Real-time fluorescence detection of multiple microscale cell culture analog devices In situ

被引:30
|
作者
Oh, Taek-Il
Sung, Jong Hwan
Tatosian, Daniel A.
Shuler, Michael L.
Kim, Donghyun [1 ]
机构
[1] Yonsei Univ, Sch Elect & Elect Engn, Seoul 120749, South Korea
[2] Cornell Univ, Sch Chem & Biomol Engn, Ithaca, NY 14850 USA
关键词
fluorescence detection; high-throughput screening; microscale cell culture analog; live cell imaging; cell status monitoring; green-fluorescent protein; cell dynamics;
D O I
10.1002/cyto.a.20427
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We investigated multiple microscale cell culture analog (mu CCA) assays in situ with a high-throughput imaging system that provides quantitative, nondestructive, and real-time data on cell viability. Since samples do not move between measurements, captured images allow accurate time-course measurements of cell population response and tracking the fate of each cell type on a quantitative basis. The optical system was evaluated by measuring the short-term response to ethanol exposure and long-term growth of drug-resistant tumor cell lines with simultaneous samples. The optical system based on epi-fluorescent excitation consists of an LED and a CCD as well as discrete optical components for imaging a large number of cells simultaneously. HepG2/C3A and MESSA cell lines were cultured in two mu CCA systems for continuous cell status monitoring in cell death experiments with ethanol and long-term cell growth. The experiment that tested ethanol uptake showed that ethanol immediately caused cell death. The system was applied to extracting dynamic constants in the uptake process. In the long-term cell growth experiment, growth of MESSA cells was followed by a stationary phase and eventual cell death attributed to nutrient and oxygen depletion and a change in the pH because of the accumulation of wastes by cell metabolism. HepG2/C3A cells were sub ject to contact inhibition and cell number did not change significantly over time. Issues related to long-term assays are also discussed. The quantitative results have been consistent with qualitative images and confirm the applicability of the portable optical system, and potential application to high-throughput analysis of cell-based assays to measure long-term dynamics. 0 2007 International Society for Analytical Cytology
引用
收藏
页码:857 / 865
页数:9
相关论文
共 50 条
  • [21] Real-Time Multiple Face Detection and Tracking
    Abin, Ahmad Ali
    Fotouhi, Mehran
    Kasaei, Shohreh
    2009 14TH INTERNATIONAL COMPUTER CONFERENCE, 2009, : 378 - 383
  • [22] Real-Time Binary Cell Phone Usage Detection and Classification on Vehicular Edge Devices
    Onsu, Murat Arda
    Shah, Pankti
    Simsek, Murat
    Fobert, Mark
    Kantarci, Burak
    20TH INTERNATIONAL WIRELESS COMMUNICATIONS & MOBILE COMPUTING CONFERENCE, IWCMC 2024, 2024, : 1100 - 1105
  • [23] Quantitative cell analysis in situ on a short time scale using a microscale cell culture assay
    Oh, Taek-il
    Sung, Jong Hwan
    Tatosian, Daniel A.
    Shuler, Michael L.
    Kim, Donghyun
    2007 PACIFIC RIM CONFERENCE ON LASERS AND ELECTRO-OPTICS, VOLS 1-4, 2007, : 885 - +
  • [24] Reliability odometer for real-time and in situ lifetime measurement of power devices
    Ciappa, Mauro
    Blascovich, Alessandro
    MICROELECTRONICS RELIABILITY, 2015, 55 (9-10) : 1351 - 1356
  • [25] Real-time Multiple Analog Gauges Reader for an Autonomous Robot Application
    Trairattanapa, Visarut
    Phimsiri, Sasin
    Utintu, Chaitat
    Cherdchusakulcha, Riu
    Tosawadi, Teepakorn
    Thamwiwatthana, Ek
    Tungjitnob, Suchat
    Tangamonsiri, Peemapol
    Takutruea, Aphisit
    Keomeesuan, Apirat
    Jitnaknan, Tanapoom
    Suttichaya, Vasin
    2022 17TH INTERNATIONAL JOINT SYMPOSIUM ON ARTIFICIAL INTELLIGENCE AND NATURAL LANGUAGE PROCESSING (ISAI-NLP 2022) / 3RD INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE AND INTERNET OF THINGS (AIOT 2022), 2022,
  • [26] Real-time fluorescence detection of protein transduction into live cells
    Lee, Ya-Jung
    Datta, Silpi
    Pellois, Jean-Philippe
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (08) : 2398 - 2399
  • [27] The detection of HBV DNA by real-time fluorescence quantitative PCR
    Yuan, Y.
    Zhou, X.
    CLINICAL CHEMISTRY, 2008, 54 (06) : A157 - A157
  • [28] Towards fluorescence anisotropy detection for real-time PCR assays
    Crane, B
    Sudo, H
    Thilly, WG
    Hunter, IW
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 3060 - 3063
  • [29] Near real-time beryllium detection based on fluorescence.
    McCleskey, TM
    Burrell, AK
    Ehler, DS
    John, K
    Collis, G
    Minogue, E
    Sauer, NN
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2004, 227 : U96 - U96
  • [30] Real-Time Detection of Formaldehyde by a Fluorescence-Based Sensor
    Descamps, M. N.
    Bordy, T.
    Hue, J.
    Mariano, S.
    Nonglaton, G.
    Schultz, E.
    Tran-Thi, T. H.
    Vignoud-Despond, S.
    EUROSENSORS XXIV CONFERENCE, 2010, 5 : 1009 - 1012