Speckle Reduction in Swept Source Optical Coherence Tomography Images with Slow-axis Averaging

被引:2
|
作者
Tan, Ou [1 ,2 ]
Li, Yan [1 ,2 ]
Wang, Yimin [1 ,2 ]
Kraus, Martin F. [3 ,4 ,5 ,6 ]
Liu, Jonathan J. [3 ,4 ]
Potsaid, Benjamin [3 ,4 ,7 ]
Baumann, Bernhard [3 ,4 ,8 ]
Fujimoto, James G. [3 ,4 ]
Huang, David [1 ,2 ]
机构
[1] Oregon Hlth & Sci Univ, Dept Ophthal, Portland, OR 97239 USA
[2] Oregon Hlth & Sci Univ, Casey Eye Inst, Portland, OR 97239 USA
[3] MIT, Res Lab Elect, Cambridge, MA USA
[4] MIT, Dept EECS, Cambridge, MA USA
[5] Univ Erlangen Nurnberg, Sch Adv Opt Technol SAOT, Nurnberg, Germany
[6] Univ Erlangen Nurnberg, Pattern Recognit Lab, Nurnberg, Germany
[7] Thorlabs Inc, Adv Imaging Grp, Newton, NJ USA
[8] Tufts Univ, New England Eye Ctr, Boston, MA USA
关键词
Swept Source Optical Coherence Tomography; Speckle Reduction; Frame Averaging; Contrast-to-noise Ratio; Slow-axis Averaging; ANTERIOR SEGMENT; NOISE-REDUCTION; 2ND; SCANS; EYE; FILTER;
D O I
10.1117/12.911735
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The effectiveness of speckle reduction using traditional frame averaging technique was limited in ultrahigh speed optical coherence tomography (OCT). As the motion between repeated frames was very small, the speckle pattern of the frames might be identical. This problem could be solved by averaging frames acquired at slightly different locations. The optimized scan range depended on the spot size of the laser beam, the smoothness of the boundary, and the homogeneity of the tissue. In this study we presented a method to average frames obtained within a narrow range along the slow-axis. A swept-source OCT with 100,000 Hz axial scan rate was used to scan the retina in vivo. A series of narrow raster scans (0-50 micron along the slow axis) were evaluated. Each scan contained 20 image frames evenly distributed in the scan range. The imaging frame rate was 417 HZ. Only frames with high correlation after rigid registration were used in averaging. The result showed that the contrast-to-noise ratio (CNR) increased with the scan range. But the best edge reservation was obtained with 15 micron scan range. Thus, for ultrahigh speed OCT systems, averaging frames from a narrow band along the slow-axis could achieve better speckle reduction than traditional frame averaging techniques.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Speckle noise reduction in swept-source optical coherence tomography by retinal image registration
    Cai Huai-yu
    Han Xiao-yan
    Lou Shi-liang
    Wang Yi
    Chen Wen-guang
    Chen Xiao-dong
    [J]. CHINESE OPTICS, 2021, 14 (02): : 289 - 297
  • [2] A new algorithm for speckle reduction of optical coherence tomography images
    Avanaki, Mohammad R. N.
    Marques, Manuel J.
    Bradu, Adrian
    Hojjatoleslami, Ali
    Podoleanu, Adrian Gh.
    [J]. OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVIII, 2014, 8934
  • [3] Speckle variance detection of microvasculature using swept-source optical coherence tomography
    Mariampillai, Adrian
    Standish, Beau A.
    Moriyama, Eduardo H.
    Khurana, Mamta
    Munce, Nigel R.
    Leung, Michael K. K.
    Jiang, James
    Cable, Alex
    Wilson, Brian C.
    Vitkin, I. Alex
    Yang, Victor X. D.
    [J]. OPTICS LETTERS, 2008, 33 (13) : 1530 - 1532
  • [4] Speckle reduction in optical coherence tomography
    School of Information Engineering, Beijing Institute of Technology, Beijing 100081, China
    不详
    不详
    [J]. Zhongguo Jiguang, 2008, 9 (1437-1440):
  • [5] A directional multiscale approach for speckle reduction in optical coherence tomography images
    Forouzanfar, M.
    Moghaddarn, H. A.
    [J]. 2007 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, 2007, : 266 - 271
  • [6] Speckle reduction in optical coherence tomography images based on wave atoms
    Du, Yongzhao
    Liu, Gangjun
    Feng, Guoying
    Chen, Zhongping
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (05)
  • [7] Speckle reduction in optical coherence tomography images using digital filtering
    Ozcan, Aydogan
    Bilenca, Alberto
    Desjardins, Adrien E.
    Bouma, Brett E.
    Tearney, Guillermo J.
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (07) : 1901 - 1910
  • [8] Speckle Noise Reduction of Optical Coherence Tomography Images with a Wavelet Transform
    Murakami, Tsuyoshi
    Ogawa, Koichi
    [J]. 2018 IEEE 14TH INTERNATIONAL COLLOQUIUM ON SIGNAL PROCESSING & ITS APPLICATIONS (CSPA 2018), 2018, : 31 - 34
  • [9] Speckle Reduction for Optical Coherence Tomography Images Based on Local Variance
    Yang, Na
    Shi, Guohua
    Yang, Ting
    Wang, Lirong
    [J]. 2017 10TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI), 2017,
  • [10] Speckle reduction in optical coherence tomography images using tissue viscoelasticity
    Kennedy, Brendan F.
    Curatolo, Andrea
    Hillman, Timothy R.
    Saunders, Christobel M.
    Sampson, David D.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (02)