Shear wave elastography in the evaluation of renal parenchymal stiffness in patients with chronic kidney disease

被引:58
|
作者
Leong, Sook Sam [1 ,2 ]
Wong, Jeannie Hsiu Ding [1 ,3 ]
Shah, Mohammad Nazri Md [1 ,3 ]
Vijayananthan, Anushya [1 ,3 ]
Jalalonmuhali, Maisarah [4 ]
Ng, Kwan Hoong [1 ,3 ]
机构
[1] Univ Malaya, Dept Biomed Imaging, Kuala Lumpur, Malaysia
[2] Univ Malaya, Med Ctr, Dept Biomed Imaging, Kuala Lumpur, Malaysia
[3] Univ Malaya, Res Imaging Ctr, Kuala Lumpur, Malaysia
[4] Univ Malaya, Dept Med, Div Nephrol, Kuala Lumpur, Malaysia
来源
BRITISH JOURNAL OF RADIOLOGY | 2018年 / 91卷 / 1089期
关键词
LIVER FIBROSIS; TOOL;
D O I
10.1259/bjr.20180235
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To investigate the use of shear wave elastography (SWE)-derived estimates of Young's modulus (YM) as an indicator to detect abnormal renal tissue diagnosed by estimated glomerular filtration rate (eGFR). Methods: The study comprised 106 chronic kidney disease (CKD) patients and 203 control subjects. Conventional ultrasound was performed to measure the kidney length and cortical thickness. SWE imaging was performed to measure renal parenchymal stiffness. Diagnostic performance of SWE and conventional ultrasound were correlated with serum creatinine, urea levels and eGFR. Results: Pearson's correlation coefficient revealed a negative correlation between YM measurements and eGFR (r = -0.576, p < 0.0001). Positive correlations between YM measurements and age (r = 0.321, p < 0.05), serum creatinine (r = 0.375, p < 00001) and urea (r = 0.287, p < 0.0001) were also observed. The area under the receiver operating characteristic curve for SWE (0.87) was superior to conventional ultrasound alone (0.35-0.37). The cut-off value of less or equal to 4.31 kPa suggested a non-diseased kidney (80.3% sensitivity, 79.5% specificity). Conclusion: SWE was superior to renal length and cortical thickness in detecting CKD. A value of 4.31 kPa or less showed good accuracy in determining whether a kidney was diseased or not. Advances in knowledge: On SWE, CKD patients show greater renal parenchymal stiffness than non-CKD patients. Determining a cut-off value between normal and diseased renal parenchyma may help in early noninvasive detection and management of CKD.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Shear Wave Elastography Findings of Achilles Tendons in Patients on Chronic Hemodialysis and Patients with renal Transplantation
    Rahatli, Feride Kural
    Turnaoglu, Hale
    Haberal, Murat
    Kirnap, Mahir
    Sayin, Burak
    Fidan, Cihan
    Uslu, Nihal
    Haberal, Mehmet
    TRANSPLANTATION, 2018, 102 : S523 - S523
  • [42] Shear wave elastography of the spleen: evaluation of spleen stiffness in healthy volunteers
    Pawlus, Aleksander
    Inglot, Marcin S.
    Szymanska, Kinga
    Kaczorowski, Krzysztof
    Markiewicz, Bartosz D.
    Kaczorowska, Agnieszka
    Gasiorowski, Jacek
    Szymczak, Aleksandra
    Inglot, Magorzata
    Bladowska, Joanna
    Zaleska-Dorobisz, Urszula
    ABDOMINAL RADIOLOGY, 2016, 41 (11) : 2169 - 2174
  • [43] Study of detection times for liver stiffness evaluation by shear wave elastography
    Ze-Ping Huang
    Xin-Ling Zhang
    Jie Zeng
    Jian Zheng
    Ping Wang
    Rong-Qin Zheng
    World Journal of Gastroenterology, 2014, (28) : 9578 - 9584
  • [44] Study of detection times for liver stiffness evaluation by shear wave elastography
    Huang, Ze-Ping
    Zhang, Xin-Ling
    Zeng, Jie
    Zheng, Jian
    Wang, Ping
    Zheng, Rong-Qin
    WORLD JOURNAL OF GASTROENTEROLOGY, 2014, 20 (28) : 9578 - 9584
  • [45] Evaluation of the Stiffness of Tissues Surrounding Thyroid Nodules with Shear Wave Elastography
    Hu, Lei
    He, Nianan
    Ye, Lei
    Zhou, Hangcheng
    Zhong, Wen
    Zhang, Xinshu
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (09) : 2251 - 2260
  • [46] Evaluation of liver and spleen stiffness measurement with shear wave elastography in brucellosis
    Dogan, Ferit
    Celik, Mehmet
    Cosandal, Betul Amasyali
    Turac, Burak
    Ceylan, Mehmet Resat
    Dincer, Nevin Guler
    IRISH JOURNAL OF MEDICAL SCIENCE, 2024, 193 (03) : 1521 - 1526
  • [47] Shear wave elastography of the spleen: evaluation of spleen stiffness in healthy volunteers
    Aleksander Pawluś
    Marcin S. Inglot
    Kinga Szymańska
    Krzysztof Kaczorowski
    Bartosz D. Markiewicz
    Agnieszka Kaczorowska
    Jacek Gąsiorowski
    Aleksandra Szymczak
    Małgorzata Inglot
    Joanna Bladowska
    Urszula Zaleska-Dorobisz
    Abdominal Radiology, 2016, 41 : 2169 - 2174
  • [48] Acoustic radiation force impulse (ARFI) elastography in the evaluation of renal parenchymal stiffness in patients with ureteropelvic junction obstruction
    Habibi, Hatice Arioz
    Cicek, Rumeysa Yasemin
    Kandemirli, Sedat Giray
    Ure, Emel
    Ucar, Ayse Kalyoncu
    Aslan, Mine
    Caliskan, Salim
    Adaletli, Ibrahim
    JOURNAL OF MEDICAL ULTRASONICS, 2017, 44 (02) : 167 - 172
  • [49] Liver stiffness by shear-wave elastography in Alcoholic Liver Disease
    Vonghia, Luisa
    Verlinden, Wim
    Cauwenberghs, Laura
    Steinhauser, Anton
    Van Dongen, Jurgen L.
    Van Marck, Veerle
    Pelckmans, Paul A.
    Michielsen, Peter P.
    Francque, Sven M.
    HEPATOLOGY, 2013, 58 : 958A - 958A
  • [50] Diagnostic accuracy of shear wave elastography in evaluating renal fibrosis in children with chronic kidney disease: a comparative study with nuclear scan
    Abhishek Kumar Yadav
    Poonam Sherwani
    Enono Yhoshu
    Vandana Kumar Dhingra
    Nowneet Kumar Bhat
    Egyptian Journal of Radiology and Nuclear Medicine, 54