Repair of Bilateral Quadriceps Tendon Rupture Using a Modified Knotless Suture Anchor and Internal Brace Technique: Surgical Technique and Case Report

被引:2
|
作者
Wang, Xiaoping [1 ,2 ]
Huang, Daoqiang [1 ,2 ]
Feng, Weili [1 ]
Wu, Weiwei [1 ]
Huang, Jian [1 ]
Chen, Luyao [1 ]
Tu, Yumin [1 ]
机构
[1] Southern Med Univ, Dept Orthoped 1, Affiliated Xiaolan Hosp, 65 Jucheng Rd, Zhongshan 528415, Guangdong, Peoples R China
[2] Southern Med Univ, Sch Clin Med 2, Zhongshan, Peoples R China
关键词
internal brace; knotless repair; quadriceps tendon; rupture; simultaneous; STRENGTH;
D O I
10.1111/os.13362
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Quadriceps tendon rupture (QTR) is a rare clinical condition often caused by indirect injury in healthy people. In addition, spontaneous and bilateral ruptures can occur in patients with predisposing factors, such as endocrine or rheumatic disease. Currently, several QTR repair techniques have been proposed; however, no consensus exists about the best repair technique. Case Presentations A 55-year-old man with renal failure secondary to glomerulonephritis suffered from spontaneous bilateral quadriceps tendon ruptures. Based on a knotless suture anchor and internal brace, a novel double-row suture-bridge configuration surgical approach was used to treat the patient. At 11-month follow-up, the patient maintained excellent function, with a Lysholm score of 91 for both knees. Conclusions This technique may be an effective method for repairing ruptured quadriceps tendons.
引用
收藏
页码:2396 / 2401
页数:6
相关论文
共 50 条
  • [21] Distal biceps brachii tendon repair: Suture anchor technique
    Burton, KJ
    Arciero, R
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2003, 11 (01) : 47 - 50
  • [22] Modified Brostrom Technique Using Knotless Suture Anchors
    Bynum, James A.
    Crates, John M.
    Aziz-Jacobo, Jorge
    Barber, F. Alan
    TECHNIQUES IN FOOT AND ANKLE SURGERY, 2010, 9 (01): : 29 - 31
  • [23] Endoscopic Proximal Hamstring Tendon Repair With Knotless Suture-Bridge Technique
    Hsu, Jim C.
    Wilhelm, Christopher V.
    ARTHROSCOPY TECHNIQUES, 2023, 12 (10): : E1737 - E1745
  • [24] Knotless "Suture Staple" Technique for Endoscopic Partial Thickness Abductor Tendon Repair
    Hartigan, David E.
    Mansor, Yosif
    Perets, Itay
    Walsh, John P.
    Mohr, Mitchell R.
    Domb, Benjamin G.
    ARTHROSCOPY TECHNIQUES, 2018, 7 (10): : E975 - E980
  • [25] A novel suture technique in the percutaneous repair of Achilles tendon rupture (TANSEL TECHNIQUE)
    Mutlu, Tansel
    Satilmis, Ahmet Burak
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2020, 11 (02): : 110 - 114
  • [26] Surgical Repair Using Suture Bridge Technique for Triceps Tendon Avulsion
    Furuhata, Ryogo
    Kamata, Yusaku
    Kono, Aki
    Nishimura, Taichi
    Otani, Shinya
    Morioka, Hideo
    CASE REPORTS IN ORTHOPEDICS, 2021, 2021
  • [27] Anatomic Knot Suture Anchor Versus Knotless Suture Anchor Technique for Anterior Talofibular Ligament Repair: A Biomechanical Comparison
    Li, Hong
    Xu, Hanlin
    Hua, Yinghui
    Chen, Wenbo
    Li, Hongyun
    Chen, Shiyi
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2020, 8 (01)
  • [28] Early, Bilateral Re-Rupture of Quadriceps Tendon After Previous Bone-Anchor Repair for Simultaneous, Low-Energy, Bilateral Quadriceps Rupture: A Case Report and Literature Review
    Panagopoulos, Andreas
    Kalavrytinos, Dimitrios
    Giannatos, Vasileios
    Tatani, Irini
    Kouzelis, Antonis
    Kokkalis, Zinon
    AMERICAN JOURNAL OF CASE REPORTS, 2021, 22
  • [29] Simultaneous Bilateral Quadriceps Femoris Tendon Rupture: Case report
    Gunaydin, Pamukcu G.
    Demircan, S.
    Oz, T.
    Otal, Y.
    JOURNAL OF EMERGENCY MEDICINE CASE REPORTS, 2021, 12 (04): : 97 - 99
  • [30] BILATERAL SIMULTANEOUS RUPTURE OF QUADRICEPS TENDON - CASE-REPORT
    NORRIS, MG
    LEVACK, B