摘要
Purpose-Coronary artery stenosis, or abnormal narrowing, is a widespread and potentially fatal cardiac disease. After treatment by balloon angioplasty and stenting, restenosis may occur inside the stent due to excessive neointima formation. Simulations of in-stent restenosis can provide new insight into this process. However, uncertainties due to variability in patient-specific parameters must be taken into account. Methods-We performed an uncertainty quantification (UQ) study on a complex two-dimensional in-stent restenosis model. We used a quasi-Monte Carlo method for UQ of the neointimal area, and the Sobol sensitivity analysis (SA) to estimate the proportions of aleatory and epistemic uncertainties and to determine the most important input parameters. Results-We observe approximately 30% uncertainty in the mean neointimal area as simulated by the model. Depending on whether a fast initial endothelium recovery occurs, the proportion of the model variance due to natural variability ranges from 15 to 35%. The endothelium regeneration time is identified as the most influential model parameter. Conclusion-The model output contains a moderate quantity of uncertainty, and the model precision can be increased by obtaining a more certain value on the endothelium regeneration time. We conclude that the quasi-Monte Carlo UQ and the Sobol SA are reliable methods for estimating uncertainties in the response of complicated multiscale cardiovascular models.
引用
收藏
页码:761 / 774
页数:14
相关论文
共 50 条
  • [1] Uncertainty Quantification of a Multiscale Model for In-Stent Restenosis
    Anna Nikishova
    Lourens Veen
    Pavel Zun
    Alfons G. Hoekstra
    [J]. Cardiovascular Engineering and Technology, 2018, 9 : 761 - 774
  • [2] Semi-intrusive multiscale metamodelling uncertainty quantification with application to a model of in-stent restenosis
    Nikishova, A.
    Veen, L.
    Zun, P.
    Hoekstra, A. G.
    [J]. PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2019, 377 (2142):
  • [3] Non-intrusive and semi-intrusive uncertainty quantification of a multiscale in-stent restenosis model
    Ye, Dongwei
    Nikishova, Anna
    Veen, Lourens
    Zun, Pavel
    Hoekstra, Alfons G.
    [J]. RELIABILITY ENGINEERING & SYSTEM SAFETY, 2021, 214
  • [4] Uncertainty quantification of a three-dimensional in-stent restenosis model with surrogate modelling
    Ye, Dongwei
    Zun, Pavel
    Krzhizhanovskaya, Valeria
    Hoekstra, Alfons G.
    [J]. JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2022, 19 (187)
  • [5] Towards a Complex Automata Multiscale Model of In-Stent Restenosis
    Caiazzo, Alfonso
    Evans, David
    Falcone, Jean-Lue
    Hegewald, Jan
    Lorenz, Eric
    Stahl, Bernd
    Wang, Dinan
    Bernsdorf, Joerg
    Chopard, Bastien
    Gunn, Julian
    Hose, Rod
    Krafczyk, Manfred
    Lawford, Patricia
    Smallwood, Rod
    Walker, Dawn
    Hoekstra, Alfons G.
    [J]. COMPUTATIONAL SCIENCE - ICCS 2009, PART I, 2009, 5544 : 705 - 714
  • [6] In-Stent Restenosis
    Kim, Michael S.
    Dean, Larry S.
    [J]. CARDIOVASCULAR THERAPEUTICS, 2011, 29 (03) : 190 - 198
  • [7] A novel mouse model of in-stent restenosis
    Rodriguez-Menocal, Luis
    Wei, Yuntao
    Pham, Si M.
    St-Pierre, Melissa
    Li, Sen
    Webster, Keith
    Goldschmidt-Clermont, Pascal
    Vazquez-Padron, Roberto I.
    [J]. ATHEROSCLEROSIS, 2010, 209 (02) : 359 - 366
  • [8] In-stent restenosis
    Saeed, G
    Bass, T
    [J]. CORONARY ARTERY DISEASE: PREVENTION TO INTERVENTION, 2000, : 115 - 122
  • [9] Effect of stent on radiation dosimetry in an in-stent restenosis model
    Ravi, K
    Sherman, W
    Fox, J
    Reimers, C
    Fan, P
    Chiu-Tsao, S
    Harrison, L
    [J]. EUROPEAN HEART JOURNAL, 2000, 21 : 400 - 400
  • [10] EVALUATION OF A DIABETIC RABBIT MODEL FOR IN-STENT RESTENOSIS
    Radke, P. W.
    Joost, A.
    Kaiser, A.
    Basler, M.
    Mandapathil, M.
    Weber, C.
    Yla-Herttuala, S.
    Ito, W.
    [J]. ATHEROSCLEROSIS SUPPLEMENTS, 2011, 12 (01) : 86 - 86