Application of infrared thermography for the determination of the overall heat transfer coefficient (U-Value) in building envelopes

被引:215
|
作者
Fokaides, Paris A. [2 ]
Kalogirou, Soteris A. [1 ]
机构
[1] Cyprus Univ Technol, Dept Mech Engn & Mat Sci & Engn, CY-3603 Limassol, Cyprus
[2] Univ Cyprus, Dept Civil & Environm Engn, Nicosia, Cyprus
关键词
Infrared (IR) thermography; Overall heat transfer coefficient (U-Value); Sensitivity analysis; Thermal emissivity; Reflected temperature;
D O I
10.1016/j.apenergy.2011.05.014
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Infrared (IR) thermography constitutes a reliable measurement method for the determination of spatially resolved surface temperature distributions. IR thermography may be used for several research problems, applications, and measurement environments with a variety of physical arrangements. In this work the results of the determination of the overall heat transfer coefficient (U-Value) with the use of IR thermography for building envelopes are presented. The obtained U-Values are validated by means of measurements performed with the use of a thermohygrometer for two seasons (summer and winter), as well as with the notional results provided by the relevant EN standard. Issues related to the applicability of the method due to the non-steady heat transfer phenomena observed at building shells are also discussed. A more precise validation of the proposed technique was also performed with the use of heat flux meters. The percentage absolute deviation between the notional and the measured U-Values for IR thermography is found to be in an acceptable level, in the range of 10-20%. Finally, a sensitivity analysis is conducted in order to define the most important parameters which may have a significant influence on the measurement accuracy. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4358 / 4365
页数:8
相关论文
共 50 条
  • [1] Approach for external measurements of the heat transfer coefficient (U-value) of building envelope components using UAV based infrared thermography
    Patel, D.
    Schmiedt, J. Estevam
    Roeger, M.
    Hoffschmidt, B.
    [J]. 14TH QUANTITATIVE INFRARED THERMOGRAPHY CONFERENCE, 2018, : 379 - 386
  • [2] Determining overall heat transfer coefficient (U-Value) of wood-framed wall assemblies in Canada using external infrared thermography
    Mahmoodzadeh, Milad
    Gretka, Voytek
    Hay, Katie
    Steele, Casey
    Mukhopadhyaya, Phalguni
    [J]. BUILDING AND ENVIRONMENT, 2021, 199 (199)
  • [3] A Comparative Study Between Jordanian Overall Heat Transfer Coefficient (U-Value) and International Building Codes
    Alkhalidi, Ammar
    Kiwan, Suhil
    Hamasha, Haya
    [J]. 2019 10TH INTERNATIONAL RENEWABLE ENERGY CONGRESS (IREC), 2019,
  • [4] A New Method of Pixel-Level In Situ U-Value Measurement for Building Envelopes Based on Infrared Thermography
    Wang, Zihao
    Hou, Yu
    Soibelman, Lucio
    [J]. COMPUTING IN CIVIL ENGINEERING 2023-RESILIENCE, SAFETY, AND SUSTAINABILITY, 2024, : 697 - 704
  • [5] UNCERTAINTY QUANTIFICATION OF OVERALL HEAT TRANSFER COEFFICIENT(U-VALUE) FOR A GLAZING SYSTEM WITH EXTERNAL VENETIAN BLIND
    Lee, Jeong Yun
    Park, Cheol Soo
    [J]. 2023 ANNUAL MODELING AND SIMULATION CONFERENCE, ANNSIM, 2023, : 607 - 615
  • [6] In-situ U-value measurements of typical building envelopes in a severe cold region of China: U-value variations and energy Implications
    Yu, Jiaqi
    Chang, Wen-Shao
    Zhang, Ruinan
    Dong, Yu
    Huang, Haoyu
    Wang, Tsung-Hsien
    [J]. Energy and Buildings, 2024, 324
  • [7] Evaluation of aerial thermography for measuring the thermal transmittance (U-value) of a building façade
    Videras Rodríguez, Marta
    Gómez Melgar, Sergio
    Andújar Márquez, José Manuel
    [J]. Energy and Buildings, 2024, 324
  • [8] A SIMPLIFIED OVERALL THERMAL TRANSFER VALUE EQUATION FOR BUILDING ENVELOPES
    CHOU, SK
    LEE, YK
    [J]. ENERGY, 1988, 13 (08) : 657 - 670
  • [9] In-situ U-value monitoring of highly insulated building envelopes: Review and experimental investigation
    O'Hegarty, R.
    Kinnane, O.
    Lennon, D.
    Colclough, S.
    [J]. ENERGY AND BUILDINGS, 2021, 252
  • [10] In situ U-value measurement of building envelopes through continuous low-cost monitoring
    Mobaraki, Behnam
    Pascual, Francisco Javier Castilla
    Lozano-Galant, Fidel
    Lozano-Galant, Jose Antonio
    Soriano, Rocio Porras
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2023, 43