Optical coherence computed tomography - art. no. 68550H

被引:0
|
作者
Li, Li [1 ]
Wang, Lihong V. [1 ]
机构
[1] Washington Univ, Dept Biomed Engn, Opt Imaging Lab, St Louis, MO 63117 USA
关键词
optical coherence tomography; diffuse optical tomography; Monte Carlo; radiative transfer;
D O I
10.1117/12.761431
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We proposed a novel time-resolved optical tomography, optical coherence computed tomography. It married the key concepts of time-resolved diffuse optical tomography and optical coherence tomography. Both ballistic and multiple-scattered photons were measured at multiple source-detection positions by low-coherence interferometry. It measures the reemitted light with a temporal resolution of 56 femtoseconds, which is much better than the resolution of conventional time-resolved detection systems. A light-tissue interaction model was established using the time-resolved Monte Carlo method. The optical properties were then reconstructed by solving the inverse time-resolved radiative transport problem under the first Born approximation. Our initial results showed the potential of this technology to bridge the gap between diffuse optical tomography and optical coherence tomography.
引用
收藏
页码:H8550 / H8550
页数:8
相关论文
共 50 条
  • [41] Endoscopic spectral-domain polarization-sensitive optical coherence tomography system - art. no. 66211K
    Wang Yi
    Chen Xiaodong
    Hu Zhiqiang
    Li Qiao
    Yu Daoyin
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2007: PHOTOELECTRONIC IMAGING AND DETECTION, 2008, 6621 : K6211 - K6211
  • [42] Polarization vortices in optical design - art. no. 66670H
    Brown, Thomas G.
    CURRENT DEVELOPMENTS IN LENS DESIGN AND OPTICAL ENGINEERING VIII, 2007, 6667 : H6670 - H6670
  • [43] Quantum zeno tomography -: art. no. 012110
    Facchi, P
    Hradil, Z
    Krenn, G
    Pascazio, S
    Rehácek, J
    PHYSICAL REVIEW A, 2002, 66 (01): : 121101 - 121108
  • [44] Minimal qubit tomography -: art. no. 052321
    Rehácek, J
    Englert, BG
    Kaszlikowski, D
    PHYSICAL REVIEW A, 2004, 70 (05): : 052321 - 1
  • [45] Optical coherence tomography:: State of the art
    Knüttel, A
    Bonev, S
    Höpfner, A
    Kugler, C
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 102 - 105
  • [46] Replication of precise optical waveguide for an optical device - art. no. 61241H
    Jeong, Myung Yung
    Optoelectronic Integrated Circuits VIII, 2006, 6124 : H1241 - H1241
  • [47] Large area full-field optical coherence tomography using white light source - art. no. 67961F
    Chang, Shoude
    Mao, Youxin
    Sherif, Sherif
    Flueraru, Costel
    PHOTONICS NORTH 2007, PTS 1 AND 2, 2007, 6796 : F7961 - F7961
  • [48] Evaluation of the reconstruction algorithms for a phase-stepped full-field Optical Coherence Tomography - art. no. 60260O
    Qu, JL
    Ding, ZH
    Xu, GX
    Lin, ZY
    Niu, HB
    ICO20: Biomedical Optics, 2006, 6026 : O260 - O260
  • [49] Speckle reduction method for optical coherence tomography using interval type II fuzzy set - art. no. 68472B
    Puvanathasan, Prabakar
    Bizheva, Kostadinka
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE XII, 2008, 6847 : B8472 - B8472
  • [50] Investigation of photoacoustic guidance of diffusive optical tomography - art. no. 68560V
    Gamelin, John
    Maurudis, Anastasios
    Aguirre, Andres
    Zhu, Quing
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2008: THE NINTH CONFERENCE ON BIOMEDICAL THERMOACOUSTICS, OPTOACOUSTICS, AND ACOUSTIC-OPTICS, 2008, 6856 : V8560 - V8560