Comparison of design features and mechanical properties of commercially available Veress needles

被引:2
|
作者
Schramel, Johannes P. [1 ]
Kindslehner, Angelika [1 ]
Bockstahler, Barbara A. [1 ]
Dupre, Gilles P. [1 ]
机构
[1] Univ Vet Med Vienna, Clin Unit Small Anim Surg, Veterinaerpl 1, A-1210 Vienna, Austria
关键词
D O I
10.1111/vsu.12690
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
ObjectiveTo compare design features and mechanical properties of 13 commercially available Veress needles (VN). Study designIn vitro biomechanical study. Sample populationVeress needles from 9 manufacturers (6 reusable, 6 disposable, and 1 with a reusable stylet combined with a disposable cannula) were included in the study. MethodsVeress needles are designed with a spring-loaded stylet to protect the tip of the cannula following insertion into the abdomen. Stylet forces were measured with a scale in a test jig by moving the stylet in 0.5 mm steps into the hollow cannula. Forces and spring rates were derived from force-displacement plots. Mass, mechanical dimensions, and the bevel angle and geometry were assessed. Differences between VN models were analyzed with a univariate analysis of variance. Results are reported as meanSD or median (range). ResultsPhysical and mechanical parameters differed between models. The exposed stylet length was 3.5 mm (2-7). Three bevel geometries (bias, lancet type, and back-cut) with angles between 20 degrees and 40 degrees were identified. Reusable VN weigh more (24.9 +/- 2.2 g) than disposable designs (6.0 +/- 2.3 g). The mean values for the spring rate and the residual stylet force were 0.23 +/- 0.08 Nmm(-1) and 0.94 +/- 0.28 N, respectively. The mean force required to move the stylet to the cannula tip was 1.81 +/- 0.29 N and 2.77 +/- 0.54 N to move to the proximal end of the bevel. ConclusionCommercially available VN use diverse bevel geometries and have different mechanical characteristics. Studies investigating laparoscopic entry complications should explicitly report the type of VN model used.
引用
收藏
页码:994 / 1001
页数:8
相关论文
共 50 条
  • [21] A COMPARISON OF THE PROPERTIES OF SOME CHLORAMPHENICOL AND NEOMYCIN EYE OINTMENTS, COMMERCIALLY AVAILABLE IN THE UK
    FORD, JL
    RUBINSTEIN, MH
    DUFFY, TD
    IRELAND, DS
    [J]. DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1983, 9 (1-2) : 21 - 33
  • [22] A black and white comparison of commercially available dermatoscopes
    Marson, Justin W.
    Tongdee, Emily
    Chen, Rebecca M.
    Mojeski, Jacob
    Mondok, Christopher
    Schneider, Jane A.
    Siegel, Daniel M.
    [J]. INTERNATIONAL JOURNAL OF DERMATOLOGY, 2023, 62 (10) : E551 - E553
  • [23] Influence of friction stir processing parameters on the mechanical properties of commercially available aluminium tubes
    Kulkarni, Sudhanwa Mahesh
    Mali, Kiran D.
    Kulkarni, Dhananjay M.
    Thiruselvam, Iniyan
    [J]. Interactions, 2024, 245 (01)
  • [24] Comparison of 2 commercially available chlorhexidine mouthrinses
    Keijser, JAM
    Verkade, H
    Timmerman, MF
    Van der Weijden, FA
    [J]. JOURNAL OF PERIODONTOLOGY, 2003, 74 (02) : 214 - 218
  • [25] CLINICAL COMPARISON OF COMMERCIALLY AVAILABLE BIOBRANE PREPARATIONS
    YANG, JY
    TSAI, YC
    NOORDHOFF, MS
    [J]. BURNS, 1989, 15 (03) : 197 - 203
  • [26] A comparison of commercially available software for the prediction of pKa
    Dearden, J. C.
    Cronin, M. T. D.
    Lappin, D. C.
    [J]. JOURNAL OF PHARMACY AND PHARMACOLOGY, 2007, 59 : A7 - A7
  • [27] Testing of mechanical properties of new materials compared to commercially available hip-protectors
    Holzer, G.
    Holzer, L.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2006, 17 : S246 - S246
  • [28] STUDY OF MECHANICAL AND PHYSICAL PROPERTIES OF COMMERCIALLY AVAILABLE ADHESIVELY AND MECHANICALLY BONDED NONWOVEN FABRICS
    ELBEHERY, HM
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1972, : 3 - &
  • [29] A COMPARISON OF COMMERCIALLY AVAILABLE ADJUVANTS FOR USE IN RESEARCH
    BENNETT, B
    CHECK, IJ
    OLSEN, MR
    HUNTER, RL
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1992, 153 (1-2) : 31 - 40
  • [30] COMPARISON OF 4 COMMERCIALLY AVAILABLE CAMP KITS
    VOSSENBERG, J
    MULDER, G
    THIJSSEN, J
    BRUYNZEEL, P
    HAMELINK, M
    KREUKNIET, J
    [J]. JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1979, 17 (09): : 581 - 585