Real-time fluorescence detection of multiple microscale cell culture analog devices In situ

被引:30
|
作者
Oh, Taek-Il
Sung, Jong Hwan
Tatosian, Daniel A.
Shuler, Michael L.
Kim, Donghyun [1 ]
机构
[1] Yonsei Univ, Sch Elect & Elect Engn, Seoul 120749, South Korea
[2] Cornell Univ, Sch Chem & Biomol Engn, Ithaca, NY 14850 USA
关键词
fluorescence detection; high-throughput screening; microscale cell culture analog; live cell imaging; cell status monitoring; green-fluorescent protein; cell dynamics;
D O I
10.1002/cyto.a.20427
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We investigated multiple microscale cell culture analog (mu CCA) assays in situ with a high-throughput imaging system that provides quantitative, nondestructive, and real-time data on cell viability. Since samples do not move between measurements, captured images allow accurate time-course measurements of cell population response and tracking the fate of each cell type on a quantitative basis. The optical system was evaluated by measuring the short-term response to ethanol exposure and long-term growth of drug-resistant tumor cell lines with simultaneous samples. The optical system based on epi-fluorescent excitation consists of an LED and a CCD as well as discrete optical components for imaging a large number of cells simultaneously. HepG2/C3A and MESSA cell lines were cultured in two mu CCA systems for continuous cell status monitoring in cell death experiments with ethanol and long-term cell growth. The experiment that tested ethanol uptake showed that ethanol immediately caused cell death. The system was applied to extracting dynamic constants in the uptake process. In the long-term cell growth experiment, growth of MESSA cells was followed by a stationary phase and eventual cell death attributed to nutrient and oxygen depletion and a change in the pH because of the accumulation of wastes by cell metabolism. HepG2/C3A cells were sub ject to contact inhibition and cell number did not change significantly over time. Issues related to long-term assays are also discussed. The quantitative results have been consistent with qualitative images and confirm the applicability of the portable optical system, and potential application to high-throughput analysis of cell-based assays to measure long-term dynamics. 0 2007 International Society for Analytical Cytology
引用
收藏
页码:857 / 865
页数:9
相关论文
共 50 条
  • [1] Portable real-time fluorescence cytometry of microscale cell culture analog devices
    Kim, Donghyun
    Tatosian, Daniel A.
    Shuler, Michael L.
    IMAGING, MANIPULATION, AND ANALYSIS OF BIOMOLECULES, CELLS, AND TISSUES IV, 2006, 6088
  • [2] Real-time quantitative fluorescence measurement of microscale cell culture analog systems
    Oh, Taek-Il
    Kim, Donghyun
    Tatosian, Daniel
    Sung, Jong Hwan
    Shuler, Michael
    IMAGING, MANIPULATION, AND ANALYSIS OF BIOMOLECULES, CELLS, AND TISSUES V, 2007, 6441
  • [3] Multiple Compact Camera Fluorescence Detector for Real-Time PCR Devices
    Koo, Seul-Bit-Na
    Chi, Hyeon-Gyu
    Kim, Jong-Dae
    Kim, Yu-Seop
    Park, Ji-Sung
    Park, Chan-Young
    Lee, Deuk-Ju
    SENSORS, 2021, 21 (21)
  • [4] In situ visualization and real-time tracking of emulsion and miniemulsion polymerization at the microscale via fluorescence imaging
    Liu, Haotian
    Shi, Jie
    Pu, Yuan
    Wang, Jie-Xin
    Wang, Dan
    Chen, Jian-Feng
    CHEMICAL ENGINEERING SCIENCE, 2020, 211 (211)
  • [5] Fluorescence Optical Detection In Situ for Real-Time Monitoring of Cytochrome P450 Enzymatic Activity of Liver Cells in Multiple Microfluidic Devices
    Sung, Jong Hwan
    Choi, Jong-ryul
    Kim, Donghyun
    Shuler, Michael L.
    BIOTECHNOLOGY AND BIOENGINEERING, 2009, 104 (03) : 516 - 525
  • [6] Real-time fluorescence detection of exoribonucleases
    Sinturel, Flore
    Pellegrini, Olivier
    Xiang, Song
    Tong, Liang
    Condon, Ciaran
    Benard, Lionel
    RNA, 2009, 15 (11) : 2057 - 2062
  • [7] Raman Spectroscopy as a Real-Time In Situ Analyzer for Cell Culture Bioprocesses
    Pitters, Alexander
    Cuellar, Maryann
    Wiegand, Pat
    Gilliam, Sean
    Lewis, Ian R.
    Lenain, Bruno
    NEW BIOTECHNOLOGY, 2016, 33 : S113 - S113
  • [8] Real-time Detection for Multiple Occupancy and Near Real-time Hogging Detection
    Huy, Nguyen Huy Hoang
    Balan, Rajesh Krishna
    Lee, Youngki
    SenSys'15: Proceedings of the 13th ACM Conference on Embedded Networked Sensor Systems, 2015, : 477 - 478
  • [9] Real-time radiology in the microscale
    Hwu, Y
    Je, JH
    Margaritondo, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 551 (01): : 108 - 118
  • [10] Real-time radiology in the microscale
    Hwu, Y
    Je, JH
    Margaritondo, G
    CHINESE JOURNAL OF PHYSICS, 2005, 43 (01) : 285 - 292