Percutaneous mitral valve repair using the edge-to-edge technique in a high-risk population

被引:19
|
作者
Van den Branden, B. J. L. [1 ]
Post, M. C. [1 ]
Swaans, M. J. [1 ]
Rensing, B. J. W. M. [1 ]
Eefting, F. D. [1 ]
Plokker, H. W. M. [1 ]
Jaarsma, W. [1 ]
Van der Heyden, J. A. S. [1 ]
机构
[1] St Antonius Hosp, Dept Cardiol, NL-3430 EM Nieuwegein, Netherlands
关键词
Mitral Valve Repair; Mitral Valve Regurgitation; High Risk; Percutaneous; REGURGITATION; HEART; SEVERITY; ANNULOPLASTY; GUIDELINES; MANAGEMENT; OUTCOMES; DISEASE;
D O I
10.1007/BF03091811
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Percutaneous mitral valve (MV) repair using the edge-to-edge clip technique might be an alternative for patients with significant mitral regurgitation (MR) and an unacceptably high risk for operative repair or replacement. We report the short-term safety and efficacy of this new technique in a high-risk population. Methods. All consecutive high-risk patients who underwent percutaneous MV repair with the Mitraclip (R) between January and August 2009 were included. All complications related to the procedure were reported. Transthoracic echo-cardiography for MR grading and right ventricular systolic pressure (RVSP) measurement were performed before, and at three and 30 days after the procedure. Differences in NYHA functional class and quality of life (QoL) index were reported. Results. Nine patients were enrolled (78% male, age 75.9 +/- 9.0 years, logistic EuroSCORE 33.8 +/- 9.0%). One patient developed inguinal bleeding. In one patient partial clip detachment occurred, a second clip was placed successfully. The MR grade before repair was >= 3 in 100%, one month after repair a reduction in MR grade to <= 2 was present in 78% (p=0.001). RVSP decreased from 43.9 +/- 12.1 to 31.6 +/- 11.7 mmHg (p=0.009), NYHA functional class improved from median 3 (range 3 to 4) to 2 (range 1 to 4) (p=0.04), and QoL index improved from 62.9 +/- 16.3 to 49.9 +/- 30.7 (p=0.12). Conclusion. In high-risk patients, transcatheter MV repair seems to be safe and a reduction in MR can be achieved in most patients, resulting in a short-term improvement of functional capacity and QoL. (Neth Heart J 2010;18:437-43.)
引用
收藏
页码:437 / 443
页数:7
相关论文
共 50 条
  • [21] Mitral stenosis is not produced by percutaneous edge-to-edge mitral valve repair of mitral regurgitation
    Rohatgi, S
    Wasserman, HS
    Block, P
    Gray, W
    Whitlow, P
    Wiegers, SE
    Sylvestry, FE
    Foster, E
    Feldman, T
    Herrmann, HC
    [J]. CIRCULATION, 2005, 112 (17) : U580 - U581
  • [22] ECG changes after percutaneous edge-to-edge mitral valve repair
    Bo, Hou
    Heinzmann, David
    Grasshoff, Christian
    Rosenberger, Peter
    Schlensak, Christian
    Gawaz, Meinrad
    Schreieck, Juergen
    Langer, Harald F.
    Patzelt, Johannes
    Seizer, Peter
    [J]. CLINICAL CARDIOLOGY, 2019, 42 (11) : 1094 - 1099
  • [23] Takotsubo syndrome after percutaneous edge-to-edge mitral valve repair
    Toselli, Marco
    Mele, Daniela
    Rizzi, Andrea
    Squeri, Angelo
    Nerla, Roberto
    Castriota, Fausto
    [J]. JOURNAL OF CARDIOVASCULAR MEDICINE, 2023, 24 (01) : 69 - 71
  • [24] Percutaneous Edge-to-Edge Mitral Valve Repair: Beyond the Left Heart
    Italia, Leonardo
    Adamo, Marianna
    Lupi, Laura
    Scodro, Marta
    Curello, Salvatore
    Metra, Marco
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2021, 34 (10) : 1038 - 1045
  • [25] Noncontrast Nephropathy After Percutaneous Mitral Valve Edge-to-Edge Repair
    Dangas, George D.
    Adams, David H.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (21) : 2474 - 2476
  • [26] Echocardiographic changes after percutaneous edge-to-edge mitral valve repair
    Koschatko, S.
    Koschutnik, M.
    Nitsche, C.
    Dona, C.
    Dannenberg, V.
    Andreas, M.
    Kammerlander, A.
    Goliasch, G.
    Bartko, P.
    Schneider, M.
    Hengstenberg, C.
    Mascherbauer, J.
    [J]. WIENER KLINISCHE WOCHENSCHRIFT, 2020, 132 : S242 - S243
  • [27] Device Thrombosis After Percutaneous Edge-to-Edge Mitral Valve Repair
    Mori, Shintaro
    Isotani, Akihiro
    Yamaji, Kyohei
    Yano, Mariko
    Morinaga, Takashi
    Hayashi, Masaomi
    Shirai, Shinichi
    Ando, Kenji
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (05) : 653 - 654
  • [28] Percutaneous Edge-to-Edge Mitral Valve Repair Using the New MitraClip XTR System
    Jorbenadze, Rezo
    Schreieck, Juergen
    Barthel, Carola
    Seizer, Peter
    Schlensak, Christian
    Gawaz, Meinrad
    Patzelt, Johannes
    Langer, Harald F.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (12) : E93 - E95
  • [29] Changes in Mitral Annular Geometry Following Percutaneous Edge-to-Edge Mitral Valve Repair Using the Mitraclip Device - New Insights in a High-Risk Patient Cohort
    Dungu, Jason
    Campos, Gabriela C.
    Jaffarulla, Rizniya
    Gomes-Pereira, Sueli
    Sutaria, Nilesh
    Baker, Christopher S.
    Nihoyannopoulos, Petros
    Bellamy, Michael
    [J]. CIRCULATION, 2011, 124 (21)
  • [30] Percutaneous Mitral Valve Edge-to-Edge Repair in Patients With Failed Mitral Annuloplasty Rings
    Verma, Divya Ratan
    Waggoner, Thomas
    Gaidici, Tony
    Muzaffar, Marium
    Distler, Edward
    Tomaiko, Emrie
    Jones, Camelle
    Centorino, Ligita
    Byrne, Timothy
    Gellert, George
    Banday, Arshad
    Unzek, Samuel
    Seethala, Srikanth
    Kalya, Aneesh
    Khurana, Bani
    Bertram, Sarah
    Taneja, Deepti
    Sugumaran, Rajkumar
    Lee, Kwan
    Goldberg, Mark
    Butman, Samuel
    Biglari, David
    Gopalan, Radha
    Naik, Hursh
    Fang, Kenith
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : B155 - B156