Validation of Bone Density and Microarchitecture Measurements of the Load-Bearing Femur in the Human Knee Obtained Using In Vivo HR-pQCT Protocol

被引:9
|
作者
Keen, Christopher E. [1 ,2 ]
Whittier, Danielle E. [1 ,2 ]
Firminger, Colin R. [1 ,3 ]
Edwards, W. Brent [1 ,3 ]
Boyd, Steven K. [1 ,2 ,3 ]
机构
[1] Univ Calgary, McCaig Inst Bone & Joint Hlth, Room HRIC 3A16,3280 Hosp Dr NW, Calgary, AB T2N 4Z6, Canada
[2] Univ Calgary, Cumming Sch Med, Dept Radiol, Calgary, AB, Canada
[3] Univ Calgary, Fac Kinesiol, Human Performance Lab, Calgary, AB, Canada
关键词
Accuracy; HR-pQCT; knee; microarchitecture; validation; QUANTITATIVE COMPUTED-TOMOGRAPHY; PRECISION;
D O I
10.1016/j.jocd.2021.01.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
High resolution peripheral quantitative computed tomography (HR-pQCT) was designed to study bone mineral density (BMD) and microarchitecture in peripheral sites at the distal radius and tibia. With the introduction of the second generation HR-pQCT scanner (XtremeCT II, Scanco Medical) that has a larger, longer gantry it is now possible to study the human knee in vivo using HR-pQCT. Previous validation of HR-pQCT measurements at the distal radius and tibia against micro-CT is not representative of the knee because the increased cross-sectional area, greater amount of soft tissue surrounding the scan region, and different imaging protocol result in potentially increased beam hardening effects and photon scatter and different signal-to-noise ratio. The objective of this study is to determine the accuracy of density and microarchitecture measurements in the human knee measured by HR-pQCT using an in vivo protocol. Twelve fresh-frozen cadaver knees were imaged using in vivo HR-pQCT (60.7 mu m) protocol. Subsequentially, distal femurs were extracted and imaged using a higher resolution (30.3 mu m) ex vivo protocol, replicating micro-CT imaging. Scans were registered so that agreement of density and bone microarchitecture measurements could be determined using linear regression and Bland-Altman plots. All density and microarchitecture outcomes were highly correlated between the 2 protocols (R-2 > 0.89) albeit with statistically significant differences between absolute measures based on paired t tests. All parameters showed accuracy between 4.5% and 8.7%, and errors were highly systematic, particularly for trabecular BMD and trabecular thickness (R-2 > 0.93). We found that BMD and microarchitecture measurements in the distal femur obtained using an in vivo HR-pQCT knee protocol contained systematic errors, and accurately represented measurements obtained using a micro-CT equivalent imaging protocol. This work establishes the validity and limitations of using HR-pQCT to study the BMD and microarchitecture of human knees in future clinical studies.
引用
收藏
页码:651 / 657
页数:7
相关论文
共 18 条
  • [11] Bone Geometry, Volumetric Bone Mineral Density, Microarchitecture and Estimated Bone Strength in Caucasian Females with Systemic Lupus Erythematosus. A Cross-Sectional Study Using HR-pQCT
    Hansen, Stinus
    Gudex, Claire
    Ahrberg, Fabian
    Brixen, Kim
    Voss, Anne
    CALCIFIED TISSUE INTERNATIONAL, 2014, 95 (06) : 530 - 539
  • [12] Bone Geometry, Volumetric Bone Mineral Density, Microarchitecture and Estimated Bone Strength in Caucasian Females with Systemic Lupus Erythematosus. A Cross-Sectional Study Using HR-pQCT
    Stinus Hansen
    Claire Gudex
    Fabian Åhrberg
    Kim Brixen
    Anne Voss
    Calcified Tissue International, 2014, 95 : 530 - 539
  • [13] Alterations of bone geometry, density, microarchitecture, and biomechanical properties in systemic lupus erythematosus on long-term glucocorticoid: a case–control study using HR-pQCT
    X. L. Tang
    L. Qin
    A. W. Kwok
    T. Y. Zhu
    E. W. Kun
    V. W. Hung
    J. F. Griffith
    P. C. Leung
    E. K. Li
    L.-S. Tam
    Osteoporosis International, 2013, 24 : 1817 - 1826
  • [14] In vivo Quantification of Intra-cortical Porosity in Human Cortical Bone using HR-pQCT in Patients with type II Diabetes.
    Burghardt, A. J.
    Dais, K. A.
    Masharani, U.
    Link, T. M.
    Majumdar, S.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2008, 23 : S450 - S450
  • [15] Alterations of bone geometry, density, microarchitecture, and biomechanical properties in systemic lupus erythematosus on long-term glucocorticoid: a case-control study using HR-pQCT
    Tang, X. L.
    Qin, L.
    Kwok, A. W.
    Zhu, T. Y.
    Kun, E. W.
    Hung, V. W.
    Griffith, J. F.
    Leung, P. C.
    Li, E. K.
    Tam, L. -S.
    OSTEOPOROSIS INTERNATIONAL, 2013, 24 (06) : 1817 - 1826
  • [16] In vivo analysis of subchondral trabecular bone in patients with osteoarthritis of the knee using second-generation high-resolution peripheral quantitative computed tomography (HR-pQCT)
    Shiraishi, Kazuteru
    Chiba, Ko
    Okazaki, Narihiro
    Yokota, Kazuaki
    Nakazoe, Yusuke
    Kidera, Kenichi
    Yonekura, Akihiko
    Tomita, Masato
    Osaki, Makoto
    BONE, 2020, 132
  • [17] The effect of luseogliflozin on bone microarchitecture in older patients with type 2 diabetes: study protocol for a randomized controlled pilot trial using second-generation, high-resolution, peripheral quantitative computed tomography (HR-pQCT)
    Ai Haraguchi
    Riyoko Shigeno
    Ichiro Horie
    Shimpei Morimoto
    Ayako Ito
    Ko Chiba
    Yurika Kawazoe
    Shigeki Tashiro
    Junya Miyamoto
    Shuntaro Sato
    Hiroshi Yamamoto
    Makoto Osaki
    Atsushi Kawakami
    Norio Abiru
    Trials, 21
  • [18] The effect of luseogliflozin on bone microarchitecture in older patients with type 2 diabetes: study protocol for a randomized controlled pilot trial using second-generation, high-resolution, peripheral quantitative computed tomography (HR-pQCT)
    Haraguchi, Ai
    Shigeno, Riyoko
    Horie, Ichiro
    Morimoto, Shimpei
    Ito, Ayako
    Chiba, Ko
    Kawazoe, Yurika
    Tashiro, Shigeki
    Miyamoto, Junya
    Sato, Shuntaro
    Yamamoto, Hiroshi
    Osaki, Makoto
    Kawakami, Atsushi
    Abiru, Norio
    TRIALS, 2020, 21 (01)