Breast DWI at 3 T: influence of the fat-suppression technique on image quality and diagnostic performance

被引:26
|
作者
Nogueira, Luisa [1 ,2 ]
Brandao, Sofia [3 ]
Nunes, Rita G. [4 ]
Ferreira, Hugo Alexandre [4 ]
Loureiro, Joana [3 ]
Ramos, Isabel [2 ]
机构
[1] Polytech Inst Porto ESTS PIPP, Sch Hlth Technol Porto, Dept Radiol, P-4400330 Vila Nova De Gaia, Portugal
[2] Univ Porto, Fac Med, Hosp Sao Joao, Dept Radiol, P-4200319 Oporto, Portugal
[3] Hosp Sao Joao, Dept Radiol, MRI Unit, P-4200319 Oporto, Portugal
[4] Univ Lisbon, Fac Sci, IBEB, P-1749016 Lisbon, Portugal
关键词
APPARENT DIFFUSION-COEFFICIENT; BODY SIGNAL SUPPRESSION; B-VALUES; LESIONS; MRI; BENIGN; WATER; DIFFERENTIATION; CANCER; TISSUE;
D O I
10.1016/j.crad.2014.11.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate two fat-suppression techniques: short tau inversion recovery (STIR) and spectral adiabatic inversion recovery (SPAIR) regarding image quality and diagnostic performance in diffusion-weighted imaging (DWI) of breast lesions at 3 T. MATERIALS AND METHODS: Ninety-two women (mean age 48 +/- 12.1 years; range 21-78 years) underwent breast MRI. Two DWI pulse sequences, with b-values (50 and 1000 s/mm(2)) were performed with STIR and SPAIR. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), suppression homogeneity, and apparent diffusion coefficient (ADC) values were quantitatively assessed for each technique. Values were compared between techniques and lesion type. Receiver operating characteristics (ROC) analysis was used to evaluate lesion discrimination. RESULTS: One hundred and fourteen lesions were analysed (40 benign and 74 malignant). SNR and CNR were significantly higher for DWI-SPAIR; fat-suppression uniformity was better for DWI-STIR (p < 1 x 10(-4)). ADC values for benign and malignant lesions and normal tissue were 1.92 x 10(-3), 1.18 x 10(-3), 1.86 x 10(-3) s/mm(2) for DWI-STIR and 1.80 x 10(-3), 1.11 x 10(-3), 1.79 x 10(-3) s/mm(2) for SPAIR, respectively. Comparison between fat-suppression techniques showed significant differences in mean ADC values for benign (p = 0.013) and malignant lesions (p = 0.001). DWI-STIR and -SPAIR ADC cut-offs were 1.42 x 10(-3) and 1.46 x 10(-3) s/mm(2), respectively. Diagnostic performance for DWI-STIR versus SPAIR was: accuracy (81.6 versus 83.3%), area under curve (87.7 versus 89.2%), sensitivity (79.7 versus 85.1%), and specificity (85 versus 80%). Positive predictive value was similar. CONCLUSION: The fat-saturation technique used in the present study may influence image quality and ADC quantification. Nevertheless, STIR and SPAIR techniques showed similar diagnostic performances, and therefore, both are suitable for use in clinical practice. (C) 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:286 / 294
页数:9
相关论文
共 50 条
  • [1] Fat-Suppression Techniques for 3-T MR Imaging of the Musculoskeletal System
    Del Grande, Filippo
    Santini, Francesco
    Herzka, Daniel A.
    Aro, Michael R.
    Dean, Cooper W.
    Gold, Garry E.
    Carrino, John A.
    RADIOGRAPHICS, 2014, 34 (01) : 217 - 233
  • [2] Is evaluation of the presence of prepectoral edema on T2-weighted with fat-suppression 3 T breast MRI a simple and readily available noninvasive technique for estimation of prognosis in patients with breast cancer?
    Uematsu, Takayoshi
    Kasami, Masako
    Watanabe, Junichiro
    BREAST CANCER, 2014, 21 (06) : 684 - 692
  • [3] Is evaluation of the presence of prepectoral edema on T2-weighted with fat-suppression 3 T breast MRI a simple and readily available noninvasive technique for estimation of prognosis in patients with breast cancer?
    Takayoshi Uematsu
    Masako Kasami
    Junichiro Watanabe
    Breast Cancer, 2014, 21 : 684 - 692
  • [4] Optimization of alternating TR-SSFP for fat-suppression in abdominal images at 3T
    Goncalves, S. I.
    Ziech, M. L. W.
    Lamerichs, R.
    Stoker, J.
    Nederveen, A. J.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (03) : 595 - 600
  • [5] Image quality and diagnostic performance of deep learning reconstruction for diffusion- weighted imaging in 3 T breast MRI
    Lee, Eun Ji
    Chang, Yun-Woo
    Lee, Eun Hye
    Cha, Jang Gyu
    Kim, Shin Young
    Choi, Nami
    Paek, Munyoung
    Darwish, Omar
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 185
  • [6] Diffusion-weighted magnetic resonance imaging of breast lesions: the influence of different fat-suppression techniques on quantitative measurements and their reproducibility
    P. Mürtz
    M. Tsesarskiy
    A. Kowal
    F. Träber
    J. Gieseke
    W. A. Willinek
    C. C. Leutner
    A. Schmiedel
    H. H. Schild
    European Radiology, 2014, 24 : 2540 - 2551
  • [7] Image quality and evaluation ability of magnetic resonance imaging techniques for thyroid-associated ophthalmopathy: Dixon fat-suppression technique vs. spectral attenuated inversion recovery
    Huang, Kai
    Lin, Xiaoxin
    Luo, Yaosheng
    Hu, Qiugen
    Guo, Baoliang
    Ouyang, Fusheng
    Ouyang, Yufeng
    Song, Cheng
    Chen, Haixiong
    FRONTIERS IN MEDICINE, 2023, 10
  • [8] Diffusion-weighted magnetic resonance imaging of breast lesions: the influence of different fat-suppression techniques on quantitative measurements and their reproducibility
    Muertz, P.
    Tsesarskiy, M.
    Kowal, A.
    Traeber, F.
    Gieseke, J.
    Willinek, W. A.
    Leutner, C. C.
    Schmiedel, A.
    Schild, H. H.
    EUROPEAN RADIOLOGY, 2014, 24 (10) : 2540 - 2551
  • [9] Bilateral breast MRI by use of dual-source parallel radiofrequency excitation and image-based shimming at 3 Tesla: improvement in homogeneity on fat-suppression imaging
    Ishizaka K.
    Kato F.
    Terae S.
    Mito S.
    Oyama-Manabe N.
    Kamishima T.
    Nakanishi M.
    Sugimori H.
    Hamaguchi H.
    Shirato H.
    Radiological Physics and Technology, 2015, 8 (1) : 4 - 12
  • [10] Diffusion-Weighted Imaging of the Head and Neck: Influence of Fat-Suppression Technique and Multishot 2D Navigated Interleaved Acquisitions
    Bae, Y. J.
    Choi, B. S.
    Jeong, H. -K.
    Sunwoo, L.
    Jung, C.
    Kim, J. H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (01) : 145 - 150