Breath-hold fast recovery fast spin echo versus conventional non-breath-hold fast spin echo T2-weighted MR imaging of focal liver lesions

被引:0
|
作者
Tseng, GY
Thng, CH
Wong, EH
Tan, AGS
Suman, P
Quek, ST
Ho, JTS
Khoo, JKB
Ooi, LLPJ
Chow, PKH
Chung, YFA
Teh, CSC
机构
[1] Singapore Gen Hosp, Dept Diagnost Radiol, Singapore 169608, Singapore
[2] Singapore Gen Hosp, Dept Gen Surg, Singapore, Singapore
关键词
comparative studies; liver neoplasm; pulse sequences; receiver operating characteristic curve;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: We compare the breath-hold fast recovery fast spin echo (BHFRFSE) T2-weighted and non-breath-hold fast spin echo (NBHFSE) T2-weighted sequences in image quality and lesion characterisation of focal liver lesions. Materials and Methods: Fat-suppressed T2-weighted magnetic resonance (MR) images obtained with the 2 sequences (BHFRFSE and NBHFSE) in 79 patients with 113 liver lesions were analysed retrospectively. The image quality and nature of the lesions were evaluated by 2 experienced radiologists. Results: Based on receiver operating characteristic curve analysis, lesion characterisation was comparable for both sequences. The image quality of BHFRFSE was significantly better than that of NBHFSE. The NBHFSE missed 4 malignant lesions while BHFRFSE missed 2 malignant lesions. Conclusion: BHFRFSE performs similarly to NBHFSE in image quality and liver lesion characterisation.
引用
收藏
页码:450 / 454
页数:5
相关论文
共 50 条
  • [41] Detection and characterization of focal hepatic lesions by T2-weighted imaging: comparison of navigator-triggered turbo spin-echo, breath-hold turbo spin-echo, and HASTE sequences
    Lee, Ho Yun
    Lee, Jeong Min
    Kim, Se Hyung
    Shin, Kyung Sook
    Lee, Jae Young
    Han, Joon Koo
    Choi, Byung Ihn
    CLINICAL IMAGING, 2009, 33 (04) : 281 - 288
  • [42] T2-weighted MR imaging of the uterus: Comparison of optimized fast spin-echo and HASTE sequences with conventional fast spin-echo sequences
    Gryspeerdt, S
    Van Hoe, L
    Bosmans, H
    Baert, AL
    Vergote, I
    Marchal, G
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 211 - 215
  • [43] Fast-recovery fast spin-echo T2-weighted MR imaging: a free-breathing alternative to fast spin-echo in the pediatric abdomen
    I-Hua Huang
    Kathleen H. Emery
    Tal Laor
    Mona Valentine
    Jan Tiefermann
    Pediatric Radiology, 2008, 38 : 675 - 679
  • [44] Fast-recovery fast spin-echo T2-weighted MR imaging: a free-breathing alternative to fast spin-echo in the pediatric abdomen
    Huang, I-Hua
    Emery, Kathleen H.
    Laor, Tal
    Valentine, Mona
    Tiefermann, Jan
    PEDIATRIC RADIOLOGY, 2008, 38 (06) : 675 - 679
  • [45] T2-WEIGHTED MR-IMAGING OF THE ABDOMEN - FAST SPIN-ECHO VS CONVENTIONAL SPIN-ECHO SEQUENCES
    CATASCA, JV
    MIROWITZ, SA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 61 - 67
  • [46] COMPARISON OF RESPIRATORY-TRIGGERED T2-WEIGHTED TURBO SPIN-ECHO IMAGING VERSUS BREATH-HOLD T2-WEIGHTED TURBO SPIN-ECHO IMAGING: DISTINGUISHING BENIGN FROM MALIGNANT LIVER LESIONS IN PATIENTS WITH COLORECTAL CANCER
    Coenegrachts, K.
    ter Beek, L.
    Haspeslagh, M.
    Bipat, S.
    Stoker, J.
    Rigauts, H.
    JBR-BTR, 2009, 92 (04): : 195 - 201
  • [47] Fast breath-hold T2-weighted MRI of the kidney by means of half-Fourier single-shot turbo spin echo: Comparison with high resolution turbo spin echo sequence
    Nakayama, Y
    Yamashita, Y
    Matsuno, Y
    Tang, Y
    Namimoto, T
    Kadota, M
    Mitsuzaki, K
    Abe, Y
    Katahira, K
    Arakawa, A
    Takahashi, M
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (01) : 55 - 60
  • [48] Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering
    Biederer, J
    Reuter, M
    Both, M
    Muhle, C
    Grimm, J
    Graessner, J
    Heller, M
    EUROPEAN RADIOLOGY, 2002, 12 (02) : 378 - 384
  • [49] Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering
    J. Biederer
    M. Reuter
    M. Both
    C. Muhle
    J. Grimm
    J. Graessner
    M. Heller
    European Radiology, 2002, 12 : 378 - 384
  • [50] Breath-hold black blood quantitative T1rho imaging of liver using single shot fast spin echo acquisition
    Chen, Weitian
    Chan, Queenie
    Wang, Yi-Xiang J.
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2016, 6 (02) : 168 - 177