EZ-IO® intraosseous device implementation in German Helicopter Emergency Medical Service

被引:38
|
作者
Helm, Matthias [1 ]
Haunstein, Benedikt [1 ]
Schlechtriemen, Thomas [3 ]
Ruppert, Matthias [2 ]
Lampl, Lorenz [1 ]
Gaessler, Michael [2 ]
机构
[1] Armed Forces Med Ctr Ulm, Dept Anaesthesiol & Intens Care Med, Sect Emergency Med HEMS Christoph 22, D-8970 Ulm, Germany
[2] ADAC Luftrettung, Dept Med, Munich, Germany
[3] ADAC Luftrettung, Med Qual Management, Munich, Germany
关键词
Emergency medicine; EZ-IO (R); Helicopter Emergency Medical Service; Intraosseous vascular access; Vascular access; ACCESS; INFUSION;
D O I
10.1016/j.resuscitation.2014.12.015
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Intraosseous access (IO) is a rapid and safe alternative when peripheral venous access is difficult. Our aim was to summarize the first three years experience with the use of a semi-automatic IO device (EZ-IO (R)) in German Helicopter Emergency Medical Service (HEMS). Methods: Included were all patients during study period (January 2009-December 2011) requiring an IO access performed by HEMS team. Outcome variables were IO rate, IO insertion success rates, site of IO access, type of EZ-IO (R) needle set used, strategy of vascular access, procedure related problems and operator's satisfaction. Results: IO rate was 0.3% (348/120.923). Overall success rate was 99.6% with a first attempt success rate of 85.9%; there was only one failure (0.4%). There were three insertion sites: proximal tibia (87.2%), distal tibia (7.5%) and proximal humerus (5.3%). Within total study group IO was predominantly the second-line strategy (39% vs. 61%, p < 0.001), but in children < 7 years, in trauma cases and in cardiac arrest IO was more often first-line strategy (64% vs. 28%, p < 0.001; 48% vs. 34%, p < 0.032; 50% vs. 29%, p < 0.002 respectively). Patients with IO access were significantly younger (41.7 +/- 28.7 vs. 56.5 +/- 24.4 years; p < 0.001), more often male (63.2% vs. 57.7%; p = 0.037), included more trauma cases (37.3% vs. 30.0%; p = 0.003) and more often patients with a NACA-Score >= 5 rating (77.0% vs. 18.6%; p < 0.001). Patients who required IO access generally presented with more severely compromised vital signs associated with the need for more invasive resuscitation actions such as intubation, chest drains, CPR and defibrillation. In 93% EZ-IO (R) needle set handling was rated "good". Problems were reported in 1.6% (needle dislocation 0.8%, needle bending 0.4% and parafusion 0.4%). Conclusions: The IO route was generally used in the most critically ill of patients. Our relatively low rate of usage would indicate that this would be compatible with the recommendations of established guidelines. The EZ-IO (R) intraosseous device proved feasible with a high success rate in adult and pediatric emergency patients in HEMS. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
下载
收藏
页码:43 / 47
页数:5
相关论文
共 50 条
  • [1] INTRAOSSEOUS ACCESS EZ-IO IN A PREHOSPITAL EMERGENCY SERVICE
    Torres, Francisco
    Dolores Galan, Maria
    del Mar Alonso, Maria
    Suarez, Rosa
    Camacho, Carmen
    Almagro, Veronica
    JOURNAL OF EMERGENCY NURSING, 2013, 39 (05) : 511 - 514
  • [2] EZ-IO® intraosseous device implementation in a pre-hospital emergency service: A prospective study and review of the literature
    Santos, David
    Carron, Pierre-Nicolas
    Yersin, Bertrand
    Pasquier, Mathieu
    RESUSCITATION, 2013, 84 (04) : 440 - 445
  • [3] Semi-automatic intraosseous device (EZ-IO) in a paediatric emergency department
    Mori, Takaaki
    Takei, Hirokazu
    Sasaoka, Yuta
    Nomura, Osamu
    Ihare, Takateru
    JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2020, 56 (09) : 1376 - 1381
  • [4] Powered intraosseous device (EZ-IO) for critically ill patients
    Oksan, Derinoz
    Ayfer, Keles
    INDIAN PEDIATRICS, 2013, 50 (07) : 689 - 691
  • [5] A multijurisdictional experience with the EZ-IO intraosseous device in the prehospital setting
    Byars, Donald V.
    Tsuchitani, Sara N.
    Yates, Jeff
    Knapp, Barry
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (12): : 1712 - 1713
  • [6] Powered intraosseous device (EZ-IO) for critically ill patients
    Derinoz Oksan
    Keles Ayfer
    Indian Pediatrics, 2013, 50 : 689 - 691
  • [7] Intraosseous vascular access in adults using the EZ-IO in an emergency department
    Ngo A.S.-Y.
    Oh J.J.
    Chen Y.
    Yong D.
    Ong M.E.H.
    International Journal of Emergency Medicine, 2009, 2 (3) : 155 - 160
  • [8] Out-of-hospital placement of adult intraosseous assess using the EZ-IO device
    Harrington, L. L.
    Rehbolz, C.
    Mitchell, P. M.
    Dyer, K. S.
    King, K.
    Moyer, P.
    ANNALS OF EMERGENCY MEDICINE, 2007, 50 (03) : S81 - S82
  • [9] Use of the Pediatric EZ-IO Needle by Emergency Medical Services Providers
    Frascone, Ralph J.
    Jensen, Joe
    Rewerka, Sandi S.
    Salzman, Joshua G.
    PEDIATRIC EMERGENCY CARE, 2009, 25 (05) : 329 - 332
  • [10] Efficacy and safety of the EZ-IO™ intraosseous device: Out-of-hospital implementation of a management algorithm for difficult vascular access
    Gazin, Nicolas
    Auger, Harold
    Jabre, Patricia
    Jaulin, Christine
    Lecarpentier, Eric
    Bertrand, Catherine
    Margenet, Alain
    Combes, Xavier
    RESUSCITATION, 2011, 82 (01) : 126 - 129