摘要
An integrated water quality management system involves both treatment of wastewater and appropriate reuse of the effluent. Treated wastewater from commercial establishments such as hotels, high-rise residential or office buildings and shopping malls are potential source of non-potable water for use as landscape watering and toilet flushing. This study aimed to determine the performance of a full-scale aerobic activated sludge system and a bench-scale attached growth anoxic-aerobic growth wastewater treatment system (WWTS) which operated at shorter HIRT and higher organic loading rate (OLR) than the present full-scale system. The effect of HRT on the bench-scale performance was also determined. Furthermore, it assessed the effluent water quality for possible reuse. In the full-scale WWTS, at 2.06 +/- 0.18 days HRT and 0.396 +/- 0.123 kg COD/OLR, the COD, BOD, FOG and TSS removal efficiency were 97.2 +/- 2.3%, 95.3 +/- 2.0%, 91.6 +/- 15.0% and 85.96 +/- 13.4%, respectively. In the bench-scale attached growth anaerobic-aerobic WWTS, the BOD, COD, FOG and TSS removal efficiency were 97.9 +/- 2.3%, 93.6 +/- 5.9%, 87.8 +/- 22.9% and 71.4 +/- 18.5%, respectively, at 6.35 h HRT and 2.42 +/- 0.40 kg COD/OLR. The efficiencies were better at longer HRT and lower OLR. At 12.70 h HRT and 1.50 +/- 0.30 kg COD/OLR, the BOD, COD, FOG and TSS removal efficiencies were 98.1 +/- 2.4%, 94.7 +/- 4.6%, 95.0 +/- 5.1% and 91.4 +/- 2.4%, respectively. The effluent of the bench-scale WWTS after an additional tertiary treatment could be used for landscape watering and flushing toilet.
引用
收藏
页码:476 / 482
页数:7
相关论文
共 50 条
  • [21] Beer and soft drinks industry wastewater treatment using an anoxic-aerobic membrane bioreactor (MBR) coupling with nanofiltration in Sahelian context
    Sawadogo, B.
    Konate, Y.
    Lesage, G.
    Djanni, H. Moungoue
    Zaviska, F.
    Heran, M.
    Karambiri, H.
    DESALINATION AND WATER TREATMENT, 2018, 126 : 32 - 39
  • [22] Evaluation of eventual toxicities of treated textile wastewater using anoxic-aerobic algal-bacterial photobioreactor
    Dhaouefi, Zaineb
    Lahmar, Aida
    Khlifi, Rihab
    Ben Toumia, Imene
    Elgueder, Dorra
    Chekir-Ghedira, Leila
    ENVIRONMENTAL GEOCHEMISTRY AND HEALTH, 2022, 44 (12) : 4285 - 4297
  • [23] Treatment of wastewater using an integrated submerged attached growth system
    Ezechi, Ezerie Henry
    Kutty, Shamsul Rahman Bin Mohamed
    Isa, Mohamed Hasnain
    Abd Rahim, Ahmad Fitri
    STRUCTURAL, ENVIRONMENTAL, COASTAL AND OFFSHORE ENGINEERING, 2014, 567 : 167 - 171
  • [24] Treatment of a slaughterhouse wastewater by anoxic-aerobic biological reactors followed by UV-C disinfection and microalgae bioremediation
    Svierzoski, Nicoly Dal Santo
    Matheus, Mauricio Carvalho
    Bassin, Joao Paulo
    Brito, Yves Dias
    Mahler, Claudio Fernando
    Webler, Alberto Dresch
    WATER ENVIRONMENT RESEARCH, 2021, 93 (03) : 409 - 420
  • [25] Effects of ZnO nanoparticle exposure on wastewater treatment and soluble microbial products (SMPs) in an anoxic-aerobic membrane bioreactor
    Zhang, Dong Qing
    Eng, Chin Yee
    Stuckey, David C.
    Zhou, Yan
    CHEMOSPHERE, 2017, 171 : 446 - 459
  • [26] Full-scale Anoxic-Aerobic SBR System for Simultaneous Nitrogen and Phosphorus Removal from Municipal Wastewater
    Li, Chao
    Ji, Min
    Li, Xin
    Song, Yanqing
    Zhang, Yifan
    Li, Wei
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [27] The implementation of single-sludge step-feed anoxic-aerobic process in a domestic wastewater treatment plant
    Xu, Aotian
    Young, Stephanie
    Zhang, Yanqiu
    JOURNAL OF ENVIRONMENTAL ENGINEERING AND SCIENCE, 2008, 7 (04) : 417 - 421
  • [28] Textile wastewater treatment in a bench-scale anaerobic-biofilm anoxic-aerobic membrane bioreactor combined with nanofiltration
    Grilli, Selene
    Piscitelli, Daniela
    Mattioli, Davide
    Casu, Stefania
    Spagni, Alessandro
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2011, 46 (13): : 1512 - 1518
  • [29] Revealing the bacterial profile of an anoxic-aerobic moving-bed biofilm reactor system treating a chemical industry wastewater
    Bassin, Joao P.
    Rachid, Caio T. C. C.
    Vilela, Caren
    Cao, Sandra M. S.
    Peixoto, Raquel S.
    Dezotti, Marcia
    INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2017, 120 : 152 - 160
  • [30] Wastewater treatment in recycling system using anaerobic anoxic reactor followed by aerobic reactor with support
    Tratamento de esgoto doméstico em regime de recirculação com utilização de reator anaeróbio anóxico seguido de reator aeróbio com meio suporte
    1600, University Federal de Uberlandia (23):