EZ-IO® intraosseous device implementation in German Helicopter Emergency Medical Service

被引:38
|
作者
Helm, Matthias [1 ]
Haunstein, Benedikt [1 ]
Schlechtriemen, Thomas [3 ]
Ruppert, Matthias [2 ]
Lampl, Lorenz [1 ]
Gaessler, Michael [2 ]
机构
[1] Armed Forces Med Ctr Ulm, Dept Anaesthesiol & Intens Care Med, Sect Emergency Med HEMS Christoph 22, D-8970 Ulm, Germany
[2] ADAC Luftrettung, Dept Med, Munich, Germany
[3] ADAC Luftrettung, Med Qual Management, Munich, Germany
关键词
Emergency medicine; EZ-IO (R); Helicopter Emergency Medical Service; Intraosseous vascular access; Vascular access; ACCESS; INFUSION;
D O I
10.1016/j.resuscitation.2014.12.015
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Intraosseous access (IO) is a rapid and safe alternative when peripheral venous access is difficult. Our aim was to summarize the first three years experience with the use of a semi-automatic IO device (EZ-IO (R)) in German Helicopter Emergency Medical Service (HEMS). Methods: Included were all patients during study period (January 2009-December 2011) requiring an IO access performed by HEMS team. Outcome variables were IO rate, IO insertion success rates, site of IO access, type of EZ-IO (R) needle set used, strategy of vascular access, procedure related problems and operator's satisfaction. Results: IO rate was 0.3% (348/120.923). Overall success rate was 99.6% with a first attempt success rate of 85.9%; there was only one failure (0.4%). There were three insertion sites: proximal tibia (87.2%), distal tibia (7.5%) and proximal humerus (5.3%). Within total study group IO was predominantly the second-line strategy (39% vs. 61%, p < 0.001), but in children < 7 years, in trauma cases and in cardiac arrest IO was more often first-line strategy (64% vs. 28%, p < 0.001; 48% vs. 34%, p < 0.032; 50% vs. 29%, p < 0.002 respectively). Patients with IO access were significantly younger (41.7 +/- 28.7 vs. 56.5 +/- 24.4 years; p < 0.001), more often male (63.2% vs. 57.7%; p = 0.037), included more trauma cases (37.3% vs. 30.0%; p = 0.003) and more often patients with a NACA-Score >= 5 rating (77.0% vs. 18.6%; p < 0.001). Patients who required IO access generally presented with more severely compromised vital signs associated with the need for more invasive resuscitation actions such as intubation, chest drains, CPR and defibrillation. In 93% EZ-IO (R) needle set handling was rated "good". Problems were reported in 1.6% (needle dislocation 0.8%, needle bending 0.4% and parafusion 0.4%). Conclusions: The IO route was generally used in the most critically ill of patients. Our relatively low rate of usage would indicate that this would be compatible with the recommendations of established guidelines. The EZ-IO (R) intraosseous device proved feasible with a high success rate in adult and pediatric emergency patients in HEMS. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:43 / 47
页数:5
相关论文
共 50 条
  • [21] NON-COMPARATIVE STUDY TO EVALUATE INTRAOSSEOUS CATHETER INSERTION WITH THE EZ-IO G3 DEVICE BY NOVICE PARTICIPANTS IN A FELINE CADAVER MODEL
    Leis, M. L.
    Snead, E. C. R.
    Dhumeaux, M. P.
    Epp, T. Y.
    Carr, A. P.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2011, 25 (03) : 738 - 738
  • [22] EZ-IO in the ED: an observational, prospective study comparing flow rates with proximal and distal tibia intraosseous access in adults
    Tan, Boon Kiat Kenneth
    Chong, Stephanie
    Koh, Zhi Xiong
    Ong, Marcus Eng Hock
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2012, 30 (08): : 1602 - 1606
  • [23] Paramedics successfully perform humeral EZ-IO intraosseous access in adult out-of-hospital cardiac arrest patients
    Wampler, David
    Schwartz, Daniel
    Shumaker, Joi
    Bolleter, Scotty
    Beckett, Robert
    Manifold, Craig
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2012, 30 (07): : 1095 - 1099
  • [24] Complete Neurological Recovery After Emergency Burr Hole Placement Utilizing EZ-IO® for Epidural Hematoma
    Grossman, Marc
    See, Alfred P.
    Mannix, Rebekya
    Simon, Erin L.
    JOURNAL OF EMERGENCY MEDICINE, 2022, 63 (04): : 557 - 560
  • [25] Helicopter emergency medical service
    Skogvoll, E
    Rygnestad, T
    LANCET, 1996, 348 (9026): : 543 - 543
  • [26] Comparison of NIO and EZ-IO intraosseous access devices in adult patients under resuscitation performed by paramedics: a randomized crossover manikin trial
    Szarpak, Lukasz
    Czyzewski, Lukasz
    Woloszczuk-Gebicka, Bogumila
    Krajewski, Pawel
    Fudalej, Marcin
    Truszewski, Zenon
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (06): : 1166 - 1167
  • [27] Comparison of helicopter and ground Emergency Medical Service: A retrospective analysis of a German rescue helicopter base
    Mommsen, Philipp
    Bradt, Nikolas
    Zeckey, Christian
    Andruszkow, Hagen
    Petri, Max
    Frink, Michael
    Hildebrand, Frank
    Krettek, Christian
    Probst, Christian
    TECHNOLOGY AND HEALTH CARE, 2012, 20 (01) : 49 - 56
  • [28] Helicopter emergency medical service - Reply
    Hotvedt, R
    LANCET, 1996, 348 (9026): : 544 - 544
  • [29] HELICOPTER EMERGENCY MEDICAL-SERVICE
    WILLIAMS, DL
    JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 1994, 87 (04) : 248 - 248
  • [30] Helicopter emergency medical service safety
    Levick, Nadine
    ANNALS OF EMERGENCY MEDICINE, 2006, 48 (05) : 635 - 636