Effect of pulp chamber depth on the accuracy of endocrown scans made with different intraoral scanners versus an industrial scanner: An in vitro study

被引:18
|
作者
Gurpinar, Bahar [1 ]
Tak, Onjen [1 ]
机构
[1] Okan Univ, Fac Dent, Dept Prosthodont, TR-34497 Istanbul, Turkey
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2022年 / 127卷 / 03期
关键词
IMPRESSIONS; PRECISION; RESTORATIONS; TRUENESS;
D O I
10.1016/j.prosdent.2020.08.034
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The accuracy of intraoral scanners (IOSs) has been evaluated. However, testing their performance when scanning deep endocrown preparations is lacking. Purpose. The purpose of this in vitro study was to assess the effect of pulpal chamber extension depth (PCED) on scanning accuracy and to compare the accuracy of different IOSs on scanning different PCEDs. Material and methods. Six different IOSs were compared: TRIOS 3, CEREC Omnicam, CEREC Primescan, Planmeca Emerald, iTero Element2, and Virtuo Vivo. Endocrown preparations were digitally designed with a computer-aided design and computer-aided manufacturing (CAD-CAM) software program (Rhicoceros), and the PCEDs of preparations were 2, 3.5, and 5 mm. Designed preparations were milled from a polymethylmethacrylate block (Telio CAD) with a milling unit. Reference scans were obtained from an industrial scanner (ATOS), and 5 test scans of each cavity were made with 6 IOSs. All scans were converted into standard tessellation language (STL) files. The data sets obtained from the IOSs were superimposed on the reference scan to evaluate trueness and on each other within groups to determine precision by using a 3D analysis software program (Geomagic Control X). Obtained data were analyzed with 1-way ANOVA and Tukey HSD tests (alpha=.05). Results. CEREC Primescan was found to have the best trueness and precision among the evaluated IOSs (P<.05), while Planmeca Emerald was found to have the lowest trueness (P<.05). For all tested PCEDs, statistically significant differences were found among IOSs. A PCED with a 2-mm depth (18.57 +/- 4.80 mu m) showed significantly better scanning trueness than that with a 5-mm depth (23.81 +/- 6.53), while no significant differences were found between 2 and 3.5 mm (P>.05). Conclusions: Deep pulpal chamber extensions of endocrown restorations could negatively affect scanning accuracy, and scanning accuracy varies depending on the selected IOS. CEREC Primescan appears to be the best IOS choice for scanning endocrowns with deep pulpal chamber extensions.
引用
收藏
页码:430 / 437
页数:8
相关论文
共 29 条
  • [21] Accuracy of 3D Printed and Digital Casts Produced from Intraoral and Extraoral Scanners with Different Scanning Technologies: In Vitro Study
    Ellakany, Passent
    Aly, Nourhan M.
    Al-Harbi, Fahad
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (06): : 521 - 528
  • [22] Scan accuracy and time efficiency of different implantsupported fixed partial denture situations depending on the intraoral scanner and scanned area: An in vitro study
    Donmez, Mustafa Borga
    Mathey, Ayse
    Gaumann, Fabio
    Mathey, Amber
    Yilmaz, Burak
    Abou-Ayash, Samir
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06): : 1198 - 1207
  • [23] Comparison of Different Intraoral Scanners With Prefabricated Aid on Accuracy and Framework Passive Fit of Digital Complete-Arch Implant Impression: An In Vitro Study
    Fu, Xiao-Jiao
    Liu, Min
    Shi, Jun-Yu
    Deng, Ke
    Lai, Hong-Chang
    Gu, Wen
    Zhang, Xiao-Meng
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2024,
  • [24] Effect of auxiliary geometric devices on the accuracy of intraoral scans in full-arch implant-supported rehabilitations: An in vitro study
    Canullo, Luigi
    Pesce, Paolo
    Caponio, Vito Carlo Alberto
    Iacono, Roberta
    Raffone, Carlo
    Luciani, Francesco Saverio
    Menini, Maria
    [J]. JOURNAL OF DENTISTRY, 2024, 145
  • [25] Effect of splinting scan bodies on trueness of complete-arch implant impression using different intraoral scanners: an in vitro study
    Retana, Luciano
    Nejat, Amir H.
    Pozzi, Alessandro
    [J]. INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2023, 26 (01) : 19 - 28
  • [26] Effect of Scanner Type and Scan Body Location on the Accuracy of Mandibular Complete-Arch Digital Implant Scans: An In Vitro Study
    Cakmak, Gulce
    Yilmaz, Hakan
    Santos, Alejandro Trevino
    Kokat, Ali Murat
    Yilmaz, Burak
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (05): : 419 - 426
  • [27] The Influence of Laboratory Scanner versus Intra-Oral Scanner on Determining Axes and Distances between Three Implants in a Straight Line by Using Two Different Intraoral Scan Bodies: A Pilot In Vitro Study
    Shely, Asaf
    Lugassy, Diva
    Rosner, Ophir
    Zanziper, Eran
    Nissan, Joseph
    Rachmiel, Shir
    Khoury, Yara
    Ben-Izhack, Gil
    [J]. JOURNAL OF CLINICAL MEDICINE, 2023, 12 (20)
  • [28] Effect of Scanning Origin Location on Data Accuracy of Abutment Teeth Region in Digital Impression Acquired Using Intraoral Scanner for Removable Partial Denture: A Preliminary In Vitro Study
    Kim, Eung-Yeol
    Wada, Junichiro
    Sakamoto, Kazuki
    Ishioka, Yurika
    Arai, Yuki
    Murakami, Natsuko
    Yamazaki, Toshiki
    Hayama, Hironari
    Utsumi, Miona
    Inukai, Shusuke
    Wakabayashi, Noriyuki
    [J]. JOURNAL OF CLINICAL MEDICINE, 2022, 11 (24)
  • [29] Effect of different impression coping and scan body designs on the accuracy of conventional versus digital implant impressions: An in vitro study
    Alkindi, Shaikha
    Hamdoon, Zaid
    Aziz, Ahmed M.
    [J]. JOURNAL OF DENTISTRY, 2024, 146