Quantification of estrogen concentration in a creek receiving wastewater treatment plant effluent

被引:7
|
作者
Adeyeye, Adebayo O. [1 ]
Laub, Brian G. [1 ]
机构
[1] Univ Texas San Antonio, Coll Sci, Dept Environm Sci & Ecol, One UTSA Circle, San Antonio, TX 78249 USA
关键词
Estradiol; Ethynylestradiol; Cibolo Creek; Wastewater treatment plant (WWTP) effluent; Water quality; PERSONAL CARE PRODUCTS; ENDOCRINE-DISRUPTING CHEMICALS; SURFACE-WATER; ENVIRONMENTAL-IMPACT; SLUDGE TREATMENT; PHARMACEUTICALS; FATE; CONTAMINANTS; REMOVAL; RIVER;
D O I
10.1007/s10661-020-08394-z
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Estrogen in streams threatens aquatic animals, especially where wastewater treatment plant (WWTP) effluent contributes to baseflow. We investigated total estrogen (E1+E2+E3) as estradiol equivalent (E2) and ethynylestradiol (EE2) concentration in Cibolo Creek (Cibolo), a groundwater-fed stream near San Antonio, TX, receiving effluent via two WWTP. We collected water samples bi-monthly from late spring to early fall 2018 in Cibolo and WWTP effluent, and used ELISA analysis and discharge measurements to determine concentrations and loads of estrogens. We measured several environmental variables to investigate what factors influenced estrogen concentrations in Cibolo downstream from WWTP inputs. Mean concentrations of WWTP effluent (E2, 41.43 +/- 15.48; EE2, 11.40 +/- 2.07 ng L-1) were higher compared with concentrations in Cibolo, both downstream (E2, 30.09 +/- 25.85; EE2, 6.33 +/- 1.92 ng L-1) and upstream (E2, 12.91 +/- 11.12; EE2, 4.5 +/- 1.38 ng L-1) of WWTP inputs. Both E2 and EE2 concentrations decreased downstream from WWTP inputs, a section of stream without large quantities of fine sediments for sorption, indicating potential dilution or chemical and biological degradation. Effluent into Cibolo via the first, and older, WWTP contributed the most estrogen load in Cibolo. Median concentrations of E2 and EE2 were 19 and 5 ng L-1, respectively, downstream of WWTP inputs, concentrations known to affect reproductive processes of aquatic biota and impair human health. Results suggest estrogens may pose a risk to aquatic ecosystems wherever WWTP effluent comprises a majority of baseflow, though further studies are required in this stream to verify biological impacts.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Characterization and toxicity of nanoscale fragments in wastewater treatment plant effluent
    Hu, Xiangang
    Ren, Chaoxiu
    Kang, Weilu
    Mu, Li
    Liu, Xiaowei
    Li, Xiaokang
    Wang, Tong
    Zhou, Qixing
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 626 : 1332 - 1341
  • [42] Investigation of microplastics in advanced biological wastewater treatment plant effluent
    Arslan, Ayla
    Topkaya, Eylem
    Sezer, Mesut
    Aksan, Serdar
    Veli, Sevil
    [J]. MARINE POLLUTION BULLETIN, 2024, 203
  • [43] Electrochemical disinfection of secondary wastewater treatment plant (WWTP) effluent
    Perez, G.
    Gomez, P.
    Ibanez, R.
    Ortiz, I.
    Urtiaga, A. M.
    [J]. WATER SCIENCE AND TECHNOLOGY, 2010, 62 (04) : 892 - 897
  • [44] Effect of ozonation on the biodegradability urban wastewater treatment plant effluent
    Phan, Lam Thanh
    Schaar, Heidemarie
    Saracevic, Ernis
    Krampe, Jorg
    Kreuzinger, Norbert
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 812
  • [45] Simulation of a wastewater treatment plant receiving industrial effluents
    Mhlanga, F. T.
    Brouckaert, C. J.
    Foxon, K. M.
    Fennemore, C.
    Mzulwini, D.
    Buckley, C. A.
    [J]. WATER SA, 2009, 35 (04) : 447 - 454
  • [46] PHYSICO-CHEMICAL LIMNOLOGY AND PERIPHYTON IN A WARM-WATER STREAM RECEIVING WASTEWATER TREATMENT PLANT EFFLUENT.
    Brigham, Allison Roeske
    Larimore, R.Weldon
    [J]. Physics of Metals and Metallography (English translation of Fizika Metallov i Metallovedenie), 1972, (59):
  • [47] Long-term investigation on the daily variability of microplastic concentration and composition - Monitoring in the effluent of a wastewater treatment plant
    Witzig, Cordula S.
    Fiener, Peter
    Zumbülte, Nicole
    [J]. Science of the Total Environment, 2024, 955
  • [48] Added value of concentration-duration-frequency curves of wastewater treatment plant effluent and river water quality
    Verdonck, FAM
    Rousseau, DPL
    Bixio, D
    Thoeye, C
    Vanrolleghem, PA
    [J]. MODSIM 2003: INTERNATIONAL CONGRESS ON MODELLING AND SIMULATION, VOLS 1-4: VOL 1: NATURAL SYSTEMS, PT 1; VOL 2: NATURAL SYSTEMS, PT 2; VOL 3: SOCIO-ECONOMIC SYSTEMS; VOL 4: GENERAL SYSTEMS, 2003, : 338 - 343
  • [49] COLDWATER-CREEK WASTEWATER TREATMENT PLANT - MISSOURIS LARGEST ACTIVATED SLUDGE PLANT
    LARSON, JW
    [J]. WATER & WASTES ENGINEERING, 1970, 7 (04): : 44 - &
  • [50] The treatment performance of different subsoils in Ireland receiving on-site wastewater effluent
    Gill, L. W.
    P'Sulleabhain, C.
    Misstear, B. D. R.
    Johnston, P. J.
    [J]. JOURNAL OF ENVIRONMENTAL QUALITY, 2007, 36 (06): : 1843 - 1855