Validation of High-Resolution peripheral Quantitative Computed Tomography-Derived Achilles Tendon Properties Against Diagnostic Ultrasound

被引:0
|
作者
Fung, Hugo J. W. [1 ,2 ]
Cheung, Angela M. [2 ,3 ,4 ,5 ]
Mathur, Sunita [6 ,7 ]
Szabo, Eva [2 ,5 ]
Wong, Andy K. O. [2 ,4 ,5 ,7 ,8 ]
机构
[1] Univ Toronto, Fac Kinesiol & Phys Educ, Dept Exercise Sci, Toronto, ON, Canada
[2] Univ Toronto, Ctr Excellence Skeletal Hlth Assessment, Toronto, ON, Canada
[3] Univ Hlth Network, Dept Med, Toronto, ON, Canada
[4] Univ Hlth Network, Toronto Gen Hosp Res Inst, Toronto, ON, Canada
[5] Univ Hlth Network, Schroeders Arthrit Inst, Osteoporosis Program, Toronto, ON, Canada
[6] Univ Toronto, Fac Med, Dept Phys Therapy, Toronto, ON, Canada
[7] Univ Toronto, Fac Med, Rehabil Sci Inst, Toronto, ON, Canada
[8] Univ Toronto, Dalla Lana Sch Publ Hlth, Dept Epidemiol, Toronto, ON, Canada
关键词
Achilles Tendon; HR-pQCT; Tendon Cross-Sectional Area; Tendon Density; Ultrasound; IN-VIVO ASSESSMENT; BONE MICROARCHITECTURE; DISTAL RADIUS; STRENGTH; MUSCLE; REPRODUCIBILITY; TENDINOPATHY; EXPRESSION; PRECISION; EXERCISE;
D O I
暂无
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Objectives: 1) To assess the precision of high resolution peripheral quantitative computed tomography (HR-pQCT)derived Achilles tendon (AT) cross-sectional area (HR AT-CSA) and density, and 2) to validate HR AT-CSA against ultrasound-derived AT-CSA (US AT-CSA). Methods: Women and men (>= 50 years) had HR-pQCT (0.082mm isotropic) and US scans (B-mode) performed on the non-dominant ankle. Linear regression and Bland-Altman analyses assessed systematic differences between HR-pQCT and US-derived AT-CSA. Precision measured by % root mean square coefficients of variation (%RMSCV) and agreement by type 2,1 intraclass correlation coefficients (ICC2,1), were determined for testretest US AT-CSA scans, and analysis-reanalysis of 30 HR-pQCT and US images. Results: Among 44 participants, HR and US AT-CSA were strongly correlated (R2=0.84, p<0.01, B=1.05[0.90-1.19]), with no differences between modalities (p=0.37). Bland-Altman analysis revealed minimal systematic bias (-0.7mm2[-10.7-9.3]; 1.3%) between HR-pQCT and US-derived AT-CSA with smaller AT-CSA values showing larger inter-modality differences (R2=0.098, B=-0.137 [-0.268--0.008], p=0.039). US AT-CSA demonstrated excellent test-retest precision (ICC2,1=0.998, %RMSCV=1.04%). Analysis-reanalysis of HR-pQCT AT-density and both HR-pQCT and US AT-CSA displayed ICC2,1 above 0.95 and %RMSCV within 3%. Conclusion: HR-pQCT can examine AT-morphometry with acceptable analytical precision. Future studies should explore these metrics' association with functional outcomes and ankle-bone structural and mechanical properties.
引用
收藏
页码:203 / 211
页数:9
相关论文
共 50 条
  • [41] Guidelines for the assessment of bone density and microarchitecture in vivo using high-resolution peripheral quantitative computed tomography
    D.E. Whittier
    S.K. Boyd
    A.J. Burghardt
    J. Paccou
    A. Ghasem-Zadeh
    R. Chapurlat
    K. Engelke
    M.L. Bouxsein
    Osteoporosis International, 2020, 31 : 1607 - 1627
  • [42] Human Bone Loss Assessed by High-Resolution Peripheral Quantitative Computed Tomography and Ultrasonic Transmission Techniques
    Dongsheng Bi
    Chengcheng Liu
    Zhongquan Dai
    Zhili Li
    Ying Li
    Boyi Li
    Dan Li
    Linjie Wang
    Lina Qu
    Yinghui Li
    Dean Ta
    Microgravity Science and Technology, 35
  • [43] Consequences of Hyperthyroidism and Its Treatment for Bone Microarchitecture Assessed by High-Resolution Peripheral Quantitative Computed Tomography
    Nicolaisen, Pia
    Obling, Maria Lohman
    Winther, Kristian Hillert
    Hansen, Stinus
    Hermann, Anne Pernille
    Hegedus, Laszlo
    Bonnema, Steen Joop
    Brix, Thomas Heiberg
    THYROID, 2021, 31 (02) : 208 - 216
  • [44] Guidelines for the assessment of bone density and microarchitecture in vivo using high-resolution peripheral quantitative computed tomography
    Whittier, D. E.
    Boyd, S. K.
    Burghardt, A. J.
    Paccou, J.
    Ghasem-Zadeh, A.
    Chapurlat, R.
    Engelke, K.
    Bouxsein, M. L.
    OSTEOPOROSIS INTERNATIONAL, 2020, 31 (09) : 1607 - 1627
  • [45] Bone microstructure and volumetric density in hemodialysis patients: assessed by high-resolution peripheral quantitative computed tomography
    Cejka, Daniel
    Patsch, Janina
    Weber, Michael
    Diarra, Danielle
    Riegersperger, Markus
    Kikic, Zeljko
    Krestan, Christian
    Schueller-Weidekamm, Claudia
    Kainberger, Franz
    Haas, Martin
    WIENER KLINISCHE WOCHENSCHRIFT, 2010, 122 (17-18) : A32 - A33
  • [46] Repair of Bone Erosion in Rheumatoid Arthritis by Denosumab: A High-Resolution Peripheral Quantitative Computed Tomography Study
    Yue, Jiang
    Griffith, James F.
    Xiao, Fan
    Shi, Lin
    Wang, Defeng
    Shen, Jiayun
    Wong, Priscilla
    Li, Edmund K.
    Li, Martin
    Li, Tena K.
    Zhu, Tracy Y.
    Hung, Vivian W.
    Qin, Ling
    Tam, Lai-Shan
    ARTHRITIS CARE & RESEARCH, 2017, 69 (08) : 1156 - 1163
  • [47] Diagnostic Efficacy of High-Resolution Computed Tomography Densitometry for Diagnosing Otosclerosis
    Puiggros, Ignacio Viza
    Moreno, Esther Granell
    Dotu, Cesar Orus
    Agusti, Miquel Quer i
    Diaz, Francesc Larrosa
    OTOLOGY & NEUROTOLOGY, 2023, 44 (10) : E697 - E701
  • [48] Quantitative High-Resolution Computed Tomography Predicts Progressive Pulmonary Fibrosis
    Koslow, M.
    Baraghoshi, D.
    Strand, M.
    Solomon, J.
    Swigris, J. J.
    Lynch, D. A.
    Mohning, M. P.
    Yunt, Z. X.
    Keith, R.
    Perez, E. Fernandez
    Huie, T. J.
    Brown, K. K.
    Humphries, S. M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207
  • [49] In vivo assessment of the micro-structural properties of bone using high-resolution peripheral quantitative computed tomography (Hr-pQCT)
    Paggiosi, M. A.
    BONE, 2012, 50 : S16 - S16
  • [50] Bone Structure and Estimated Bone Strength in Obese Patients Evaluated by High-Resolution Peripheral Quantitative Computed Tomography
    Stine Andersen
    Katrine Diemer Frederiksen
    Stinus Hansen
    Kim Brixen
    Jeppe Gram
    René Klinkby Støving
    Calcified Tissue International, 2014, 95 : 19 - 28