exergy method is practical and effective when operating or designing the combined refrigeration system.
引用
收藏
页码:807 / 813
页数:7
相关论文
共 50 条
  • [21] Interaction analysis of a two-stage refrigeration control system
    Asmar, BN
    Wilson, JA
    Jones, WE
    [J]. 1997 JUBILEE RESEARCH EVENT, VOLS 1 AND 2, 1997, : 741 - 744
  • [22] Optimization of Intermediate Pressure of the Two-stage Refrigeration System
    Hoang, M. T.
    Vo, C. C.
    Nguyen, T. V.
    Vu, H. K.
    [J]. PROCEEDINGS OF 2018 4TH INTERNATIONAL CONFERENCE ON GREEN TECHNOLOGY AND SUSTAINABLE DEVELOPMENT (GTSD), 2018, : 370 - 373
  • [23] Optimal performance characteristics of a two-stage irreversible combined refrigeration system under maximum cooling load per unit total cost conditions
    Sahin, B
    Kodal, A
    Koyun, A
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2001, 42 (04) : 451 - 465
  • [24] Design of two-stage quick chilling refrigeration system for pig processing in an engineering application
    Xue, Lianzheng
    Zhang, Junrong
    [J]. JOURNAL OF FOOD PROCESS ENGINEERING, 2021, 44 (06)
  • [25] Performance analysis and parametric optimization of a two-stage irreversible magnetic Brayton refrigeration cycle
    Zhang, Xiu-Qin
    Lin, Guo-Xing
    Chen, Jin-Can
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2009, 30 (10): : 1635 - 1638
  • [26] Exergy and Cost Optimization of a Two-Stage Refrigeration System Using Refrigerant R32 and R410A
    Roy, Ranendra
    Bhowal, Arup Jyoti
    Mandel, Bijan Kumar
    [J]. JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2020, 12 (03)
  • [27] COMPARISON OF DIFFERENT REFRIGERANTS FOR A TWO-STAGE TRANSPORT REFRIGERATION SYSTEM
    Moehlenkamp, A.
    Lemke, N.
    Koehler, J.
    [J]. 3RD IIR INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN, 2014, 2014 (01): : 676 - 686
  • [28] Comprehensive performance analysis of cascade refrigeration system with two-stage compression for industrial refrigeration
    Sun, Zhili
    Wang, Yi 'an
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2022, 39
  • [29] Comprehensive performance analysis of cascade refrigeration system with two-stage compression for industrial refrigeration
    Sun, Zhili
    Wang, Yi'An
    [J]. Case Studies in Thermal Engineering, 2022, 39
  • [30] Evaluation of the ejector two-stage compression refrigeration cycle with work performance from energy, conventional exergy and advanced exergy perspectives
    Yang, Dazhang
    Jie, Zhu
    Zhang, Qing
    Li, Yang
    Xie, Jing
    [J]. ENERGY REPORTS, 2022, 8 : 12944 - 12957