Digital Laser Doppler Flowmetry: Device, Signal Processing Technique, and Clinical Testing

被引:4
|
作者
Kozlov, I. O. [1 ]
Zherebtsov, E. A. [1 ]
Podmasteryev, K., V [1 ]
Dunaev, A., V [1 ]
机构
[1] Orel State Univ, Oryol, Russia
来源
基金
俄罗斯基础研究基金会;
关键词
OSCILLATIONS;
D O I
10.1007/s10527-021-10061-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A method and a device for digital laser Doppler flowmetry are proposed. An approach to signal processing based on analysis of the power spectrum amplitude distribution over Doppler broadening frequencies is suggested. A prototype of the device is presented; its technical characteristics and settings used in tests are described. The method was tested in healthy volunteers of different ages and patients with type 2 diabetes mellitus. The research led to the development of binary classifiers for classifying volunteers and patients into groups according to the functional state of microcirculation.
引用
收藏
页码:12 / 16
页数:5
相关论文
共 50 条
  • [21] NEW METHDOD OF LASER DOPPLER FLOWMETRY SIGNAL PROCESSING IN PULP VITALITY EVALUATION AFTER TEETH COSMETIC TREATMENT
    Todea, Carmen
    Amalia, Sarpe
    Bogdan, Vitez
    Gheorghe, Draganescu
    FIFTH INTERNATIONAL CONFERENCE ON LASERS IN MEDICINE: BIOTECHNOLOGIES INTEGRATED IN DAILY MEDICINE, 2014, 8925
  • [22] RELIABILITY OF LASER-DOPPLER FLOWMETRY IN TESTING AUTOTRANSPLANTED MATURE TEETH
    MENSDORFFPOUILLY, N
    HAAS, R
    MALLATH, G
    WATZEK, G
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 464 - 464
  • [23] RELIABILITY OF LASER-DOPPLER FLOWMETRY IN TESTING VITALITY OF HUMAN TEETH
    INGOLFSSON, AR
    TRONSTAD, L
    RIVA, CE
    ENDODONTICS & DENTAL TRAUMATOLOGY, 1994, 10 (04): : 185 - 187
  • [24] Laser Doppler flowmetry: Characteristics of a modified single-fibre technique
    Cai, H.
    Rohman, H.
    Larsson, S.E.
    Öberg, P.A.
    Medical and Biological Engineering and Computing, 1996, 34 (01): : 2 - 8
  • [25] ASSESSING VULVAR LESIONS - LASER-DOPPLER FLOWMETRY AS A POSSIBLE TECHNIQUE
    JACKSON, AE
    OSBORNE, MJ
    SEIFALIAN, A
    MACLEAN, AB
    JOURNAL OF REPRODUCTIVE MEDICINE, 1994, 39 (12) : 953 - 956
  • [26] Laser Doppler flowmetry: Characteristics of a modified single-fibre technique
    Cai, H
    Rohman, H
    Larsson, SE
    Oberg, PA
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1996, 34 (01) : 2 - 8
  • [27] Signal processing methodology to study the cutaneous vasodilator response to a local external pressure application detected by laser Doppler flowmetry
    Humeau, A
    Fizanne, L
    Garry, A
    Saumet, JL
    L'Huillier, JP
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (01) : 190 - 192
  • [28] Pulsed laser Doppler flowmetry for increased signal to noise ratio and probed depth
    Steenbergen, W
    Kolkman, R
    Woldberg, S
    de Mul, F
    OPTICAL DIAGNOSTICS AND SENSING IN BIOMEDICINE III, 2003, 4965 : 49 - 54
  • [29] Laser Doppler flowmetry in healthy rats: impact of isoflurane anesthetic on signal complexity
    Humeau, Anne
    Haussy, Bernard
    Fizanne, Lionel
    Roux, Jerome
    Asfar, Pierre
    Cales, Paul
    Rousseau, David
    Chapeau-Blondeau, Francois
    2008 MEDITERRANEAN CONFERENCE ON CONTROL AUTOMATION, VOLS 1-4, 2008, : 298 - +
  • [30] DOPPLER SIGNAL-PROCESSING - NEW TECHNIQUE
    CASASENT, D
    PSALTIS, D
    APPLIED OPTICS, 1976, 15 (09) : 2015 - 2015