Posterior Pituitary Bright Spot Normal Dimensions on MRI

被引:0
|
作者
Iqbal, Sana [1 ]
Umer, Ummara Siddique [2 ]
Sundal, Anisa [2 ]
Jabeen, Mahwish [2 ]
Abdullah [2 ]
Khan, Shandana [1 ]
Nawaz, Aruba [3 ]
Sharif, Aliya [3 ]
机构
[1] Northwest Gen Hosp, Radiol Dept, Peshawar, Pakistan
[2] RMI, Radiol Dept, Peshawar, Pakistan
[3] RMI, Radiol Dept, Radiol, Peshawar, Pakistan
来源
关键词
Pituitary; Magnetic resonance imaging; Posterior pituitary bright spot; GLAND;
D O I
10.53350/pjmhs2216186
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: To assess the measurements of posterior pituitary bright spot on MRI in Khyber Pakhtunkhwa Methods: The study was done in RMI, Peshawar. Duration is January, 2016 to February, 2019. 78 patients with normal pituitary MRI studies were selected for study. MRI without contrast was done along cranio caudal and antero posterior axis on sagital T1WI. Three cases of ectopic posterior pituitary were also included. Results: Dimensions were taken in antero posterior and cranio caudal axis on sagittal T1WI. Dimension of PPBS was 1.8-8.6mm in cranio caudal axis and 0.8-6mm in antero posteriorly. Mean +/- SD of cranio caudal measurement was 5.09 +/- 1.28mm and of antero posteriorly 2.42 +/- 0.9mm. Pearsons analysis showed direct correlation i.e. as value of cranio caudal diameter increased, the antero posteriorly also increased. Conclusion: PPBS was identified in 100% of normal pituitary glands. Mean PPBS size normally ranged from 1.8 to 8mm i.e. mean +/- SD was 5.09 +/- 1.28mm craniocaudally. There is a direct correlation in cranio caudal and antero posterior dimensions of PPBS.
引用
收藏
页码:86 / 87
页数:2
相关论文
共 50 条
  • [21] Imaging in malignant germ cell tumors involving the hypothalamo-neurohypophyseal axis: the evaluation of the posterior pituitary bright spot is essential
    Stock, Annika
    Calaminus, Gabriele
    Weisthoff, Mathilda
    Serfling, Julia
    Pietsch, Torsten
    Bison, Brigitte
    Pham, Mirko
    Warmuth-Metz, Monika
    [J]. NEURORADIOLOGY, 2024, 66 (08) : 1405 - 1416
  • [22] Magnetization transfer imaging of the pituitary: Further insights into the nature of the ''bright spot''
    Holder, CA
    Elster, AD
    [J]. RADIOLOGY, 1996, 201 : 231 - 231
  • [23] THE BRIGHT PITUITARY-GLAND - A NORMAL MR APPEARANCE IN INFANCY
    WOLPERT, SM
    OSBORNE, M
    ANDERSON, M
    RUNGE, VM
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 1988, 9 (01) : 1 - 3
  • [24] 3D TOF MR angiography to depict pituitary bright spot and to detect posterior pituitary lobe cyst: Original description at 3T MR imaging
    Meyrignac, Olivier
    Idir, Ibtir Sam
    Cognard, Christophe
    Bonneville, Jean-Francois
    Bonneville, Fabrice
    [J]. JOURNAL OF NEURORADIOLOGY, 2015, 42 (06) : 321 - 325
  • [25] Bright spot
    [J]. DES, Diesel Equipment Superintendent, 1993, 71 (04):
  • [26] A Bright Spot
    Huyge, Valerie
    Unger, Philippe
    Goldman, Serge
    [J]. AMERICAN JOURNAL OF MEDICINE, 2010, 123 (01): : 37 - 39
  • [27] Bright Spot
    Tatge, M
    [J]. FORBES, 2005, 176 (11): : 194 - +
  • [28] A BRIGHT SPOT
    LAWLOR, T
    [J]. BYTE, 1991, 16 (08): : 20 - 20
  • [29] BRIGHT SPOT
    Barreneche, Raul
    [J]. ARCHITECTURAL DIGEST, 2013, 70 (05) : 176 - 185
  • [30] MRI OF PITUITARY-ADENOMAS - THE POSITION OF THE NORMAL PITUITARY-GLAND
    SUMIDA, M
    UOZUMI, T
    MUKADA, K
    ARITA, K
    KURISU, K
    YANO, T
    ONDA, J
    SATOH, H
    IKAWA, F
    [J]. NEURORADIOLOGY, 1994, 36 (04) : 295 - 297