Sample-Sample Correlation Asynchronous Spectroscopic Method Coupled with Multivariate Curve Resolution-Alternating Least Squares To Analyze Challenging Bilinear Data

被引:13
|
作者
Guo, Ran [1 ,2 ,3 ]
Zhang, Xin [4 ]
He, An-Gi [3 ]
Yu, Zhen-Qiang [1 ]
Ling, Xiao-Feng [5 ]
Xu, Yi-Zhuang [3 ]
Noda, Isao [3 ,6 ]
Ozaki, Yukihiro [3 ,7 ]
Wu, Jin-Guang [3 ]
机构
[1] Shenzhen Univ, Coll Chem & Environm Engn, Shenzhen 518060, Peoples R China
[2] Shenzhen Univ, Key Lab Optoelect Devices & Syst, Minist Educ & Guangdong Prov, Coll Optoelect Engn, Shenzhen 518060, Peoples R China
[3] Peking Univ, Beijing Natl Lab Mol Sci, State Key Lab Rare Earth Mat Chem & Applicat, Coll Chem & Mol Engn, Beijing 100871, Peoples R China
[4] Capital Normal Univ, Dept Chem, Beijing 100048, Peoples R China
[5] Peking Univ, Sch Clin Med 3, Beijing 100083, Peoples R China
[6] Univ Delaware, Dept Mat Sci & Engn, Newark, DE 19716 USA
[7] Kwansei Gakuin Univ, Dept Chem, Sch Sci & Technol, Sanda, Hyogo 6691337, Japan
基金
中国国家自然科学基金;
关键词
2-DIMENSIONAL CORRELATION SPECTROSCOPY; GEL-PERMEATION CHROMATOGRAPHY; 2D CORRELATION SPECTROSCOPY; PERFORMANCE LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; INFRARED-SPECTRA; DESIGN SCHEME; POLYMERIZATION; ACID; CHEMOMETRICS;
D O I
10.1021/acs.analchem.9b04730
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An approach to construct a secondary asynchronous spectrum via sample sample-correlation (SASS) is proposed to analyze bilinear data from hyphenated spectroscopic experiments. In SASS, bilinear data is used to construct a series of two-dimensional (2D) sample-sample correlation spectra. Then a vertical slice is extracted from each 2D sample-sample correlation spectrum so that a secondary 2D asynchronous spectrum is constructed via these slices. The advantage of SASS is demonstrated by a model system with the following challenging situations: (1) Temporal profiles of different components severely overlap, making spectra of pure components difficult to directly obtain from either original bilinear data or multivariate curve resolution-alternating least squares (MCR-ALS) with non-negativity and unimodality constraints. (2) Every peak in the spectra of the eluted samples contains contributions from at least two components. Hence, two-dimensional correlation spectroscopy (2D-COS) and n-dimensional (nD) asynchronous spectroscopic method developed in our previous work, which previously worked so well, are now invalid. SASS managed to reveal different groups of systematic absences of cross peaks (SACPs) that reflect the lack of spectral contributions of different components at different regions in the second asynchronous spectrum. Spectra of different components can still be faithfully retrieved via MCR-ALS calculation using constraints revealed by different groups of SACPs. The results demonstrate that implicit but intrinsic information revealed by SASS is indispensable in solving challenging bilinear data as the model system. We applied SASS on two real-world examples from thermogravimetry-Fourier transform infrared spectroscopy (TG-FT-IR) experiments of mixtures (H2O/HOD/D2O and H2O/isopropanol/pyridine). FT-IR spectra of different components were successfully recovered. Moreover, FT-IR spectrum of HOD, which is difficult to obtain, was successfully extracted. SASS can be applied in the analysis of gaseous mixtures from TG-FT-IR experiment and a combination of quantum cascade lasers with substrate-integrated hollow waveguides in environmental monitoring and biomedical diagnosis. Furthermore, SASS is also useful in various advanced hyphenated spectroscopic experiments.
引用
收藏
页码:1477 / 1484
页数:8
相关论文
共 50 条
  • [31] Multivariate curve resolution-alternating least squares to study the simultaneous release of Sumatriptan and Naproxen from the polymeric substrate
    Dadashi, Reza
    Bahram, Morteza
    Moghtader, Mehdi
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2020, 17 (04) : 953 - 962
  • [32] Comparison between the direct trilinear decomposition and the multivariate curve resolution-alternating least squares methods for the resolution of three-way data sets
    Dept. de Quim. Analítica, Universitat de Barcelona, Barcelona, Spain
    不详
    不详
    Chemometr. Intell. Lab. Syst., 1 (19-32):
  • [33] Effect of initial estimates and constraints selection in multivariate curve resolution-Alternating least squares. Application to low-resolution NMR data
    Vivo-Truyols, Gabriel
    Ziari, Maya
    Magusin, Pieter C. M. M.
    Schoenmakers, Peter J.
    ANALYTICA CHIMICA ACTA, 2009, 641 (1-2) : 37 - 45
  • [34] Comparison between the direct trilinear decomposition and the multivariate curve resolution-alternating least squares methods for the resolution of three-way data sets
    de Juan, A
    Rutan, SC
    Tauler, R
    Massart, DL
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1998, 40 (01) : 19 - 32
  • [35] Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS) with Raman Imaging Applied to Lunar Meteorites
    Smith, Joseph P.
    Smith, Frank C.
    Booksh, Karl S.
    APPLIED SPECTROSCOPY, 2018, 72 (03) : 404 - 419
  • [36] Evaluation of the Miscibility of Novel Cocoa Butter Equivalents by Raman Mapping and Multivariate Curve Resolution-Alternating Least Squares
    Castro-Alayo, Efrain M.
    Torrejon-Valqui, Llisela
    Cayo-Colca, Ilse S.
    Cardenas-Toro, Fiorella P.
    FOODS, 2021, 10 (12)
  • [37] The effect of constraints on the analytical figures of merit achieved by extended multivariate curve resolution-alternating least-squares
    Pellegrino Vidal, Rocio B.
    Allegrini, Franco
    Olivieri, Alejandro C.
    ANALYTICA CHIMICA ACTA, 2018, 1003 : 10 - 15
  • [38] Quantification of paracetamol through tablet blister packages by Raman spectroscopy and multivariate curve resolution-alternating least squares
    Lyndgaard, Lotte B.
    van den Berg, Frans
    de Juan, Anna
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2013, 125 : 58 - 66
  • [39] Multivariate curve resolution-alternating least squares to study the simultaneous release of Sumatriptan and Naproxen from the polymeric substrate
    Reza Dadashi
    Morteza Bahram
    Mehdi Moghtader
    Journal of the Iranian Chemical Society, 2020, 17 : 953 - 962
  • [40] Coupling of sequential injection chromatography with multivariate curve resolution-alternating least-squares for enhancement of peak capacity
    Gomez, Veronica
    Miro, Manuel
    Callao, Maria Pilar
    Cerda, Victor
    ANALYTICAL CHEMISTRY, 2007, 79 (20) : 7767 - 7774