Deterioration Characteristics Due to Partial Discharges in Insulating Structure Constituting Gas-filled Power Transformers

被引:7
|
作者
Okabe, Shigemitsu [1 ]
Ueta, Genyo
Wada, Haruhisa [2 ]
Okubo, Hitoshi [3 ]
机构
[1] Tokyo Elect Power Co Ltd, High Voltage & Insulat Grp, R&D Ctr, Kanagawa 2308510, Japan
[2] Toshiba Co Ltd, Kawasaki Ku, Kanagawa 2100862, Japan
[3] Nagoya Univ, Dept Elect Engn & Comp Sci, Chikusa Ku, Nagoya, Aichi 4648603, Japan
关键词
Gas-filled power transformer; partial discharge (PD); turn-to-turn insulation model; section-to-section insulation model; residual impulse withstand voltage; harmful partial discharge level; insulation degradation;
D O I
10.1109/TDEI.2010.5539691
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The soundness of a transformer under operating voltage is evaluated in a partial discharge (PD) test of a long-duration ac withstand voltage test. Presently, the same criteria for evaluating oil-filled transformers are adopted as those for evaluating gas-filled transformers in this PD test. However, gas-filled transformers are made of different insulating materials than those for oil-filled transformers, and may therefore have different strengths against PDs to oil-filled transformers. With this in mind, it is necessary to establish PD evaluation criteria for gas-filled transformers. A preceding paper discussed the raw materials of solid insulating ones used in gas-filled transformers in terms of the generated PD magnitudes and the degrees of insulation damage and evaluated the harmful PD levels of the insulating materials themselves. In this paper, the harmful PD levels of actual equipment were studied using the turn-to-turn and section-to-section insulation models, insulating structures that constitute gas-filled transformers, in order to examine harmful PD levels that lowered the residual impulse withstand voltages. Consequently, it was confirmed that, on the turn-to-turn insulation model at normal test voltage levels, the generated PDs were too small to damage the insulator, even with a particle present. To damage the insulator, a voltage significantly exceeding the test voltage had to be applied. Therefore there is little necessity to consider the harmful PD level on the turn-to-turn insulation. On the other hand, on the section-to-section insulation model, PDs were found to be generated if a particle completely bridged separate sections. As a result, the degradation statuses related to the magnitude and duration of PDs were identified and the harmful PD levels were estimated at 10000 pC according to the residual impulse withstand voltages.
引用
收藏
页码:1204 / 1213
页数:10
相关论文
共 12 条
  • [1] Partial Discharge-induced Degradation Characteristics of Insulating Materials of Gas-filled Power Transformers
    Okabe, Shigemitsu
    Ueta, Genyo
    Wada, Haruhisa
    Okubo, Hitoshi
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (06) : 1715 - 1723
  • [2] DETERIORATION OF INSULATING MATERIALS DUE TO PARTIAL DISCHARGES IN NITROGEN GAS
    TSUKUI, T
    KAKO, Y
    ELECTRICAL ENGINEERING IN JAPAN, 1972, 92 (04) : 9 - 17
  • [3] Partial Discharge-induced Degradation Characteristics of Insulating Structure Constituting Oil-immersed Power Transformers
    Okabe, Shigemitsu
    Ueta, Genyo
    Wada, Haruhisa
    Okubo, Hitoshi
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (05) : 1649 - 1656
  • [4] Innovation on energy power technology (9): Large capacity gas-filled transformers
    Toda, Katsutoshi
    IEEJ Transactions on Power and Energy, 2008, 128 (08) : 989 - 992
  • [5] Breakdown characteristics of gas-filled transformers and reactors under lightning and switching impulse voltages
    Yamamoto, Takashi
    Ueta, Genyo
    Okabe, Shigemitsu
    Yoshida, Ikki
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2020, 15 (04) : 508 - 512
  • [6] Development of a fibre-optic sensor for partial discharges in oil-filled power transformers
    MacAlpine, M
    Zhao, ZQ
    Demokan, MS
    ELECTRIC POWER SYSTEMS RESEARCH, 2002, 63 (01) : 27 - 36
  • [7] Electromagnetic Wave Radiation Due to Partial Discharges Inside Power Transformers in the Frequency Domain
    Azirani, M. Akbari
    Ariannik, M.
    Werle, P.
    Akbari, A.
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 1, 2020, 598 : 838 - 849
  • [8] Characteristics of gas generation by partial and arc discharges in ester-based insulating oils
    Kato M.
    Oota N.
    Kageyama T.
    Radzi K.B.M.
    Matsumoto S.
    IEEJ Transactions on Fundamentals and Materials, 2021, 141 (03) : 185 - 196
  • [9] Partial Discharge Signal Propagation Characteristics Inside the Winding of Gas-filled Power Transformer - Study Using the Equivalent Circuit of the Winding Model
    Okabe, Shigemitsu
    Ueta, Genyo
    Wada, Haruhisa
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (05) : 1668 - 1677
  • [10] Partial Discharge Signal Propagation Characteristics Inside the Winding of Gas-filled Power Transformer - Experimental Study Using Winding Models in the Air
    Okabe, Shigemitsu
    Ueta, Genyo
    Wada, Haruhisa
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (05) : 1658 - 1667