Association of device-measured physical activity with peak oxygen consumption measured by cardiopulmonary exercise testing in patients with cardiac implantable electronic devices

被引:1
|
作者
Wakabayashi, Yasushi [1 ]
Kobayashi, Masanori [1 ]
Ichikawa, Tomohide [1 ]
Koyama, Takashi [1 ]
Abe, Hidetoshi [1 ]
机构
[1] Matsumoto Kyoritsu Hosp, Dept Cardiovasc Med, 9-26 Habaue, Matsumoto, Nagano 3908505, Japan
关键词
Cardiac implantable electronic device; Cardiopulmonary exercise testing; Device-measured physical activity; Peak oxygen consumption; HEART-FAILURE; MORTALITY; CAPACITY; DISEASE;
D O I
10.1007/s10840-021-01095-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose Cardiac implantable electronic devices (CIEDs) offer diagnostic information such as device-measured physical activity (PA). Peak oxygen consumption (VO2) measured by cardiopulmonary exercise testing (CPET) is the most objective variable showing exercise capacity. The purpose of this study was to investigate the relationship between these 2 variables. Methods We retrospectively studied consecutive patients with CIEDs undergoing CPET between April 1, 2018, and January 31, 2021. These patients were divided into 2 groups: patients with peak VO2 <= 14 ml/kg/min (low peak VO2 group) and those showing peak VO2 > 14 ml/kg/min (high peak VO2 group). The peak device-measured PA was compared between the 2 groups. The relationship between the peak device-measured PA and peak VO2 was also investigated. Results There were 50 and 51 patients in the low and high peak VO2 groups, respectively. The peak device-measured PA, which was expressed in units of hours/day, was significantly lower in the low peak VO2 group than in the high peak VO2 group (3.06, interquartile range [2.43-4.00] vs. 5.50, interquartile range [4.04-6.70] p < 0.01). The peak device-measured PA and peak VO2 showed a significant positive correlation (Spearman's rho = 0.53; p < 0.01). Furthermore, receiver operating characteristic curve analysis showed that a peak device-measured PA > 3.87 h/day could predict high peak VO2 (80.4%, sensitivity; 72.0%, specificity). In multivariate linear regression analysis, peak device-measured PA was an independent predictor of peak VO2 (regression coefficient, 0.61; 95% confidence interval, 0.33-0.89; p < 0.01). Conclusions Peak device-measured PA was significantly associated with peak VO2.
引用
收藏
页码:651 / 659
页数:9
相关论文
共 50 条
  • [21] COMPARISON OF MAXIMAL OXYGEN CONSUMPTION PREDICTED FROM CONSUMER WEARABLES VERSUS MEASURED USING CARDIOPULMONARY EXERCISE TESTING
    Gustus, Sarah
    Shue, Hope
    Churchill, Timothy
    Guseh, James S.
    Vanatta, Carolyn
    Blodgett, Jasmine
    Wasfy, Meagan Murphy
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 2156 - 2156
  • [22] Isotemporal Associations of Device-Measured Sedentary Time and Physical Activity with Cardiac-Autonomic Regulation in Previously Pregnant Women
    Abdullah Bandar Alansare
    Bethany Barone Gibbs
    Claudia Holzman
    J. Richard Jennings
    Christopher E. Kline
    Elizabeth Nagle
    Janet M. Catov
    International Journal of Behavioral Medicine, 2023, 30 : 497 - 508
  • [23] Isotemporal Associations of Device-Measured Sedentary Time and Physical Activity with Cardiac-Autonomic Regulation in Previously Pregnant Women
    Alansare, Abdullah Bandar
    Gibbs, Bethany Barone
    Holzman, Claudia
    Jennings, J. Richard
    Kline, Christopher E.
    Nagle, Elizabeth
    Catov, Janet M.
    INTERNATIONAL JOURNAL OF BEHAVIORAL MEDICINE, 2023, 30 (04) : 497 - 508
  • [24] Associations of device-measured and self-reported physical activity with alcohol consumption: Secondary analyses of a randomized controlled trial (FitForChange)
    Hallgren, Mats
    Moller, Emil Bojsen
    Andreasson, Sven
    Dunstan, David W.
    Vancampfort, Davy
    Ekblom, Orjan
    DRUG AND ALCOHOL DEPENDENCE, 2024, 259
  • [25] Dose-response association between device-measured physical activity and incident dementia: a prospective study from UK Biobank
    Fanny Petermann-Rocha
    Donald M. Lyall
    Stuart R. Gray
    Jason M. R. Gill
    Naveed Sattar
    Paul Welsh
    Terence J. Quinn
    William Stewart
    Jill P. Pell
    Frederick K. Ho
    Carlos Celis-Morales
    BMC Medicine, 19
  • [26] Dose-response association between device-measured physical activity and incident dementia: a prospective study from UK Biobank
    Petermann-Rocha, Fanny
    Lyall, Donald M.
    Gray, Stuart R.
    Gill, Jason M. R.
    Sattar, Naveed
    Welsh, Paul
    Quinn, Terence J.
    Stewart, William
    Pell, Jill P.
    Ho, Frederick K.
    Celis-Morales, Carlos
    BMC MEDICINE, 2021, 19 (01)
  • [27] Cardiac rehabilitation improved oxygen uptake measured by cardiopulmonary exercise test in patients after aortic valve surgery
    Song, Feier
    Zhan, Huimin
    Liang, Yuanfeng
    He, Xuyu
    Guo, Lan
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2019, 20 (01) : 47 - 52
  • [28] Heart rate recovery correlates with peak oxygen consumption in heart failure patients referred for cardiopulmonary exercise testing
    Sheppard, RJ
    Huta, M
    Racine, N
    Rouleau, JL
    Roof, A
    Blanchet, M
    Ducharme, A
    White, M
    JOURNAL OF CARDIAC FAILURE, 2004, 10 (04) : S37 - S37
  • [29] MEASURING PEAK OXYGEN CONSUMPTION IN RENAL TRANSPLANT RECIPIENTS: A COMPARISON OF DUKE ACTIVITY STATUS INDEX WITH CARDIOPULMONARY EXERCISE TESTING
    Billany, Roseanne E.
    Smith, Alice C.
    Fatania, Ganisha J.
    Bishop, Nicolette C.
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2019, 34 : 314 - 314
  • [30] Association Between Device-Measured Physical Activity and Incident Heart Failure: A Prospective Cohort Study of 94 739 UK Biobank Participants
    Ho, Frederick K.
    Zhou, Ziyi
    Petermann-Rocha, Fanny
    Para-Soto, Solange
    Boonpor, Jirapitcha
    Welsh, Paul
    Gill, Jason M. R.
    Gray, Stuart R.
    Sattar, Naveed
    Pell, Jill P.
    Celis-Morales, Carlos
    CIRCULATION, 2022, 146 (12) : 883 - 891