Approach for external measurements of the heat transfer coefficient (U-value) of building envelope components using UAV based infrared thermography

被引:5
|
作者
Patel, D. [1 ]
Schmiedt, J. Estevam [2 ]
Roeger, M. [3 ]
Hoffschmidt, B. [2 ]
机构
[1] German Aerosp Ctr DLR, Inst Solar Res, Karl Heinz Beckurts Str 13, D-52428 Cologne, Germany
[2] German Aerosp Ctr DLR, Inst Solar Res, D-51147 Cologne, Germany
[3] German Aerosp Ctr DLR, Inst Solar Res, Plataforma Solar De Alme 04200, Spain
关键词
D O I
10.21611/qirt.2018.026
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A high share of heating energy consumption by buildings is due to poorly insulated building envelopes. Identification of poorly insulated building envelopes is still a challenge. Nowadays, remote sensing equipment has become increasingly inexpensive and accessible. This paper evaluates the potential of using unmanned aerial vehicles (UAVs) carried equipment for quantitative analysis of the thermal properties of building envelopes. A comprehensive uncertainty analysis of the U-value measurement is conducted. In the uncertainty budget, an error in temperature measurement with IR camera contributes the largest share of uncertainty. Additionally, IRT measurements are compared with the heat flux meter (HFM) method.
引用
收藏
页码:379 / 386
页数:8
相关论文
共 38 条
  • [1] Application of infrared thermography for the determination of the overall heat transfer coefficient (U-Value) in building envelopes
    Fokaides, Paris A.
    Kalogirou, Soteris A.
    [J]. APPLIED ENERGY, 2011, 88 (12) : 4358 - 4365
  • [2] Determining overall heat transfer coefficient (U-Value) of wood-framed wall assemblies in Canada using external infrared thermography
    Mahmoodzadeh, Milad
    Gretka, Voytek
    Hay, Katie
    Steele, Casey
    Mukhopadhyaya, Phalguni
    [J]. BUILDING AND ENVIRONMENT, 2021, 199
  • [3] A Model Calibration Approach to U-Value Measurements with Thermography
    Patel, Dhruvkumar
    Schmiedt, Jacob Estevam
    Roeger, Marc
    Hoffschmidt, Bernhard
    [J]. BUILDINGS, 2023, 13 (09)
  • [4] Heat Transfer Coefficient Measurements using Infrared Thermography Technique
    Simionescu, Stefan-Mugur
    Duzel, Umran
    Esposito, Claudia
    Ilich, Zdenek
    Balan, Corneliu
    [J]. 2015 9TH INTERNATIONAL SYMPOSIUM ON ADVANCED TOPICS IN ELECTRICAL ENGINEERING (ATEE), 2015, : 591 - 596
  • [5] UNCERTAINTY QUANTIFICATION OF OVERALL HEAT TRANSFER COEFFICIENT(U-VALUE) FOR A GLAZING SYSTEM WITH EXTERNAL VENETIAN BLIND
    Lee, Jeong Yun
    Park, Cheol Soo
    [J]. 2023 ANNUAL MODELING AND SIMULATION CONFERENCE, ANNSIM, 2023, : 607 - 615
  • [6] A Comparative Study Between Jordanian Overall Heat Transfer Coefficient (U-Value) and International Building Codes
    Alkhalidi, Ammar
    Kiwan, Suhil
    Hamasha, Haya
    [J]. 2019 10TH INTERNATIONAL RENEWABLE ENERGY CONGRESS (IREC), 2019,
  • [7] A New Method of Pixel-Level In Situ U-Value Measurement for Building Envelopes Based on Infrared Thermography
    Wang, Zihao
    Hou, Yu
    Soibelman, Lucio
    [J]. COMPUTING IN CIVIL ENGINEERING 2023-RESILIENCE, SAFETY, AND SUSTAINABILITY, 2024, : 697 - 704
  • [8] Variations in the U-Value Measurement of a Whole Dwelling Using Infrared Thermography under Controlled Conditions
    Marshall, Alex
    Francou, Johann
    Fitton, Richard
    Swan, William
    Owen, Jacob
    Benjaber, Moaad
    [J]. BUILDINGS, 2018, 8 (03)
  • [9] USING INFRARED THERMOGRAPHY TO STUDY BUILDING HEAT-TRANSFER
    ARASTEH, DK
    BECK, FA
    GRIFFITH, BT
    BYARS, N
    ACEVEDORUIZ, M
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1992, 34 (10): : 34 - &
  • [10] Heat Transfer Measurements in an Expansion Tube Using Infrared Thermography
    Ramesh, Ranjini
    Morgan, Richard G.
    Mee, David J.
    [J]. AIAA JOURNAL, 2022, 60 (02) : 883 - 891