Breast DWI at 3 T: influence of the fat-suppression technique on image quality and diagnostic performance

被引:26
|
作者
Nogueira, Luisa [1 ,2 ]
Brandao, Sofia [3 ]
Nunes, Rita G. [4 ]
Ferreira, Hugo Alexandre [4 ]
Loureiro, Joana [3 ]
Ramos, Isabel [2 ]
机构
[1] Polytech Inst Porto ESTS PIPP, Sch Hlth Technol Porto, Dept Radiol, P-4400330 Vila Nova De Gaia, Portugal
[2] Univ Porto, Fac Med, Hosp Sao Joao, Dept Radiol, P-4200319 Oporto, Portugal
[3] Hosp Sao Joao, Dept Radiol, MRI Unit, P-4200319 Oporto, Portugal
[4] Univ Lisbon, Fac Sci, IBEB, P-1749016 Lisbon, Portugal
关键词
APPARENT DIFFUSION-COEFFICIENT; BODY SIGNAL SUPPRESSION; B-VALUES; LESIONS; MRI; BENIGN; WATER; DIFFERENTIATION; CANCER; TISSUE;
D O I
10.1016/j.crad.2014.11.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate two fat-suppression techniques: short tau inversion recovery (STIR) and spectral adiabatic inversion recovery (SPAIR) regarding image quality and diagnostic performance in diffusion-weighted imaging (DWI) of breast lesions at 3 T. MATERIALS AND METHODS: Ninety-two women (mean age 48 +/- 12.1 years; range 21-78 years) underwent breast MRI. Two DWI pulse sequences, with b-values (50 and 1000 s/mm(2)) were performed with STIR and SPAIR. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), suppression homogeneity, and apparent diffusion coefficient (ADC) values were quantitatively assessed for each technique. Values were compared between techniques and lesion type. Receiver operating characteristics (ROC) analysis was used to evaluate lesion discrimination. RESULTS: One hundred and fourteen lesions were analysed (40 benign and 74 malignant). SNR and CNR were significantly higher for DWI-SPAIR; fat-suppression uniformity was better for DWI-STIR (p < 1 x 10(-4)). ADC values for benign and malignant lesions and normal tissue were 1.92 x 10(-3), 1.18 x 10(-3), 1.86 x 10(-3) s/mm(2) for DWI-STIR and 1.80 x 10(-3), 1.11 x 10(-3), 1.79 x 10(-3) s/mm(2) for SPAIR, respectively. Comparison between fat-suppression techniques showed significant differences in mean ADC values for benign (p = 0.013) and malignant lesions (p = 0.001). DWI-STIR and -SPAIR ADC cut-offs were 1.42 x 10(-3) and 1.46 x 10(-3) s/mm(2), respectively. Diagnostic performance for DWI-STIR versus SPAIR was: accuracy (81.6 versus 83.3%), area under curve (87.7 versus 89.2%), sensitivity (79.7 versus 85.1%), and specificity (85 versus 80%). Positive predictive value was similar. CONCLUSION: The fat-saturation technique used in the present study may influence image quality and ADC quantification. Nevertheless, STIR and SPAIR techniques showed similar diagnostic performances, and therefore, both are suitable for use in clinical practice. (C) 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:286 / 294
页数:9
相关论文
共 50 条
  • [41] Diffusion tensor imaging on 3-T MRI breast: diagnostic performance in comparison to diffusion-weighted imaging
    Dalia Abdelhady
    Amany Abdelbary
    Ahmed H. Afifi
    Alaa-eldin Abdelhamid
    Hebatallah H. M. Hassan
    Egyptian Journal of Radiology and Nuclear Medicine, 52
  • [42] Diffusion tensor imaging on 3-T MRI breast: diagnostic performance in comparison to diffusion-weighted imaging
    Abdelhady, Dalia
    Abdelbary, Amany
    Afifi, Ahmed H.
    Abdelhamid, Alaa-eldin
    Hassan, Hebatallah H. M.
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2021, 52 (01):
  • [43] Application of a Novel Iterative Denoising and Image Enhancement Technique in T1-Weighted Precontrast and Postcontrast Gradient Echo Imaging of the Abdomen Improvement of Image Quality and Diagnostic Confidence
    Gassenmaier, Sebastian
    Afat, Saif
    Nickel, Dominik
    Kannengiesser, Stephan
    Herrmann, Judith
    Hoffmann, Ruediger
    Othman, Ahmed E.
    INVESTIGATIVE RADIOLOGY, 2021, 56 (05) : 328 - 334
  • [44] The influence of image quality on diagnostic performance of a machine learning-based fractional flow reserve derived from coronary CT angiography
    Xu, Peng Peng
    Li, Jian Hua
    Zhou, Fan
    Jiang, Meng Di
    Zhou, Chang Sheng
    Lu, Meng Jie
    Tang, Chun Xiang
    Zhang, Xiao Lei
    Yang, Liu
    Zhang, Yuan Xiu
    Wang, Yi Ning
    Zhang, Jia Yin
    Yu, Meng Meng
    Hou, Yang
    Zheng, Min Wen
    Zhang, Bo
    Zhang, Dai Min
    Yi, Yan
    Xu, Lei
    Hu, Xiu Hua
    Liu, Hui
    Lu, Guang Ming
    Ni, Qian Qian
    Zhang, Long Jiang
    EUROPEAN RADIOLOGY, 2020, 30 (05) : 2525 - 2534
  • [45] Isotropic 3D fast spin-echo imaging versus standard 2D imaging at 3.0 T of the knee—image quality and diagnostic performance
    Oliver Ristow
    Lynne Steinbach
    Gregory Sabo
    Roland Krug
    Markus Huber
    Isabel Rauscher
    Ben Ma
    Thomas M. Link
    European Radiology, 2009, 19 : 1263 - 1272
  • [46] Usefulness of two-point Dixon T2-weighted imaging in thyroid-associated ophthalmopathy: comparison with conventional fat saturation imaging in fat suppression quality and staging performance
    Chen, Lu
    Hu, Hao
    Chen, Huan-Huan
    Chen, Wen
    Wu, Qian
    Wu, Fei-Yun
    Xu, Xiao-Quan
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1118):
  • [47] Clinical Feasibility of 3-Dimensional Magnetic Resonance Cholangiopancreatography Using Compressed Sensing Comparison of Image Quality and Diagnostic Performance
    Yoon, Jeong Hee
    Lee, Sang Min
    Kang, Hyo-Jin
    Weiland, Elisabeth
    Raithel, Esther
    Son, Yohan
    Kiefer, Berthold
    Lee, Jeong Min
    INVESTIGATIVE RADIOLOGY, 2017, 52 (10) : 612 - 619
  • [48] Influence of different levels of n-3 supplemented (fish oil) diet on performance, carcass quality and fat status in broilers
    Chashnidel, Y.
    Moravej, H.
    Towhidi, A.
    Asadi, F.
    Zeinodini, S.
    AFRICAN JOURNAL OF BIOTECHNOLOGY, 2010, 9 (05): : 687 - 691
  • [49] Isotropic 3D fast spin-echo imaging versus standard 2D imaging at 3.0 T of the knee-image quality and diagnostic performance
    Ristow, Oliver
    Steinbach, Lynne
    Sabo, Gregory
    Krug, Roland
    Huber, Markus
    Rauscher, Isabel
    Ma, Ben
    Link, Thomas M.
    EUROPEAN RADIOLOGY, 2009, 19 (05) : 1263 - 1272
  • [50] Fat Suppressed Contrast-Enhanced T1-Weighted Dynamic Magnetic Resonance Imaging at 3T: Comparison of Image Quality Between Spectrally Adiabatic Iversion Recovery and the Multiecho Dixon Technique in Imaging of the Prostate
    Iyama, Yuji
    Nakaura, Takeshi
    Kidoh, Masafumi
    Katahira, Kazuhiro
    Namimoto, Tomohiro
    Morishita, Shoji
    Yamashita, Yasuyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (03) : 382 - 387