Clinical and radiological outcome at 10 years of follow-up after total cervical disc replacement

被引:62
|
作者
Mehren, Christoph [1 ,2 ,3 ]
Heider, Franziska [1 ,2 ,3 ]
Siepe, Christoph J. [1 ,2 ,3 ]
Zillner, Bernhard [1 ,2 ,3 ]
Kothe, Ralph [4 ,5 ]
Korge, Andreas [1 ,2 ,3 ]
Mayer, H. Michael [1 ,2 ,3 ]
机构
[1] Schon Klin Munchen Harlaching, Spine Ctr, Harlachinger Str 51, D-81547 Munich, Germany
[2] Paracelsus Private Med Univ Salzburg, Acad Teaching Hosp, Salzburg, Austria
[3] Paracelsus Private Med Univ Salzburg, Spine Res Inst, Salzburg, Austria
[4] Schon Klin Eilbeck, Clin Spinal Surg, Hamburg, Germany
[5] Univ Med Ctr Hamburg Eppendorf, Dept Orthoped, Hamburg, Germany
关键词
Total cervical disc replacement; Prodisc C; Long-term follow-up; Heterotopic ossification; Adjacent segment disease; ARTIFICIAL DISC; HETEROTOPIC OSSIFICATION; RADIOGRAPHIC OUTCOMES; ANTERIOR DISKECTOMY; FUSION; ARTHROPLASTY; ARTICLE; TRIAL; ADJACENT; PROSTHESIS;
D O I
10.1007/s00586-017-5204-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Previous studies have demonstrated that total cervical disc replacement (cTDR) represents a viable treatment alternative to the 'gold standard' anterior cervical discectomy and fusion for the treatment of well-defined cervical pathologies at short- and mid-term follow-up (FU). However, the implementation and acceptance of a non-fusion philosophy is closely associated with its avoidance of adjacent segment degeneration. Proof of the functional sustainability and clinical improvement of symptoms at long-term FU is still pending. The aim of this ongoing prospective study was to investigate the clinical and radiological results of cTDR at long-term FU. 50 patients were treated surgically within a non-randomised prospective study framework with cTDR (ProDisc C (TM), Synthes, Paoli, PA, USA). Patients were examined preoperatively followed by routine clinical and radiological examinations at 1, 5 and 10 years after surgery, respectively. In addition to the clinical scores, conventional X-ray images of the cervical spine were taken in anteroposterior and lateral view as well as flexion/extension images. Clinical outcome scores included parameters such as the Neck Disability Index (NDI), Visual Analogue Scale (VAS), arm and neck pain self-assessment questionnaires as well as subjective patient satisfaction rates. The radiological outcome variables included the range of motion (ROM) of the implanted prosthesis between maximum flexion and extension images, the occurrence of heterotopic ossifications and radiographic signs of adjacent segment degenerative changes. The reoperation rate following cTDR was recorded as a secondary outcome variable. A significant and maintained clinical improvement of all clinical outcome scores was observed after a mean FU of 10.2 years (VASarm 6.3-2.1; VASneck 6.4-1.9; NDI 21-6; p < 0.05). An increase in the incidence and the extent of heterotopic ossifications was noted during the post-operative course with a significant influence on the function of the prosthesis, which, however, did not reveal any detrimental effect on the patients' clinical symptomatology. Prosthesis mobility declined from 9.0A degrees preoperatively and 9.1A degrees at 1 year FU to 7.7A degrees and 7.6A degrees at the five- and ten-year FU examinations, respectively. Radiological signs of adjacent segment degeneration were detected in 13/38 (35.7%), however, in only 3/38 (7.9%) patients this radiological changes were associated with clinical symptoms requiring conservative treatment. Intraoperative technical failure in two cases required interbody fusion with a cage (2/50). One patient (1/48, 2.1%) treated this motion device had revision surgery at the index level. Cervical total disc replacement with ProDisc C demonstrated a significant and maintained improvement of all clinical outcome parameters at a follow-up of 10 years. The present long-term data reveal that with an exceptionally low implant-related reoperation rate and low symptomatic adjacent segment degeneration rate, cTDR may be regarded as a safe and viable treatment option.
引用
收藏
页码:2441 / 2449
页数:9
相关论文
共 50 条
  • [21] Clinical and radiological outcomes of cervical disc arthroplasty: ten year follow-up study
    Song, Qingpeng
    He, Da
    Han, Xiao
    Zhang, Ning
    Wang, Jinchao
    Tian, Wei
    [J]. INTERNATIONAL ORTHOPAEDICS, 2018, 42 (10) : 2389 - 2396
  • [22] Eight-Year Clinical and Radiological Follow-Up of the Bryan Cervical Disc Arthroplasty
    Quan, Gerald M. Y.
    Vital, Jean-Marc
    Hansen, Steve
    Pointillart, Vincent
    [J]. SPINE, 2011, 36 (08) : 639 - 646
  • [23] Clinical and radiological outcomes of cervical disc arthroplasty: ten year follow-up study
    Qingpeng Song
    Da He
    Xiao Han
    Ning Zhang
    Jinchao Wang
    Wei Tian
    [J]. International Orthopaedics, 2018, 42 : 2389 - 2396
  • [24] Clinical and radiological outcome 1-year after cervical total disc replacement using the Signus ROTAIO – Prosthesis
    Anna Lang
    Sara Lener
    Lukas Grassner
    Anto Abramovic
    Claudius Thomé
    Dennis Päsler
    Jens Lehmberg
    Ralph Schär
    Sebastian Hartmann
    [J]. European Spine Journal, 2022, 31 : 3477 - 3483
  • [25] Clinical and radiological outcome 1-year after cervical total disc replacement using the Signus ROTAIO - Prosthesis
    Lang, Anna
    Lener, Sara
    Grassner, Lukas
    Abramovic, Anto
    Thome, Claudius
    Paesler, Dennis
    Lehmberg, Jens
    Schaer, Ralph
    Hartmann, Sebastian
    [J]. EUROPEAN SPINE JOURNAL, 2022, 31 (12) : 3477 - 3483
  • [26] Change in cervical range of motion and sagittal alignment in early and late phases after total disc replacement: radiographic follow-up exceeding 2 years Clinical article
    Ahn, Poong-Gi
    Kim, Keung Nyun
    Moon, Sung Whan
    Kim, Keun Su
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2009, 11 (06) : 688 - 695
  • [27] Cervical disc arthroplasty with the Baguera C prosthesis: clinical and radiological results of a 10-year follow-up study
    P. Fransen
    D. Noriega
    A. Chatzisotiriou
    V. Pointillart
    [J]. European Spine Journal, 2023, 32 : 3533 - 3539
  • [28] Cervical disc arthroplasty with the Baguera C prosthesis: clinical and radiological results of a 10-year follow-up study
    Fransen, P.
    Noriega, D.
    Chatzisotiriou, A.
    Pointillart, V.
    [J]. EUROPEAN SPINE JOURNAL, 2023, 32 (10) : 3533 - 3539
  • [29] Intermediate Results of the Prestige LP Cervical Disc Replacement Clinical and Radiological Analysis With Minimum Two-Year Follow-up
    Peng, Chan Wearn Benedict
    Yue, Wai Mun
    Basit, Abdul
    Guo, Chang Ming
    Tow, Benjamin Phak Boon
    Chen, John Li Tat
    Nidu, Maran
    Yeo, William
    Tan, Seang Beng
    [J]. SPINE, 2011, 36 (02) : E105 - E111
  • [30] Clinical results and development of heterotopic ossification in total cervical disc replacement during a 4-year follow-up
    Petr Suchomel
    Lubomír Jurák
    Vladimír Beneš
    Radim Brabec
    Ondřej Bradáč
    Shamel Elgawhary
    [J]. European Spine Journal, 2010, 19 : 307 - 315