Comparison of design features and mechanical properties of commercially available Veress needles

被引:2
|
作者
Schramel, Johannes P. [1 ]
Kindslehner, Angelika [1 ]
Bockstahler, Barbara A. [1 ]
Dupre, Gilles P. [1 ]
机构
[1] Univ Vet Med Vienna, Clin Unit Small Anim Surg, Veterinaerpl 1, A-1210 Vienna, Austria
关键词
D O I
10.1111/vsu.12690
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
ObjectiveTo compare design features and mechanical properties of 13 commercially available Veress needles (VN). Study designIn vitro biomechanical study. Sample populationVeress needles from 9 manufacturers (6 reusable, 6 disposable, and 1 with a reusable stylet combined with a disposable cannula) were included in the study. MethodsVeress needles are designed with a spring-loaded stylet to protect the tip of the cannula following insertion into the abdomen. Stylet forces were measured with a scale in a test jig by moving the stylet in 0.5 mm steps into the hollow cannula. Forces and spring rates were derived from force-displacement plots. Mass, mechanical dimensions, and the bevel angle and geometry were assessed. Differences between VN models were analyzed with a univariate analysis of variance. Results are reported as meanSD or median (range). ResultsPhysical and mechanical parameters differed between models. The exposed stylet length was 3.5 mm (2-7). Three bevel geometries (bias, lancet type, and back-cut) with angles between 20 degrees and 40 degrees were identified. Reusable VN weigh more (24.9 +/- 2.2 g) than disposable designs (6.0 +/- 2.3 g). The mean values for the spring rate and the residual stylet force were 0.23 +/- 0.08 Nmm(-1) and 0.94 +/- 0.28 N, respectively. The mean force required to move the stylet to the cannula tip was 1.81 +/- 0.29 N and 2.77 +/- 0.54 N to move to the proximal end of the bevel. ConclusionCommercially available VN use diverse bevel geometries and have different mechanical characteristics. Studies investigating laparoscopic entry complications should explicitly report the type of VN model used.
引用
收藏
页码:994 / 1001
页数:8
相关论文
共 50 条
  • [1] Loss of Flexion of EBUS Scope with Needle Insertion: a Comparison of Commercially Available Needles and Systems
    Khan, K. A.
    O'Shea, C.
    Tugwell, J.
    Murphy, P.
    Kennedy, M. P.
    [J]. IRISH JOURNAL OF MEDICAL SCIENCE, 2015, 184 : S517 - S518
  • [2] Evaluation and comparison of mechanical properties between commercially available mini-implants: An in vitro study
    Singh, Alok
    Rathore, Monika
    Govil, Somya
    Umale, Vinay
    Kulshrestha, Rohit
    Singh, Raahat Vikram
    [J]. INTERNATIONAL JOURNAL OF ORTHODONTIC REHABILITATION, 2021, 12 (03) : 98 - 102
  • [3] Mechanical properties of commercially available nylon sutures in the United States
    Callahan, Travis L.
    Lear, William
    Kruzic, Jamie J.
    Maughan, Cory B.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2017, 105 (04) : 815 - 819
  • [4] Sintering effects on the mechanical and chemical properties of commercially available hydroxyapatite
    Cox, FP
    Pomeroy, MJ
    Murphy, ME
    Insley, GM
    [J]. BIOCERAMICS, VOL 16, 2004, 254-2 : 91 - 94
  • [5] A comparison of the mechanical properties of a modified silorane based dental composite with those of commercially available composite material
    Zakir, Muhammad
    Al Kheraif, Abdul Aziz Abdullah
    Asif, Muhammad
    Wong, Ferranti See Leng
    Rehman, Ihtesham Ur
    [J]. DENTAL MATERIALS, 2013, 29 (04) : E53 - E59
  • [6] COMPARISON OF COMMERCIALLY AVAILABLE ANTACIDS
    METZA, K
    ROSCH, W
    [J]. ZEITSCHRIFT FUR GASTROENTEROLOGIE, 1981, 19 (05): : 212 - 221
  • [7] COMPARISON OF PROPERTIES OF COMMERCIALLY AVAILABLE RECOMBINANT AND NATIVE FIREFLY LUCIFERASES
    LEACH, FR
    FORD, SR
    YE, L
    HALL, MS
    [J]. FASEB JOURNAL, 1992, 6 (01): : A332 - A332
  • [8] COMMERCIALLY AVAILABLE PUMPS, A COMPARISON
    不详
    [J]. SVENSK PAPPERSTIDNING-NORDISK CELLULOSA, 1992, 95 (01): : 30 - 32
  • [9] Effect of Mineral Fillers on the Mechanical Properties of Commercially Available Biodegradable Polymers
    Post, Wouter
    Kuijpers, Lambertus J.
    Zijlstra, Martin
    van der Zee, Maarten
    Molenveld, Karin
    [J]. POLYMERS, 2021, 13 (03) : 1 - 14
  • [10] Variability in the Mechanical Properties of Commercially Available Thermally Modified Hardwood Lumber
    Gonzalez, Juan J.
    Bond, Brian
    Quesada, Henry
    [J]. BIORESOURCES, 2021, 16 (03): : 6083 - 6099