Elemental analysis of hair using PIXE-tomography and INAA

被引:18
|
作者
Beasley, D. [1 ]
Gomez-Morilla, I. [1 ]
Spyrou, N. [1 ]
机构
[1] Univ Surrey, Sch Elect & Phys Sci, Ctr Nucl & Radiat Phys, Dept Phys, Guildford GU2 7XH, Surrey, England
关键词
D O I
10.1007/s10967-007-0416-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
3D quantitative elemental maps of a section of a strand of hair were produced using a combination of PIXE-Tomography and simultaneous On/Off Axis STIM-Tomography at the University of Surrey Ion Beam Centre. The distributions of S, K, Cl, Ca, Fe and Zn were determined using the PIXE-T reconstruction package DISRA. The results were compared with conventional bulk PIXE analysis of tomographic data as determined using Dan32. The overall concentrations determined by PIXE were compared with elemental concentrations held in the University of Surrey Hair Database. All the entries currently in the database were produced using INAA. The merits and possible contributions of tomographic ME analysis to analysis of hair are discussed. The conclusions drawn from the ME-Tomography analysis can be used to argue for more stringent procedures for hair analysis at the University of Surrey.
引用
收藏
页码:101 / 105
页数:5
相关论文
共 50 条
  • [21] Elemental Analysis of Glass and Bakelite Electrodes Using PIXE Facility
    Manisha
    Bhatnagar, V
    Shahi, J. S.
    Verma, S.
    Mohanty, B. P.
    Kumar, A.
    XXII DAE HIGH ENERGY PHYSICS SYMPOSIUM, 2018, 203 : 583 - 586
  • [22] Elemental investigation of Syrian medicinal plants using PIXE analysis
    Rihawy, M. S.
    Bakraji, E. H.
    Aref, S.
    Shaban, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (17-18): : 2790 - 2793
  • [23] Elemental analysis of glass and bakelite electrodes using PIXE facility
    Manisha
    Bhatnagar, V.
    Shahi, J.S.
    Verma, S.
    Mohanty, B.P.
    Kumar, A.
    arXiv, 2017,
  • [24] PIXE - A NOVEL TECHNIQUE FOR ELEMENTAL ANALYSIS
    JOHANSSON, SAE
    ENDEAVOUR, 1989, 13 (02) : 48 - 53
  • [25] PIXE and Its Applications to Elemental Analysis
    Ishii, Keizo
    QUANTUM BEAM SCIENCE, 2019, 3 (02)
  • [26] The University of Surrey's new proton microprobe and the feasibility of PIXE-tomography for trace element analysis of biological tissues
    N. M. Spyrou
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 264 : 289 - 294
  • [27] ELEMENTAL ANALYSIS OF CATARACTOUS LENSES BY PIXE
    KOYAMAITO, H
    JAHNKE, A
    WADA, E
    TSUMITA, T
    YAMAZAKI, T
    NUCLEAR INSTRUMENTS & METHODS, 1979, 166 (02): : 269 - 276
  • [28] ELEMENTAL ANALYSIS OF ALGAE WITH PIXE AND PIGME
    MACARTHUR, JD
    PALMER, GR
    HEKMAN, WE
    BUDD, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 218 (1-3): : 519 - 524
  • [29] Inaa and pixe analysis of Caborn-Welborn ceramics.
    Shergur, J
    Robertson, JD
    Pollack, D
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 218 : U1052 - U1052
  • [30] Quantitative elemental analysis of rat bone using micro-PIXE analysis
    Kato, Yugo
    Yakumaru, Haruko
    Ayama, Kyoko
    Oikawa, Masakazu
    Homma-Takeda, Shino
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2024, 555