Micro-Tomography to Study High-performance Sandwich Structures

被引:12
|
作者
Davies, Peter [1 ]
Choqueuse, Dominique [1 ]
Bourbouze, G. [2 ]
机构
[1] IFREMER, Mat & Struct Grp, F-29280 Plouzane, France
[2] CRT Morlaix, F-29600 Morlaix, France
关键词
inspection; adhesive; meniscus; pins; damage; X-RAY TOMOGRAPHY; COMPUTED-TOMOGRAPHY; HONEYCOMB; COMPOSITES; POLYMER; DELAMINATION; BEHAVIOR; PANELS; DAMAGE; FOAM;
D O I
10.1177/1099636209344273
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Although X-radiography has been widely used in studies of damage in composite materials, micro-tomography has received less attention, due to the high cost and limited availability of equipment. However, micro-tomographic analysis is a powerful tool, allowing 3D images of sections through sandwich materials to be obtained without specimen preparation. Four examples from a recent study are presented here, which show how micro-tomography can provide unique information on the quality of honeycomb sandwich structures, information on damage mechanisms and internal details of through thickness reinforcement in pinned foam cores.
引用
收藏
页码:7 / 21
页数:15
相关论文
共 50 条
  • [21] A PIXE micro-tomography experiment using MLEM algorithm
    Ng, YK
    Orlic, I
    Liew, SC
    Loh, KK
    Tang, SM
    Osipowicz, T
    Watt, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 130 (1-4): : 109 - 112
  • [22] PIXE micro-tomography experiment using MLEM algorithm
    Ng, Y.K.
    Orlic, I.
    Liew, S.C.
    Loh, K.K.
    Tang, S.M.
    Osipowicz, T.
    Watt, F.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1997, 130 (1-4): : 109 - 112
  • [23] Ring Artifact Removal for Micro-Tomography in Synchrotron Radiation
    Pan, Yongsheng
    De Carlo, Francesco
    Xiao, Xianghui
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [24] Micro-tomography via single-pixel imaging
    Peng, Junzheng
    Yao, Manhong
    Cheng, Jiajian
    Zhang, Zibang
    Li, Shiping
    Zheng, Guoan
    Zhong, Jingang
    OPTICS EXPRESS, 2018, 26 (24): : 31094 - 31105
  • [25] Phase Sensitive Micro-Tomography With Asymmetric Bragg Reflection
    Modregger, Peter
    Luebbert, Daniel
    Schaefer, Peter
    Koehler, Rolf
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2006, 62 : S69 - S69
  • [26] Development of fast (sub-minute) micro-tomography
    Uesugi, Kentaro
    Hoshino, Masato
    Takeuchi, Akihisa
    Suzuki, Yoshio
    Yagi, Naoto
    Nakano, Tsukasa
    6TH INTERNATIONAL CONFERENCE ON MEDICAL APPLICATIONS OF SYNCHROTRON RADIATION, 2010, 1266 : 47 - 50
  • [27] Optoacoustic micro-tomography at 100 volumes per second
    X. Luís Deán-Ben
    Hernán López-Schier
    Daniel Razansky
    Scientific Reports, 7
  • [28] Advances in 3D ion micro-tomography
    Sakellariou, A
    Cholewa, M
    Saint, A
    Legge, GJF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 130 (1-4): : 253 - 258
  • [29] Three dimensional imaging of damage in structural materials using high resolution micro-tomography
    Buffière, JY
    Proudhon, H
    Ferrie, E
    Ludwig, W
    Maire, E
    Cloetens, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 238 (1-4): : 75 - 82
  • [30] Optoacoustic micro-tomography at 100 volumes per second
    Dean-Ben, X. Luis
    Lopez-Schier, Hernan
    Razansky, Daniel
    SCIENTIFIC REPORTS, 2017, 7