Back-EMF based detection of stator winding inter-turn fault for PM synchronous motor drives

被引:18
|
作者
Boileau, T. [1 ]
Nahid-Mobarakeh, B. [1 ]
Meibody-Tabar, F. [1 ]
机构
[1] ENSEM INPL, CNRS, UMR 7037, GREEN, F-54516 Vandoeuvre Les Nancy, France
来源
2007 IEEE VEHICLE POWER AND PROPULSION CONFERENCE, VOLS 1 AND 2 | 2007年
关键词
fault diagnosis; inter-turn fault; PMSM; health monitoring;
D O I
10.1109/VPPC.2007.4544105
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a new technique for stator winding inter-turn fault detection in Permanent Magnet Synchronous Machines is proposed. It consists of extracting the mechanical power second harmonic component which appears when the machine is faulty. This harmonic is processed in order to obtain a fault indicator. It will be shown that the amplitude of this indicator depends on the inter-turn fault severity. The proposed technique allows detecting the fault in real time and its implementation is easy. The experimental results show the validity of the proposed method.
引用
收藏
页码:95 / 100
页数:6
相关论文
共 50 条
  • [21] Field Winding Inter-Turn Fault Detection in Round Rotor Synchronous Machines
    Andere, M. E.
    Rocha E, J. J.
    Bortoni, E. C.
    2015 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2015,
  • [22] FEM Simulation and Analysis on Stator Winding Inter-turn Fault in DFIG
    Chen, Yu
    Wang, Lulu
    Wang, Zihao
    Rehman, Attiq Ur
    Cheng, Yonghong
    Zhao, Yong
    Tanaka, Toshikatsu
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 244 - 247
  • [23] Modeling of IM with Stator Winding Inter-turn Fault Validated by FEM
    Vaseghi, B.
    Takorabet, N.
    Meibody-Tabar, F.
    ICEM: 2008 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES, VOLS 1- 4, 2009, : 1695 - 1699
  • [24] Speed and position estimation for PM synchronous motor with back-EMF observer
    Tursini, M
    Petrella, R
    Scafati, A
    CONFERENCE RECORD OF THE 2005 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2005, : 2083 - 2090
  • [25] Detection of Stator Winding Inter-Turn Short Circuit Fault in Induction Motor Using Vibration Signals by MEMS Accelerometer
    Hegde, Vishwanath
    Rao, Maruthi Gujjar Sathyanarayana
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2017, 45 (13) : 1463 - 1473
  • [26] A Fault Location Method of Stator Winding Inter-turn Short Circuit for Synchronous Condenser Based on Phase Angle Difference
    Wang W.
    Huang S.
    Wang X.
    Wei C.
    Cheng M.
    Deng F.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (18): : 7268 - 7276
  • [27] Stator winding inter-turn insulation fault detection in induction motors by symmetrical components method
    Ballal, M. S.
    Suryawanshi, H. M.
    Mishra, Mahesh K.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2008, 36 (07) : 741 - 753
  • [28] Stator Inter-turn Fault Modelling and Analysis on Induction Motor based on MCCM
    Babu, Akash C.
    Seshadrinath, Jeevanand
    2021 INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND FUTURE ELECTRIC TRANSPORTATION (SEFET), 2021,
  • [29] Novel detection method of stator winding inter-turn short circuit fault in induction motors
    School of Electrical and Electronic Engineering, North China Electric Power University, Baoding 071003, China
    不详
    Zhongguo Dianji Gongcheng Xuebao, 2008, 21 (73-79):
  • [30] Stator End-Winding Thermal and Magnetic Sensor Arrays for Online Stator Inter-Turn Fault Detection
    Kumar, Padmanabhan Sampath
    Xie, Lihua
    Halick, Mohamed Sathik Mohamed
    Vaiyapuri, Viswanathan
    IEEE SENSORS JOURNAL, 2021, 21 (04) : 5312 - 5321