Quantitative analysis of heavy metals in soil by X-ray fluorescence with PCA-ANOVA and support vector regression

被引:0
|
作者
Yang, Wanqi [1 ,2 ]
Li, Fusheng [1 ,2 ]
Zhao, Yanchun [1 ,2 ]
Lu, Xin [1 ,2 ]
Yang, Siyuan [1 ,2 ]
Zhu, Pengfei [1 ,2 ]
机构
[1] Univ Elect Sci & Technol China, Sch Automat Engn, Chengdu 611731, Sichuan, Peoples R China
[2] Univ Elect Sci & Technol China, Yangtze Delta Reg Inst Huzhou, Huzhou 313001, Peoples R China
基金
中国国家自然科学基金;
关键词
PLASMA-MASS SPECTROMETRY; MULTIVARIATE CALIBRATION; MULTIELEMENTAL ANALYSIS; ICP-OES; POLLUTION;
D O I
10.1039/d2ay00593j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Heavy metal concentration is an important index for evaluating soil pollution. It is of great significance to measure the trace element content accurately for green agriculture development. In order to detect the trace element content accurately, a new prediction framework including pre-processing, signal extraction, feature selection and decision-making was proposed. The energy dispersive X-ray fluorescence (ED-XRF) spectra of 57 national standard soil samples were investigated based on the proposed methods. Firstly, an innovative background deduction method called iterative adaptive window empirical wavelet transform (IAWEWT) was introduced to extract effective counts of characteristic peaks, and the proposed approach was validated by the coefficient of determination (R-2) of the instrumental calibration curve compared with two other conventional methods. Secondly, principal component analysis (PCA) was combined with the analysis of variance (ANOVA) for variable selection optimization of the ED-XRF spectrum. After PCA feature extraction and ANOVA variable selection treatment, the optimum number of principal components for V, Cr, Cu, Zn, Mo, Cd and Pb were determined to be 7, 15, 4, 4, 4, 5 and 12 respectively. Furthermore, the support vector regression (SVR) model was adopted for heavy metal estimation. The evaluation indices included R-2 and root mean square error (RMSE). It was demonstrated that the predictive capabilities of seven heavy metal elements were improved substantially for elemental analysis by the proposed PCA-ANOVA-SVR model, with excellent results for V, Cr, Cu, Zn, Mo, Cd and Pb estimates, and the R-2 values were 0.993, 0.996, 0.999, 0.999, 0.997, 0.998 and 0.998 respectively. Therefore, the new framework proposed in this paper can effectively eliminate redundant features and determine the concentration of trace elements in soil. It provides an effective alternative for the quantitative analysis of X-ray fluorescence spectrometry.
引用
收藏
页码:3944 / 3952
页数:10
相关论文
共 50 条
  • [31] Quantitative determination of metals in radish using x-ray fluorescence spectrometry
    Anjos, MJ
    Lopes, RT
    Jesus, EFO
    Simabuco, SM
    Cesareo, R
    X-RAY SPECTROMETRY, 2002, 31 (02) : 120 - 123
  • [32] Comparative study of X-ray fluorescence and inductively coupled plasma optical emission spectrometry of heavy metals in the analysis of soil samples
    Krishna, A. Keshav
    Mohan, K. Rama
    Murthy, N. N.
    Govil, P. K.
    ATOMIC SPECTROSCOPY, 2008, 29 (03) : 83 - 89
  • [33] Preparation of Samples for X-ray Fluorescence Analysis for Determining Traces of Heavy Metals in Foodstuffs.
    Scheubeck, Egmont
    Joerrens, Charlotte
    Siemens Forschungs- und Entwicklungsberichte/Siemens Research and Development Reports, 1981, 10 (01): : 29 - 33
  • [34] QUANTITATIVE FLUORINE DETERMINATION BY X-RAY FLUORESCENCE ANALYSIS
    JECHT, U
    CHEMIKER-ZEITUNG, 1972, 96 (02): : 104 - &
  • [35] Research in quantitative microscopic X-ray fluorescence analysis
    Lankosz, M
    Szczerbowska-Boruchowska, M
    Chwiej, J
    Ostachowicz, J
    Simionovici, A
    Bohic, S
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (10-11) : 1517 - 1521
  • [36] Online X-ray Fluorescence (XRF) Analysis of Heavy Metals in Pulverized Coal on a Conveyor Belt
    Zhang Yan
    Zhang XinLei
    Jia WenBao
    Shan Qing
    Ling YongSheng
    Hei DaQian
    Chen Da
    APPLIED SPECTROSCOPY, 2016, 70 (02) : 272 - 278
  • [37] Polychromatic and Microfocused X-ray Radiation for Traceable Quantitative X-ray Fluorescence Analysis
    Kayser, Yves
    Unterumsberger, Rainer
    Waehlisch, Andre
    Bzheumikhova, Karina
    Hoenicke, Philipp
    Zech, Claudia
    Beckhoff, Burkhard
    SPECTROSCOPY, 2021, 36 : 13 - 16
  • [38] Quantification of toxic metals in cropland soil using X-ray fluorescence
    Mvelase, Mashinga J.
    Masiteng, Paulus L.
    SOUTH AFRICAN JOURNAL OF SCIENCE, 2023, 119 (9-10)
  • [39] Subsurface measurement of soil heavy-metal concentrations with the SCAPS X-ray fluorescence (XRF) metals sensor
    Elam, WT
    Adams, JW
    Hudson, KR
    McDonald, B
    Gilfrich, JV
    FIELD ANALYTICAL CHEMISTRY AND TECHNOLOGY, 1998, 2 (02): : 97 - 102
  • [40] Concentration and X-ray fluorescence determination of heavy metals on impregnated cellulose filters
    Z. A. Temerdashev
    Dzh. N. Konshina
    D. I. Salov
    V. V. Konshin
    Inorganic Materials, 2011, 47 : 1619 - 1622