Accuracy of Nasal Nitric Oxide Measurement as a Diagnostic Test for Primary Ciliary Dyskinesia A Systematic Review and Meta-analysis

被引:49
|
作者
Shapiro, Adam J. [1 ]
Josephson, Maureen [2 ]
Rosenfeld, Margaret [3 ,4 ]
Yilmaz, Ozge [5 ]
Davis, Stephanie D. [6 ]
Polineni, Deepika [7 ]
Guadagno, Elena [8 ]
Leigh, Margaret W. [9 ]
Lavergne, Valery [10 ]
机构
[1] McGill Univ, Montreal Childrens Hosp, Hlth Ctr, Div Pediat Resp Med,Res Inst, 1001 Blvd Decarie,BRC 5016, Montreal, PQ H4A 3J1, Canada
[2] Univ Penn, Childrens Hosp Philadelphia, Div Pediat Pulmonol, Philadelphia, PA 19104 USA
[3] Univ Washington, Seattle Childrens Hosp, Div Pediat Pulmonol, Seattle, WA 98195 USA
[4] Univ Washington, Reg Med Ctr, Seattle, WA 98195 USA
[5] Celal Bayar Univ, Dept Pediat Allergy & Pulmonol, Fac Med, Manisa, Turkey
[6] Indiana Univ Sch Med, Riley Childrens Hosp, Dept Pediat, Sect Pediat Pulmonol Allergy & Sleep Med, Indianapolis, IN 46202 USA
[7] Univ Kansas, Dept Internal Med, Div Pulm & Crit Care Med, Kansas City, KS USA
[8] McGill Univ, Hlth Ctr, McConnell Resource Ctr, Med Lib, Montreal, PQ, Canada
[9] Univ North Carolina Chapel Hill, Dept Pediat, Div Pediat Pulmonol, Chapel Hill, NC USA
[10] Univ Montreal, Sacre Coeur Hosp, Dept Med Biol, Montreal, PQ, Canada
关键词
primary ciliary dyskinesia; Kartagener syndrome; nitric oxide; CHILDREN; LIKELIHOOD;
D O I
10.1513/AnnalsATS.201701-062SR
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Rationale: Primary ciliary dyskinesia (PCD) is a rare disorder causing chronic otosinopulmonary disease, generally diagnosed through evaluation of respiratory ciliary ultrastructure and/or genetic testing. Nasal nitric oxide (nNO) measurement is used as a PCD screening test because patients with PCD have low nNO levels, but its value as a diagnostic test remains unknown. Objectives: To perform a systematic review to assess the utility of nNO measurement (index test) as a diagnostic tool compared with the reference standard of electron microscopy (EM) evaluation of ciliary defects and/or detection of biallelic mutations in PCD genes. Data Sources: Ten databases were searched for reference sources from database inception through July 29, 2016. Data Extraction: Study inclusion was limited to publications with rigorous nNO index testing, reference standard diagnostic testing with EM and/or genetics, and calculable diagnostic accuracy information for cooperative patients (generally > 5 yr old) with high suspicion of PCD. Synthesis: Meta-analysis provided a summary estimate for sensitivity and specificity and a hierarchical summary receiver operating characteristic curve. The Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess study quality, and Grading of Recommendations Assessment, Development, and Evaluation was used to assess the certainty of evidence. In 12 study populations (1,344 patients comprising 514 with PCD and 830 without PCD), using a reference standard of EM alone or EM and/or genetic testing, summary sensitivity was 97.6% (92.7-99.2) and specificity was 96.0% (87.9-98.7), with a positive likelihood ratio of 24.3 (7.6-76.9), a negative likelihood ratio of 0.03 (0.01-0.08), and a diagnostic odds ratio of 956.8 (141.2-6481.5) for nNO measurements. After studies using EM alone as the reference standard were excluded, the seven studies using an extended reference standard of EM and/or genetic testing showed a summary sensitivity of nNO measurements of 96.3% (88.7-98.9) and specificity of 96.4% (85.1-99.2), with a positive likelihood ratio of 26.5 (5.9-119.1), a negative likelihood ratio of 0.04 (0.01-0.12), and a diagnostic odds ratio of 699.3 (67.4-7256.0). Certainty of the evidence was graded as moderate. Conclusions: nNO is a sensitive and specific test for PCD in cooperative patients (generally > 5 yr old) with high clinical suspicion for this disease. With a moderate level of evidence, this meta-analysis confirms that nNO testing using velum closure maneuvers has diagnostic accuracy similar to EM and/or genetic testing for PCD when cystic fibrosis is ruled out. Thus, low nNO values accompanied by an appropriate clinical phenotype could be used as a diagnostic PCD test, though EM and/or genetics will continue to provide confirmatory information.
引用
收藏
页码:1184 / 1196
页数:13
相关论文
共 50 条
  • [31] Choice of nasal nitric oxide technique as first-line test for primary ciliary dyskinesia
    Marthin, J. K.
    Nielsen, K. G.
    EUROPEAN RESPIRATORY JOURNAL, 2011, 37 (03) : 559 - 565
  • [32] Primary Ciliary Dyskinesia Diagnosis by the Measurement Nasal Nitric Oxide Level in Adults with Bronchiectasis in Ukraine
    Suska, K.
    Gashynova, K.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2022, 205
  • [33] Nasal nitric oxide measurement in children for the diagnosis of primary ciliary dyskinesia: ERS technical standard
    Beydon, N.
    Kouis, P.
    Marthin, J. K.
    Latzin, P.
    Colas, M.
    Davis, S. D.
    Haarman, E.
    Harris, A. L.
    Hogg, C.
    Kilbride, E.
    Kuehni, C. E.
    Marangu, D.
    Nielsen, K. G.
    Pendergrast, C.
    Robinson, P.
    Rumman, N.
    Rutter, M.
    Walker, W. T.
    Ferkol, T.
    Lucas, J. S.
    RESPIROLOGY, 2023, 28 : 205 - 206
  • [34] Nasal Nitric Oxide Measurement in Primary Ciliary Dyskinesia A Technical Paper on Standardized Testing Protocols
    Shapiro, Adam J.
    Dell, Sharon D.
    Gaston, Benjamin
    O'Connor, Michael
    Marozkina, Nadzeya
    Manion, Michele
    Hazucha, Milan J.
    Leigh, Margaret W.
    ANNALS OF THE AMERICAN THORACIC SOCIETY, 2020, 17 (02) : E1 - E12
  • [35] Agenesis of paranasal sinuses and nasal nitric oxide in primary ciliary dyskinesia
    Pifferi, M.
    Bush, A.
    Caramella, D.
    Di Cicco, M.
    Zangani, M.
    Chinellato, I.
    Macchia, P.
    Boner, A. L.
    EUROPEAN RESPIRATORY JOURNAL, 2011, 37 (03) : 566 - 571
  • [36] Nasal nitric oxide for early diagnosis of familial primary ciliary dyskinesia
    Bodini, A.
    Rugolotto, S.
    Pradal, U.
    Zanotto, G.
    Peroni, D.
    ARCHIVES OF DISEASE IN CHILDHOOD, 2008, 93 (05) : 452 - 453
  • [37] Nasal nitric oxide measurements to screen children for primary ciliary dyskinesia
    Corbelli, R
    Bringolf-Isler, B
    Amacher, A
    Sasse, B
    Spycher, M
    Hammer, J
    CHEST, 2004, 126 (04) : 1054 - 1059
  • [38] Toward Standardization Of Nasal Nitric Oxide Testing For Primary Ciliary Dyskinesia
    Baker, B. R.
    Chawla, K. K.
    Hazucha, M.
    Knowles, M. R.
    Leigh, M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183
  • [39] Nasal Versus Tracheobronchial Biopsies to Diagnose Primary Ciliary Dyskinesia: A Meta-Analysis
    Adil, Eelam A.
    Kawai, Kosuke
    Dombrowski, Natasha
    Irace, Alexandria L.
    Cunningham, Michael J.
    LARYNGOSCOPE, 2017, 127 (01): : 6 - 13
  • [40] Diagnostic accuracy of fractional exhaled nitric oxide in asthma: a systematic review and meta-analysis of prospective studies
    Guo, Zhi
    Wang, Ying
    Xing, Guohong
    Wang, Xin
    JOURNAL OF ASTHMA, 2016, 53 (04) : 404 - 412