Evaluation of COBAS AMPLICOR (Roche):: Accuracy in detection of Chlamydia trachomatis and Neisseria gonorrhoeae by coamplification of endocervical specimens

被引:26
|
作者
Livengood, CH [1 ]
Wrenn, JW [1 ]
机构
[1] Duke Univ, Med Ctr, Chlamydia Lab, Durham, NC USA
关键词
D O I
10.1128/JCM.39.8.2928-2932.2001
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
We evaluated further the accuracy of the COBAS AMPLICOR (Roche) (CA) PCR-based system in detection of Chlamydia trachomatis and Neisseria gonorrhoeae in endocervical specimens. Endocervical specimens collected for any indication for testing for C. trachomatis and N. gonorrhoeae among a university hospital health system population were included. Testing for C. trachomatis was done by two PCR methods, CA and manual microwell AMPLICOR (Roche) (MWA), and by culture; testing for N. gonorrhoeae was done by CA and culture. Discrepancy resolution was performed. Reproducibility testing and hands-on labor time measurements for CA were done. Among 654 C. trachomatis samples, the prevalence of true positivity was 9.2%, and among the 618 N. gonorrhoeae samples, the prevalence of true positivity was 4.4%. For detection of C. trachomatis, the sensitivity, specificity, and negative and positive predictive values were, respectively, as follows for each test: CA, 93.3, 99.7, 99.3, and 96.4%; MWA, 91.7, 99.7, 99.2, and 96.5%; and culture, 65.0, 100, 96.6, and 100%. For detection of N. gonorrhoeae those values were as follows: CA, 96.3, 100, 99.8, and 100%; and culture, 92.6, 100, 99.7, and 100%. Hands-on labor time for each clinical result was estimated to be at 7.5 min. The prevalence of inhibitory specimens was 3.5%, including two positive C. trachomatis samples which would have been missed otherwise. The direct cost of each clinical result with CA was estimated to be $9.09. Our methods include a diverse range of indications for testing among women, using endocervical swabbing samples, 2 M sucrose phosphate transport medium, and discrepancy resolution for comparison. Under our test conditions, the CA system is an accurate, rapid, and cost- and labor-efficient method for detection of C. trachomatis and N. gonorrhoeae.
引用
收藏
页码:2928 / 2932
页数:5
相关论文
共 50 条
  • [1] EVALUATION OF THE ROCHE COBAS 4800 FOR THE DETECTION OF CHLAMYDIA TRACHOMATIS AND NEISSERIA GONORRHOEAE USING ENDOCERVICAL SPECIMENS
    Pantone, A.
    Van der Pol, B.
    Lillis, R.
    Loyd, B.
    Nye, M. B.
    Taylor, S.
    [J]. SEXUALLY TRANSMITTED INFECTIONS, 2011, 87 : A278 - A279
  • [2] Evaluation of magnapure extractions for screening of Chlamydia trachomatis and Neisseria gonorrhoeae in the Roche COBAS amplicor assay
    Montalvan, I.
    Shah, M.
    Lam, X.
    Millard, C.
    Hutchinson, A.
    Fernandes, H.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2006, 8 (05): : 668 - 668
  • [3] High frequency of competitive inhibition in the Roche Cobas AMPLICOR multiplex PCR for Chlamydia trachomatis and Neisseria gonorrhoeae
    Hamilton, MS
    Otto, M
    Nickell, A
    Abel, D
    Ballam, Y
    Schremmer, R
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (11) : 4393 - 4393
  • [4] Evaluation of the Roche cobas® CT/NG Test for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Male Urine
    Taylor, Stephanie N.
    Liesenfeld, Oliver
    Lillis, Rebecca A.
    Body, Barbara A.
    Nye, Melinda
    Williams, James
    Eisenhut, Carol
    Hook, Edward W., III
    Van der Pol, Barbara
    [J]. SEXUALLY TRANSMITTED DISEASES, 2012, 39 (07) : 543 - 549
  • [5] EVALUATION OF THE ROCHE COBAS 4800 FOR THE DETECTION OF CHLAMYDIA TRACHOMATIS AND NEISSERIA GONORRHOEAE USING MINIMALLY INVASIVE SAMPLES IN WOMEN
    Hires, L.
    Van der Pol, B.
    Taylor, S.
    Lillis, R.
    Body, B.
    [J]. SEXUALLY TRANSMITTED INFECTIONS, 2011, 87 : A278 - A278
  • [6] Reproducibility of the Roche Amplicor polymerase chain reaction assay for detection of infection by Chlamydia trachomatis in endocervical specimens
    Mulcahy, GM
    Albanese, EA
    Bachl, BL
    [J]. CLINICAL CHEMISTRY, 1998, 44 (07) : 1575 - 1578
  • [7] Evaluation of the aptima combo 2 assay for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in specimens previously tested on the Roche amplicor polymerase chain reaction assay
    Mihalov, Michael
    Ali, Estrellita
    Baltadjieva, Boyka
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2006, 126 (04) : 651 - 651
  • [8] Evaluation of an automated extraction method for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae by Cobas Amplicor PCR from different sample materials
    Geertsen, Ralf
    Friderich, Paul
    Dobec, Marinko
    Emler, Stefan
    [J]. SCANDINAVIAN JOURNAL OF INFECTIOUS DISEASES, 2007, 39 (05) : 405 - 408
  • [9] Detection of Neisseria gonorrhoeae and Chlamydia trachomatis in genitourinary specimens from men and women by a coamplification PCR assay
    Crotchfelt, KA
    Welsh, LE
    DeBonville, D
    Rosenstraus, M
    Quinn, TC
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (06) : 1536 - 1540
  • [10] Detection of male genital infection with Chlamydia trachomatis and Neisseria gonorrhoeae using an automated multiplex PCR system (Cobas® Amplicor™)
    Higgins, SP
    Klapper, PE
    Struthers, JK
    Bailey, AS
    Gough, AP
    Moore, R
    Corbitt, G
    Bhattacharyya, MN
    [J]. INTERNATIONAL JOURNAL OF STD & AIDS, 1998, 9 (01) : 21 - 24