Active calibration target for bistatic radar cross-section measurements

被引:11
|
作者
Pienaar, M. [1 ]
Odendaal, J. W. [1 ]
Joubert, J. [1 ]
Cilliers, J. E. [2 ]
Smit, J. C. [2 ]
机构
[1] Univ Pretoria, Dept Elect Elect & Comp Engn, Ctr Electromagnetism, Pretoria, South Africa
[2] CSIR, Def Peace Safety & Secur, Pretoria, South Africa
关键词
calibration; bistatic RCS; measurements; COMPLEX OBJECTS; SYSTEMS; RCS;
D O I
10.1002/2015RS005931
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Either passive calibration targets are expensive and complex to manufacture or their bistatic radar cross section (RCS) levels are significantly lower than the monostatic RCS levels of targets such as spheres, dihedral, and trihedral corner reflectors. In this paper the performance of an active calibration target with relative high bistatic RCS values is illustrated as a reference target for bistatic RCS measurements. The reference target is simple to manufacture, operates over a wide frequency range, and can be configured to calibrate all four polarizations (VV, HH, HV, and VH). Bistatic RCS measurements of canonical targets, performed in a controlled environment, are calibrated with the reference target and the results are compared to simulated results using FEKO.